Cable 3x1.5 mm² | copper | solid | halogen-free | NHXMH-J 3x1.5 | 1 m | white
Code: 9203150113Halogen-free NHXMH-J 3×1.5 mm² installation cable, 300/500 V, CPR Cca-s1a,d1,a1. Sold by the metre, minimum order 10 m.
-
Cable 3x1.5 mm² | copper | solid | halogen-free | NHXMH-J 3x1.5 | 1 m | white
NHXMH-J is a halogen-free installation cable with solid copper conductors for fixed electrical installations in buildings. This 3-core 1.5 mm² version is intended for single-phase circuits (L, N, PE), most often lighting, control and lower-power circuits. When burning, the cable releases no halogens or corrosive gases and produces little smoke – which is why it is chosen wherever safe evacuation and equipment protection matter.
Key idea:
A standard PVC cable gives off thick black smoke and hydrogen chloride in a fire, which turns into hydrochloric acid on contact with moisture. The NHXMH-J sheath is made of a halogen-free LSOH compound: less smoke, escape routes stay visible longer, and electronics and building structures suffer less corrosion. It is installed just like NYM-J, only with a higher level of fire safety.Rated voltage
300/500 VConductors
3 × 1.5 mm², solid CuFire class (CPR)
Cca-s1a,d1,a1Conductor temperature
up to +70 °CDesign and operating principle
Each core is a solid annealed copper wire (class 1 to IEC 60228) insulated with a cross-linked polymer. The cores are laid up together and covered with a white halogen-free thermoplastic outer sheath.
The “-J” designation means the cable contains a green-yellow protective (PE) core. Core colours to HD 308 S2: brown (L), blue (N), green-yellow (PE).
The sheath contains no PVC, so no chlorine or other halogens are released when it burns. The cable’s CPR fire class is Cca-s1a,d1,a1: limited flame spread, low smoke production (s1a), short-lived flaming droplets (d1) and low-acidity combustion gases (a1).
Why choose NHXMH-J?
The first minutes of a fire are the most critical. Less smoke means better visibility on escape routes, and no halogens means less harm to people’s airways, server equipment and building structures.Technical specifications
Product type Halogen-free sheathed installation cable Designation NHXMH-J 3G1.5 (3 × 1.5 mm²) Manufacturer AB Lietkabelis (Lithuania) Conductor Annealed copper wire, solid, class 1 (IEC 60228) Core insulation Cross-linked polymer Core colours brown (L), blue (N), green-yellow (PE) (HD 308 S2) Sheath Halogen-free thermoplastic compound (LSOH), white Rated voltage U₀/U 300/500 V Test voltage 2000 V Max. conductor operating temperature +70 °C Ambient temperature (fixed installation) −30 °C … +70 °C Installation temperature not below +5 °C Minimum bending radius 4 × cable outer diameter Fire class (CPR, EN 13501-6) Cca-s1a,d1,a1 Combustion products Halogen-free (EN 60754-1/-2), low smoke density (EN 61034-2) Construction type NHXMH to DIN VDE 0250-214 Sales unit 1 m, minimum order 10 m CPR class, voltage and materials are data declared by the manufacturer; temperatures and bending radius are standard values for NHXMH-type cables. Measure the actual cable diameter before selecting cable glands.
Key features
- Halogen-free – no chlorine or corrosive gases that damage electronics and metal structures are released when it burns.
- Low smoke (s1a) – escape routes stay visible longer, making rescue work easier.
- Limited flame spread – CPR class Cca suits projects that require a Cca, Dca or Eca class cable.
- Solid copper conductors – clamp securely in terminals, no ferrules needed.
- Green-yellow PE core – protective earthing is carried in the same cable.
- Cross-linked core insulation – resistant to heat and mechanical pressure at terminal points.
- Versatile installation – on, under and in plaster, in masonry and concrete (not vibrated or tamped), in cable trays and conduits.
- White sheath – looks neat in surface installations in light-coloured rooms.
