Products catalog

  • Axial exhaust fan with backdraft damper and timer | D120 | 190 m³/h | 230V | 182x168x69 mm | plastic | white | IPX4

    Code: ESLP22967

    Ø120 mm axial exhaust fan with automatic backdraft damper and overrun timer: 190 m³/h, 30 dB(A), 10 W, IPX4. Mounts in a wall, ceiling or duct and keeps running for the set time after the light is switched off.

  • Axial exhaust fan with backdraft damper and timer | D120 | 190 m³/h | 230V | 182x168x69 mm | plastic | white | IPX4

    Axial exhaust fan for a Ø120 mm opening with a built-in automatic backdraft damper and overrun timer. Designed to remove moisture and odours from a bathroom, toilet or other small room – after the light is switched off, the fan keeps running for a while and clears the remaining moisture.

    Key point:
    The timer solves a common bathroom problem: moisture is still in the air after the light is switched off, and the fan keeps running for the set time to extract it. When the fan stops, the backdraft damper closes the duct, so cold air and odours are not drawn in from the shaft. Rated capacity is 190 m³/h, noise level 30 dB(A).
    Mounting diameter
    Ø120 mm
    Capacity
    190 m³/h
    Noise
    30 dB(A)
    Power
    10 W

    How it works

    The fan is inserted into a Ø120 mm duct or wall opening and fixed with a flange fixing ring and mounting hooks. Supply is 230 V AC; the fan is switched on together with the light or another external switch, and after it is switched off the built-in timer keeps the fan running for the set time.

    When switched on, the impeller extracts air into the ventilation duct (up to 190 m³/h in free-air conditions, max. pressure 40 Pa). The air flow opens the backdraft damper; when the fan stops, the damper closes and blocks back-draught.

    The result is a bathroom that dries faster, a lower risk of mould and a room that does not take in cold air from the shaft while the fan is idle.

    Why choose ESLP22967?
    The fan runs together with the light and for a while after it is switched off – moisture is removed even after the person has left. The backdraft damper prevents cold air from coming back from the duct when the fan stops.

    Technical specifications

    Product type Axial exhaust fan with backdraft damper and timer
    Product code ESLP22967
    Mounting diameter Ø120 mm
    Supply voltage 230 V AC
    Power 10 W
    Air flow (capacity) 190 m³/h
    Maximum pressure 40 Pa
    Noise level 30 dB(A)
    Dimensions 182×168×69 mm
    Protection rating IPX4
    Control external switch + built-in overrun timer
    Backdraft damper built-in, closes when the fan stops
    Housing moisture-resistant plastic, white
    Mounting wall, ceiling or duct; a flange fixing ring and mounting hooks
    Motor ball-bearing

    Main functions

    • Overrun timer – after the light is switched off the fan keeps running for the set time and clears the remaining moisture.
    • Automatic backdraft damper – the duct closes when the fan stops, keeping cold air and odours out of the room.
    • 190 m³/h capacity – sufficient for air exchange in a small bathroom, toilet or storeroom.
    • 30 dB(A) noise level – suitable for living spaces.
    • IPX4 housing – protected against water splashes, suitable for damp rooms.
    • Versatile mounting – in a wall, ceiling or directly in a duct.
    • Ball-bearing motor – suitable for ceiling mounting and designed for longer service.

    How the models in this series differ

    • ESLP22968 · D120 · basic (external switch) – 190 m³/h · 40 Pa · 30 dB(A) · 10 W · 182×168×69 mm · ball-bearing motor
    • ESLP22967 · D120 · with timer – 190 m³/h · 40 Pa · 30 dB(A) · 10 W · 182×168×69 mm · ball-bearing motor – this model
    • ESLP22969 · D120 · with humidity sensor and timer – 190 m³/h · 40 Pa · 30 dB(A) · 10 W · 182×168×69 mm · ball-bearing motor
    • ESLP22970 · D120 · with pull-cord switch – 190 m³/h · 40 Pa · 30 dB(A) · 10 W · 182×168×69 mm · ball-bearing motor
    • ESLP22963 · D100 · with timer – 105 m³/h · 35 Pa · 25 dB(A) · 8.4 W · 151×151×70 mm · ball-bearing motor
    • ESLP22971 · D150 · with timer – 250 m³/h · 48 Pa · 35 dB(A) · 12 W · 212×195×81 mm · ball-bearing motor
    • ESLP22946 · D120 · with timer – 160 m³/h · 35 Pa · 30 dB(A) · 10 W · 182×168×69 mm · removable cover

    Where is it used?

    • Bathrooms and showers
    • Toilets
    • Storerooms and walk-in wardrobes
    • Basements and utility rooms
    • Laundry and drying rooms
    • Small sanitary rooms in offices and workshops
    • Country houses and seasonal homes

    Use by need

    For a family with one bathroom.
    The fan keeps running after the light is off – the next person enters an already ventilated bathroom.
    For electricians.
    Standard Ø120 mm diameter and 230 V connection according to the timer diagram – the fan is controlled by the same light switch.
    For landlords.
    Ventilation does not depend on whether the tenant remembers to leave the fan on – the timer does it automatically.

