  • Cable 3x1.5 mm² | copper | solid | halogen-free | NHXMH-J 3x1.5 | 1 m | white

    Code: 9203150113

    Halogen-free NHXMH-J 3×1.5 mm² installation cable, 300/500 V, CPR Cca-s1a,d1,a1. Sold by the metre, minimum order 10 m.

  • Cable 3x1.5 mm² | copper | solid | halogen-free | NHXMH-J 3x1.5 | 1 m | white

    NHXMH-J is a halogen-free installation cable with solid copper conductors for fixed electrical installations in buildings. This 3-core 1.5 mm² version is intended for single-phase circuits (L, N, PE), most often lighting, control and lower-power circuits. When burning, the cable releases no halogens or corrosive gases and produces little smoke – which is why it is chosen wherever safe evacuation and equipment protection matter.

    Key idea:
    A standard PVC cable gives off thick black smoke and hydrogen chloride in a fire, which turns into hydrochloric acid on contact with moisture. The NHXMH-J sheath is made of a halogen-free LSOH compound: less smoke, escape routes stay visible longer, and electronics and building structures suffer less corrosion. It is installed just like NYM-J, only with a higher level of fire safety.
    Rated voltage
    300/500 V
    Conductors
    3 × 1.5 mm², solid Cu
    Fire class (CPR)
    Cca-s1a,d1,a1
    Conductor temperature
    up to +70 °C

    Design and operating principle

    Each core is a solid annealed copper wire (class 1 to IEC 60228) insulated with a cross-linked polymer. The cores are laid up together and covered with a white halogen-free thermoplastic outer sheath.

    The “-J” designation means the cable contains a green-yellow protective (PE) core. Core colours to HD 308 S2: brown (L), blue (N), green-yellow (PE).

    The sheath contains no PVC, so no chlorine or other halogens are released when it burns. The cable’s CPR fire class is Cca-s1a,d1,a1: limited flame spread, low smoke production (s1a), short-lived flaming droplets (d1) and low-acidity combustion gases (a1).

    Why choose NHXMH-J?
    The first minutes of a fire are the most critical. Less smoke means better visibility on escape routes, and no halogens means less harm to people’s airways, server equipment and building structures.

    Technical specifications

    Product type Halogen-free sheathed installation cable
    Designation NHXMH-J 3G1.5 (3 × 1.5 mm²)
    Manufacturer AB Lietkabelis (Lithuania)
    Conductor Annealed copper wire, solid, class 1 (IEC 60228)
    Core insulation Cross-linked polymer
    Core colours brown (L), blue (N), green-yellow (PE) (HD 308 S2)
    Sheath Halogen-free thermoplastic compound (LSOH), white
    Rated voltage U₀/U 300/500 V
    Test voltage 2000 V
    Max. conductor operating temperature +70 °C
    Ambient temperature (fixed installation) −30 °C … +70 °C
    Installation temperature not below +5 °C
    Minimum bending radius 4 × cable outer diameter
    Fire class (CPR, EN 13501-6) Cca-s1a,d1,a1
    Combustion products Halogen-free (EN 60754-1/-2), low smoke density (EN 61034-2)
    Construction type NHXMH to DIN VDE 0250-214
    Sales unit 1 m, minimum order 10 m

    CPR class, voltage and materials are data declared by the manufacturer; temperatures and bending radius are standard values for NHXMH-type cables. Measure the actual cable diameter before selecting cable glands.

    Key features

    • Halogen-free – no chlorine or corrosive gases that damage electronics and metal structures are released when it burns.
    • Low smoke (s1a) – escape routes stay visible longer, making rescue work easier.
    • Limited flame spread – CPR class Cca suits projects that require a Cca, Dca or Eca class cable.
    • Solid copper conductors – clamp securely in terminals, no ferrules needed.
    • Green-yellow PE core – protective earthing is carried in the same cable.
    • Cross-linked core insulation – resistant to heat and mechanical pressure at terminal points.
    • Versatile installation – on, under and in plaster, in masonry and concrete (not vibrated or tamped), in cable trays and conduits.
    • White sheath – looks neat in surface installations in light-coloured rooms.
    • Lithuanian manufacturer – an AB Lietkabelis product with a CPR declaration of performance.
    • Sold by the metre – buy exactly what the project needs (from 10 m).

    Where is it used?

    • Schools, kindergartens, universities
    • Hospitals, clinics, care homes
    • Shopping and leisure centres, hotels, offices
    • Escape routes, staircases and corridors
    • Airports, stations, underground car parks
    • Server rooms, data centres, control rooms
    • Apartment buildings and private houses where higher fire safety is wanted
    • Museums, archives, libraries – where corrosive gases endanger valuable items

    Use by need

    For electrical contractors.
    When the design specifies halogen-free wiring or class Cca, NHXMH-J is installed with the same tools and terminals as NYM-J – no change in working method.
    For designers.
    A halogen-free cable with a declared CPR class Cca-s1a,d1,a1 – easier to justify in the fire safety section of the design.
    For homeowners.
    In children’s rooms, bedrooms and next to the boiler room, a halogen-free cable reduces the risk of smoke and toxic gases in a fire.

