  • Wall-mounted CO2 | temperature | humidity controller for ventilation | 2×0-10 V | relay | 350-1999 ppm | RS485 Modbus | 95-240 VAC | IP30 | ES-900A-Y2DC

    Code: ES-900A-Y2DC

    Wall-mounted CO2, temperature and humidity controller for demand-controlled ventilation: 2 × 0-10 V outputs for supply and exhaust fans, NO/NC relay, RS485 Modbus, 95-240 VAC supply, IP30.

  • Wall-mounted CO2 | temperature | humidity controller for ventilation | 2×0-10 V | relay | 350-1999 ppm | RS485 Modbus | 95-240 VAC | IP30 | ES-900A-Y2DC

    ES-900A-Y2DC is a wall-mounted indoor air quality controller: it measures CO2 concentration, temperature and humidity and controls ventilation according to the CO2 level. Two 0-10 V outputs drive the supply and exhaust fans, and an NO/NC relay contact switches a damper or valve. It is powered directly from 95-240 VAC mains and connects to a building management system via RS485 (Modbus).

    Key point:
    Ventilation at a fixed speed is too weak during a meeting and wastes heat in an empty room. This controller speeds the fans up when CO2 rises and slows them down when the air is clean. It is a simple way to move to demand-controlled ventilation without a separate sensor, speed controller and room panel.
    Control
    2 × 0-10 V + NO/NC relay
    CO2 display
    350-1999 ppm (control 350-1500 ppm)
    Power supply
    95-240 VAC, 50/60 Hz
    Communication
    RS485 (Modbus)

    Operating principle

    The controller is mounted on the wall over a flush-mounted box (fixing hole spacing 60 mm). Terminals 1-2 – power N and L, 3-4 – relay NO/NC outputs (switched live L), 5-6 – 0-10 V signals for the supply and exhaust fans, 7 – common GND, 8-9 – RS485 line B/A.

    After power-up the sensor needs at least 2 min to warm up; response time is up to 10 s. In automatic mode the controller compares the measured CO2 with the set threshold (within 350-1500 ppm) and adjusts the 0-10 V signal: as air quality drops, the fans run faster. Manual mode with low, medium or high speed and a timer are also available.

    The result: CO2, temperature, humidity and time are shown on the display, ventilation follows actual room occupancy, and settings are retained after a power failure.

    Why choose ES-900A-Y2DC?
    One device does the job of three: it measures air quality, controls fan speed and serves as a room panel. No separate 24 V power supply is needed – a 230 V line at the mounting box is enough.

    Technical specifications

    Product type Wall-mounted CO2, temperature and humidity meter-controller for ventilation systems
    Manufacturer Elsp Group
    Code ES-900A-Y2DC
    Supply voltage 95-240 VAC, 50/60 Hz
    Rated power < 2 W
    CO2 display range 350-1999 ppm
    CO2 control range 350-1500 ppm
    Temperature display 0…+99 °C
    Humidity display 5-90 % RH
    Sensor warm-up time ≥ 2 min
    Response time ≤ 10 s
    Analogue outputs 2 × 0-10 V (supply and exhaust fans), common GND
    Relay output NO / NC, switched live L
    Controlled load ≤ 200 W
    Communication interface RS485 (A/B), Modbus
    Control modes Automatic (by CO2), manual (low / medium / high speed), timer
    Display LCD with touch buttons
    Terminals 9: N, L, NO, NC, 0-10 V ×2, GND, B, A
    Wire cross-section 2 × 1.5 mm² or 1 × 2.5 mm²
    Mounting On the wall, over a flush-mounted box; fixing hole spacing 60 mm
    Dimensions Front part 88 × 88 × 15 mm, rear part 65 × 63 × 35 mm
    Protection rating IP30
    Housing flammability class V0

    Main functions

    • 0-10 V control based on CO2 – in automatic mode the 0-10 V output signal is changed according to the measured CO2 level; the control behaviour depends on the controller's parameter settings.
    • Two 0-10 V outputs – supply and exhaust fans, EC motors or frequency inverters with a 0-10 V input are connected separately.
    • NO/NC relay output – opens a fresh air damper or valve together with ventilation.
    • Three modes – automatic, manual with 3 speeds and timer – the user can temporarily take over control.
    • RS485 / Modbus – readings and control are passed to a BMS, PLC or SCADA system.
    • Filter reminder – signals when it is time to replace the ventilation unit filter.
    • Settings memory and display saving – no reprogramming after a power cut, and the dimmed display does not disturb in a bedroom.

    Where is it used?