    Practical use

    If a bathroom measures 2.0 × 2.5 m with a 2.5 m ceiling (about 12.5 m³), the rated flow of 190 m³/h would theoretically change the air about 15 times per hour. In practice the flow will be lower due to duct length, bends and grilles, so for a long or winding duct a higher-capacity model of this series is worth choosing.

    Pros

    • Timer – keeps ventilating after the light is off
    • Built-in automatic backdraft damper
    • Quiet operation – 30 dB(A)
    • Low consumption – 10 W
    • Wall, ceiling or duct mounting
    • IPX4 splash protection
    • Ball-bearing motor – suitable for ceiling mounting

    Cons / limitations

    • No humidity sensor – does not switch on automatically by humidity
    • The timer run-on time is not stated in the supplier data
    • The rated 190 m³/h flow is given without duct resistance; in a long duct it is lower
    • Designed for small and medium rooms, not for central ventilation systems
    • No heat recovery – room air is exhausted

    Safety and installation notes

    • Disconnect the power before installation and make sure the circuit is de-energised.
    • Protect the bathroom circuit with a 30 mA residual current device (RCD).
    • IPX4 means splash protection, not immersion: do not install directly above a bath or shower tray (zone 0) and follow the zone requirements of HD 60364-7-701.
    • Make sure the backdraft damper opens and closes freely – the duct or sealant must not press on it.
    • For the timer to work after the switch is turned off, the fan needs a permanent supply – connect it exactly according to the diagram in the product instructions.
    • Mains installation must be carried out by a qualified electrician.

    Quick selection guide

    Ø120 mm
    190 m³/h
    30 dB(A)
    10 W
    IPX4
    Timer
    Suitable when you need:
    • To ventilate the bathroom after the light is switched off
    • To control the fan with the same light switch
    • To stop cold air coming back from the duct
    Check before use:
    • Whether the duct or opening diameter is Ø120 mm
    • Whether there is room for the 182×168×69 mm housing
    • Whether a 230 V supply is available at the opening
    • Whether the room has an air inlet path (gap under the door or a grille)
    • Whether the wiring at the fan matches the product connection diagram (permanent supply and switched control)
    Important reminder: The fan does not replace continuous mechanical ventilation or a heat recovery unit – it extracts air only while running.

    FAQ

    How does the timer work?
    After the light or another switch is turned off, the fan keeps running for the set time and ventilates the room.
    What is the backdraft damper for?
    When the fan stops it closes the duct so that cold air and odours do not enter the room.
    What duct diameter does ESLP22967 fit?
    A Ø120 mm duct or wall opening.
    Can it be mounted in the ceiling?
    Yes, the fan can be mounted in a wall, ceiling or duct.
    Does it switch on by humidity?
    No, for automatic switching by humidity choose the version in the same housing with a humidity sensor (ESLP22969).
    Is it suitable for a bathroom?
    Yes, the housing is IPX4, but install it outside zone 0 and protect the circuit with a 30 mA RCD.

    Axial exhaust fan with backdraft damper and timer | D120 | 190 m³/h | 230V | 182x168x69 mm | plastic | white | IPX4

    ESLP22967 is a Ø120 mm axial exhaust fan with an automatic backdraft damper and overrun timer: 190 m³/h, 30 dB(A), 10 W, IPX4. Designed for bathrooms, toilets and other small rooms where ventilation is needed after the light is switched off.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Supply air ventilation damper in the wall | with filter | mineral wool thermal insulation with foil | D125 | 0,45m | white | 12,5TOV045-01
    Code: 23041

    Wall supply air valve Ø125 mm / 450 mm with filter, non-return valve and foil-faced mineral wool insulation. Restores fresh air supply in apartments, houses and offices, dampens street noise, while the foil protects the wool from moisture and dust.

    Price 31.45 € VAT incl.
    ( 25.99 € VAT excl. )
    Shut-off damper for round air duct | for ventilation | air handling systems | D100 | silver | galvanized steel | 100USO
    Code: 04963

    Round duct shut-off damper, designed to shut off, restrict, or regulate airflow in round air ducts. The damper is used in supply, exhaust, or recirculation air systems where simple and efficient control of air movement within premises is required.

    Due to its galvanized steel construction, the product is resistant to corrosion, durable, and suitable for use in residential, commercial, and technical ventilation systems. Manual operation allows easy airflow adjustment without the need for an additional electric actuator or automation system. 

    Price 6.50 € VAT incl.
    ( 5.37 € VAT excl. )
    Flexible aluminum air duct | for ventilation | ventilation systems | D100mm | 3m | white | LAO100B
    Code: 23033

    Flexible aluminium air duct - a reliable and universal solution for professional and residential ventilation systems. Designed to connect ventilation elements, fans, heat recovery components or other air distribution units.

    Due to its low weight, high flexibility and resistance to high temperatures, the duct ensures quick installation, tightness and long-term operation even in more demanding conditions. The white surface blends aesthetically in technical and visible installation areas. 

    Price 7.20 € VAT incl.
    ( 5.95 € VAT excl. )
    Duct centrifugal fan | D125 | 370 m³/h | 52 W | 230 V | 310 Pa | plastic housing | white | 15622
    Code: 15622

    Duct centrifugal fan 15622: D125, up to 370 m³/h, 310 Pa, 52 W, 230 V, plastic housing.

    Price 93.17 € VAT incl.
    ( 77.00 € VAT excl. )
  • privacy policy

    Information