    Practical application

    An NHXMH-J 3 × 1.5 mm² cable is run for a school corridor lighting circuit: brown core – phase L, blue – neutral N, green-yellow – PE. The cable is fixed in a cable tray above the suspended ceiling, and the circuit is protected by a circuit breaker as designed (usually B10 for lighting).

    Pros

    • Halogen-free, low smoke
    • CPR class Cca-s1a,d1,a1
    • Solid Cu conductors – reliable terminal contact
    • With green-yellow PE core
    • Installed on and under plaster, in masonry and concrete
    • Made in Lithuania

    Cons / limitations

    • More expensive than PVC cable NYM-J (KH05VV-U)
    • Solid conductors – not suitable for moving or flexible connections
    • Not fire-resistant (not E30/E90) – does not replace cables for fire safety systems
    • Outdoors only when protected from direct sunlight
    • Do not lay directly in the ground or in vibrated or tamped concrete
    • Install at temperatures not below +5 °C

    Safety and installation notes

    • Installation and connection must be carried out by a qualified electrician with the power disconnected.
    • The cable cross-section and protective device are selected by the designer based on load, installation method, circuit length and voltage drop (IEC 60364-5-52).
    • Do not bend the cable to a radius smaller than 4 times its diameter – the core insulation may be damaged.
    • In cold weather, keep the cable in a warm room before installation – lay it at temperatures not below +5 °C.
    • The green-yellow core is used only as the protective PE conductor, the blue core only as neutral N.
    • Outdoors and in sunny locations, protect the cable from direct sunlight with a conduit or trunking.
    • Use halogen-free boxes, conduits and trunking for a halogen-free line too – PVC accessories reduce the fire safety benefit.

    Quick selection guide

    300/500 V
    3 × 1.5 mm²
    Cca-s1a,d1,a1
    LSOH, halogen-free
    White sheath
    Suitable when you need:
    • a halogen-free cable in a public or higher fire-risk building;
    • 3 cores – single-phase circuits (L, N, PE);
    • 1.5 mm² – lighting, control and lower-power circuits.
    Check before buying:
    • that the design does not require a class higher than Cca (e.g. B2ca);
    • that 1.5 mm² is sufficient for the load and circuit length;
    • that the circuit does not need a fire-resistant cable (fire alarm, emergency lighting, smoke extraction);
    • that boxes, conduits and trunking are also halogen-free.
    Important reminder: For 1.5 mm² circuits, a B10 circuit breaker is most commonly used (lighting), and B16 for some installation methods. The final decision is made by the designer.
    ⚠ Attention: the circuit breaker ratings are given as indicative recommendations only. The final selection is made by the designer or a qualified electrician based on installation method, ambient temperature, circuit length and voltage drop. UAB Elektrotechnikos sprendimai accepts no liability for incorrect selection, installation or resulting errors.

    FAQ

    How does NHXMH-J differ from NYM-J (KH05VV-U)?
    Design and installation are similar, but the NYM-J sheath is PVC, while NHXMH-J uses a halogen-free LSOH compound. In a fire, NHXMH-J produces less smoke and releases no corrosive halogen gases.
    Is NHXMH-J a fire-resistant cable?
    No. A halogen-free cable limits flame spread and smoke but does not maintain circuit integrity in a fire. Fire safety systems require fire-resistant cables with a circuit integrity class (e.g. E30, E90).
    What does Cca-s1a,d1,a1 mean?
    It is the CPR fire class (EN 13501-6): Cca – flame spread and heat release class, s1a – lowest smoke production, d1 – flaming droplets or particles persist no longer than 10 s, a1 – low-acidity combustion gases.
    Can it be laid in concrete and outdoors?
    It can be laid in plaster, masonry and concrete, except vibrated or tamped concrete. Outdoors – only when protected from direct sunlight, e.g. in a conduit or trunking. It must not be buried directly in the ground.
    Which circuit breaker should be used with a 1.5 mm² cable?
    For 1.5 mm² circuits, a B10 circuit breaker is most commonly used (lighting), and B16 for some installation methods. The final decision is made by the designer. For long circuits, the voltage drop must be checked.
    How is the cable sold?
    The price is per 1 m, minimum order quantity 10 m. For larger quantities (coils, drums) we will prepare an individual offer.

    Halogen-free cable NHXMH-J 3 × 1.5 mm²

    NHXMH-J 3 × 1.5 mm² – a halogen-free installation cable by Lietkabelis with solid copper conductors, 300/500 V and CPR class Cca-s1a,d1,a1. Suitable for public buildings, escape routes and anywhere less smoke and no halogens matter in a fire. Need a larger quantity or all the cables for a project? We will prepare an offer.