    • Office meeting rooms and open-plan workspaces
    • School classrooms and kindergarten groups
    • Apartments and houses with heat recovery units that have a 0-10 V control input
    • Sports halls and fitness clubs
    • Restaurant and café dining rooms
    • Hotel conference rooms
    • Staff and rest rooms in production facilities

    Use by need

    For the ventilation installer.
    One 230 V powered device replaces the sensor, speed controller and room panel, so there are fewer components and cables on site.
    For the BMS / automation integrator.
    Via the RS485 line, CO2, temperature and humidity can be read into the building management system and ventilation controlled centrally.
    For the office or school facility manager.
    Ventilation increases only when people are in the room, so the air stays fresh and heating costs do not rise for nothing.

    Practical application

    If the heat recovery unit in a meeting room runs at a fixed speed and the air gets stuffy during longer meetings, then ES-900A-Y2DC is mounted on an inner wall at about 1.5 m height, its 0-10 V outputs are connected to the control inputs of the supply and exhaust fans, and a CO2 threshold is set, for example 800 ppm. When people gather, the fans speed up automatically, and when the room empties they return to minimum mode.

    Pros

    • Powered directly from 95-240 VAC – no 24 V power supply needed
    • Two 0-10 V outputs and a relay in one housing
    • CO2, temperature and humidity on one display
    • RS485 / Modbus for BMS integration
    • Fits over a flush-mounted box, front part only 15 mm
    • Low own consumption (< 2 W), V0 flammability class housing

    Cons / limitations

    • 0-10 V outputs are a control signal only: the fan or inverter must have a 0-10 V input; 3-speed AC fans cannot be controlled directly
    • CO2 display up to 1999 ppm, control up to 1500 ppm – for greenhouses or process CO2 control choose a sensor with a 0-5000 ppm range
    • IP30 – for dry indoor rooms only
    • The Modbus register map is not included in the description – check it with us before integration
    • No Wi-Fi or app – remote control only via RS485

    Safety and installation notes

    • Wiring must be done by a qualified electrician with the power switched off.
    • Do not mix up the terminals: 95-240 VAC is connected only to N and L (1-2). Mains voltage on the 0-10 V, GND or RS485 terminals will destroy the controller and the connected equipment.
    • The relay NO/NC terminals switch the live conductor – do not exceed 200 W; use an interposing relay or contactor for larger loads.
    • Mount at about 1.5 m on an inner wall: not near doors, windows, supply air diffusers, heaters or direct sunlight, and not where people breathe directly onto the sensor.
    • Run the RS485 line with shielded twisted pair cable, separately from 230 V cables; fit 120 Ω termination resistors at the line ends.
    • Connect the 0-10 V signal GND to the signal zero of the controlled device.
    • After power-up wait at least 2 min for the sensor to warm up before judging readings or adjusting settings.

    Quick selection guide

    350-1999 ppm
    2 × 0-10 V + NO/NC
    95-240 VAC
    RS485 Modbus
    IP30
    88 × 88 mm
    Suitable when you need to:
    • control a heat recovery unit or EC fans by CO2 level
    • see CO2, temperature and humidity in the room
    • send air quality data to a BMS via RS485
    Check before use:
    • whether the fan or heat recovery unit has a 0-10 V control input
    • whether there is a 230 V line and a flush-mounted box at the mounting point
    • whether the BMS supports Modbus over RS485 (check the register map)
    • whether the relay load does not exceed 200 W
    Important reminder: this is a ventilation controller, not a calibrated measuring instrument and not a safety gas detector – it does not detect carbon monoxide (CO) and does not replace fire or gas alarms.

    FAQ

    What is the supply voltage?
    95-240 VAC, 50/60 Hz, connected to the N and L terminals.
    Can it control two fans?
    Yes, there are two 0-10 V outputs – for the supply and exhaust fans.
    Will it suit my heat recovery unit?
    Yes, if the unit or its fans accept a 0-10 V speed control signal.
    Does the controller support Modbus?
    Yes, communication runs via the RS485 interface (terminals A/B); the register map is provided on request.
    Can it be installed in a bathroom?
    No, the IP30 housing is intended for dry indoor rooms only.
    Are settings retained after a power cut?
    Yes, the controller has a settings memory function.

    Wall-mounted CO2 | temperature | humidity controller for ventilation | 2×0-10 V | relay | 350-1999 ppm | RS485 Modbus | 95-240 VAC | IP30 | ES-900A-Y2DC

    ES-900A-Y2DC is a wall-mounted CO2, temperature and humidity controller with two 0-10 V outputs, an NO/NC relay and an RS485 Modbus interface, powered by 95-240 VAC. Designed for demand-controlled ventilation in offices, schools and homes with heat recovery units.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information