- Lithuanian manufacturer – an AB Lietkabelis product with a CPR declaration of performance.
- Sold by the metre – buy exactly what the project needs (from 10 m).
Where is it used?
- Schools, kindergartens, universities
- Hospitals, clinics, care homes
- Shopping and leisure centres, hotels, offices
- Escape routes, staircases and corridors
- Airports, stations, underground car parks
- Server rooms, data centres, control rooms
- Apartment buildings and private houses where higher fire safety is wanted
- Museums, archives, libraries – where corrosive gases endanger valuable items
Use by need
For electrical contractors.
When the design specifies halogen-free wiring or class Cca, NHXMH-J is installed with the same tools and terminals as NYM-J – no change in working method.For designers.
A halogen-free cable with a declared CPR class Cca-s1a,d1,a1 – easier to justify in the fire safety section of the design.For homeowners.
In children’s rooms, bedrooms and next to the boiler room, a halogen-free cable reduces the risk of smoke and toxic gases in a fire.Practical application
An NHXMH-J 3 × 1.5 mm² cable is run for a school corridor lighting circuit: brown core – phase L, blue – neutral N, green-yellow – PE. The cable is fixed in a cable tray above the suspended ceiling, and the circuit is protected by a circuit breaker as designed (usually B10 for lighting).Pros
- Halogen-free, low smoke
- CPR class Cca-s1a,d1,a1
- Solid Cu conductors – reliable terminal contact
- With green-yellow PE core
- Installed on and under plaster, in masonry and concrete
- Made in Lithuania
Cons / limitations
- More expensive than PVC cable NYM-J (KH05VV-U)
- Solid conductors – not suitable for moving or flexible connections
- Not fire-resistant (not E30/E90) – does not replace cables for fire safety systems
- Outdoors only when protected from direct sunlight
- Do not lay directly in the ground or in vibrated or tamped concrete
- Install at temperatures not below +5 °C
Safety and installation notes
- Installation and connection must be carried out by a qualified electrician with the power disconnected.
- The cable cross-section and protective device are selected by the designer based on load, installation method, circuit length and voltage drop (IEC 60364-5-52).
- Do not bend the cable to a radius smaller than 4 times its diameter – the core insulation may be damaged.
- In cold weather, keep the cable in a warm room before installation – lay it at temperatures not below +5 °C.
- The green-yellow core is used only as the protective PE conductor, the blue core only as neutral N.
- Outdoors and in sunny locations, protect the cable from direct sunlight with a conduit or trunking.
- Use halogen-free boxes, conduits and trunking for a halogen-free line too – PVC accessories reduce the fire safety benefit.
Quick selection guide
300/500 V3 × 1.5 mm²Cca-s1a,d1,a1LSOH, halogen-freeWhite sheathSuitable when you need:- a halogen-free cable in a public or higher fire-risk building;
- 3 cores – single-phase circuits (L, N, PE);
- 1.5 mm² – lighting, control and lower-power circuits.
Check before buying:- that the design does not require a class higher than Cca (e.g. B2ca);
- that 1.5 mm² is sufficient for the load and circuit length;
- that the circuit does not need a fire-resistant cable (fire alarm, emergency lighting, smoke extraction);
- that boxes, conduits and trunking are also halogen-free.
Important reminder: For 1.5 mm² circuits, a B10 circuit breaker is most commonly used (lighting), and B16 for some installation methods. The final decision is made by the designer.⚠ Attention: the circuit breaker ratings are given as indicative recommendations only. The final selection is made by the designer or a qualified electrician based on installation method, ambient temperature, circuit length and voltage drop. UAB Elektrotechnikos sprendimai accepts no liability for incorrect selection, installation or resulting errors.FAQ
How does NHXMH-J differ from NYM-J (KH05VV-U)?
Design and installation are similar, but the NYM-J sheath is PVC, while NHXMH-J uses a halogen-free LSOH compound. In a fire, NHXMH-J produces less smoke and releases no corrosive halogen gases.Is NHXMH-J a fire-resistant cable?
No. A halogen-free cable limits flame spread and smoke but does not maintain circuit integrity in a fire. Fire safety systems require fire-resistant cables with a circuit integrity class (e.g. E30, E90).What does Cca-s1a,d1,a1 mean?
It is the CPR fire class (EN 13501-6): Cca – flame spread and heat release class, s1a – lowest smoke production, d1 – flaming droplets or particles persist no longer than 10 s, a1 – low-acidity combustion gases.Can it be laid in concrete and outdoors?
It can be laid in plaster, masonry and concrete, except vibrated or tamped concrete. Outdoors – only when protected from direct sunlight, e.g. in a conduit or trunking. It must not be buried directly in the ground.Which circuit breaker should be used with a 1.5 mm² cable?
For 1.5 mm² circuits, a B10 circuit breaker is most commonly used (lighting), and B16 for some installation methods. The final decision is made by the designer. For long circuits, the voltage drop must be checked.How is the cable sold?
The price is per 1 m, minimum order quantity 10 m. For larger quantities (coils, drums) we will prepare an individual offer.Halogen-free cable NHXMH-J 3 × 1.5 mm²
NHXMH-J 3 × 1.5 mm² – a halogen-free installation cable by Lietkabelis with solid copper conductors, 300/500 V and CPR class Cca-s1a,d1,a1. Suitable for public buildings, escape routes and anywhere less smoke and no halogens matter in a fire. Need a larger quantity or all the cables for a project? We will prepare an offer.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerSingle-core wires are also called monolithic wires,
while multi-core wires are flexible wires.Wires usually have a single conductor covered with an insulating layer.
Cables have several insulated wires, covered with a common sheath.
Conductor properties of wires:
The resistance of copper conductors is lower (0.017Ω) than that of aluminum (0.028Ω),
but copper has better conductivity.
Copper has better electrical and thermal conductivity than aluminum.
Copper wires are more flexible, more resistant to corrosion, and more durable.
Aluminum wires quickly oxidize upon contact with air, forming a film that weakens the contact.
Copper wires carry higher currents than aluminum wires.
Copper conductors are denser than aluminum. Therefore, copper wire is heavier.The cross-sectional area of wires is chosen according to the power of specific equipment,
for example: for a 1kW load, a 1.57 mm² cross-sectional area of the conductor is required.
For aluminum wires: 5A per 1mm², and for copper wires: 8A per 1mm².Fire-Resistant and Non-Flammable Cables
Description: Standard PVC (polyvinyl chloride) cables release toxic gases and a thick black smoke screen during a fire, which complicates the work of firefighters when searching through buildings. Burning PVC emits highly acidic hydrogen chloride gases (HCl), which, when mixed with water, turn into hydrochloric acid. Inhaling these gases can severely irritate the respiratory system, and contact with eyes or skin can cause serious burns. Additionally, HCl can irreparably damage electrical equipment.Halogen-free cables are an alternative that do not release halogens (chlorine) and provide greater safety since these cables do not produce corrosive smoke.
Non-flammable cables are designed to prevent flames from spreading along the cable's surface during a fire. These cables ensure the continued operation of fire safety systems, such as lighting, smoke removal, fire sprinklers, etc., for a certain period during a fire.
Fire Resistance Classification: Fire resistance of cables is categorized into seven safety classes from A to F:
A – Non-flammable product.
F – No reaction to fire specified.
Most cables fall into categories B, C, D, and E.Additional Safety Criteria for Cables:
Smoke Emission (s1, s2, s3) – Lower values indicate less smoke.
Flaming Droplets (d1, d2, d3) – Lower values indicate no flaming droplets are produced.
Smoke Acidity and Electrolytic Conductivity (a1, a2, a3) – Lower values mean less hazardous smoke.
Cable Marking:D – Fire resistance class
ca – Cables/wires
s – Smoke emission
d – Flaming droplets
a – Smoke acidity and conductivity
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products