Copper installation cable NYM-J | 5×10 mm² | 300/500 V | white | 1 m | Lietkabelis KH05VV-U 5G10
Code: KH05VV-U 5G10NYM-J 5×10 mm² (KH05VV-U 5G10) – AB Lietkabelis copper installation cable with solid class 1 conductors, PVC insulation and a white PVC sheath, 300/500 V. For fixed installation inside buildings: in walls, under plaster, in conduits and trunking. Sold by the metre.
5 cores (L1, L2, L3, N, PE) for three-phase 400 V installation with neutral: three-phase sockets, cookers, sub-boards and mixed loads.
-
Copper installation cable NYM-J | 5×10 mm² | 300/500 V | white | 1 m | Lietkabelis KH05VV-U 5G10
NYM-J 5×10 mm² – white copper cable with 5 solid conductors (L1, L2, L3, N, PE) for fixed electrical installation inside buildings. Manufacturer – AB Lietkabelis, designation KH05VV-U 5G10, rated voltage 300/500 V.
Key point:
A five-core cable is the universal three-phase solution: three phases, neutral N and protective PE. It suits both three-phase and mixed (three-phase + single-phase) loads.Number of cores
5 (L1, L2, L3, N, PE)Cross-section
10 mm²Typical protection
40 A circuit breakerInstallation
IndoorsHow it works
The cable is installed permanently: in walls, under plaster, in conduits or trunking from the board to the load. Cores are connected by colour: L1, L2, L3, N, PE.
Solid 10 mm² copper conductors carry the current, while PVC insulation and the white sheath protect them mechanically and electrically. The continuous conductor temperature is up to +70 °C, so the current rating depends on how well the cable dissipates heat.
With the right protection (40 A) and length (up to ≈ 75 m at 40 A), the circuit runs for years without overheating and the voltage drop stays within 3 %.
Why choose NYM-J 5×10 mm²?
It is a simple, reliable solution for a circuit where three-phase 400 V with neutral is needed: solid conductors are easy to terminate, the white sheath looks neat on surfaces, and you buy exactly as many metres as you need.Technical data
Product type Copper installation cable NYM-J Manufacturer AB „Lietkabelis“ – KH05VV-U 5G10 Number of cores 5 (L1, L2, L3, N, PE) Cross-section per core 10 mm² Conductor Solid (class 1) annealed copper Insulation / sheath PVC / white PVC Rated voltage 300/500 V Conductor temperature Up to +70 °C continuous, up to +160 °C during a short circuit Ambient temperature In service −30…+70 °C, installation −5…+40 °C Minimum bending radius ≥ 5 × cable diameter Cable diameter (manufacturer data) 17.57 mm Current rating (indicative) about 46–57 A to IEC 60364-5-52 (3 loaded cores, +30 °C, installation methods B2–C) Typical protection 40 A circuit breaker – up to ~27.7 kW (three-phase 400 V with neutral, cos φ = 1) Circuit length (ΔU ≤ 3 %) up to ≈ 75 m at 40 A load Installation Indoors: in walls, under plaster, in conduits, trunking, surface-mounted Sales unit 1 metre ⚠ Check: values are indicative. Grouped cables, cables in thermal insulation or at higher temperatures have a lower rating. Protection follows IB ≤ In ≤ Iz; the final decision rests with the electrical design.Key functions
- Power transmission – three-phase 400 V with neutral up to ~27.7 kW with 40 A protection.
- Solid class 1 conductors – reliable contact in screw and push-in terminals.
- Colour-coded cores – L1, L2, L3, N, PE, faster and safer connection.
- PVC insulation and sheath – double protection for indoor installation.
- Sold by the metre – less waste and a more accurate estimate.
How does it differ from similar cables?
- NYM-J 5×6 mm² – smaller cross-section – about 34–41 A, for lighter loads or shorter runs.
- CYKY-L cable – black, also for outdoor and underground use with protection; NYM-J is for indoor use only.
Where is it used?
- Three-phase cookers and sockets.
- Supply to flat and house sub-boards – according to incoming protection.
- Workshops and garages – three-phase indoor circuits.
- Mixed loads – where single-phase appliances are also supplied.
Use by need
House builder.
Three-phase cooker, sub-board supply or three-phase socket with N and PE.Workshop or garage owner.
A three-phase circuit that can also supply single-phase appliances.Electrical contractor.
A universal three-phase cable for indoor wiring on projects.Practical example
For example, a three-phase circuit with 40 A protection has to be run to a cooker or workshop socket. NYM-J 5×10 mm² is suitable if the run is no longer than ≈ 75 m and the cable is not grouped or buried in thermal insulation.
Pros
- Solid copper conductors – hold their shape and terminate reliably.
- White sheath – neat appearance for surface installation.
- Made by Lietkabelis – established Lithuanian manufacturer with clear technical data.
- Sold by the metre – pay only for the length you need.
Cons / limitations
- Not for direct burial or unprotected outdoor use – choose CYKY-L for that.
- Not for portable equipment – solid conductors are not made for repeated flexing.
- PVC insulation – where halogen-free cables are required, choose NHXMH-J.
Safety and installation notes
- Before work, isolate the supply, secure it against switching on and verify that no voltage is present.
- Run cables in walls vertically and horizontally – so they aren't drilled later.
- Strip cores with a proper tool without nicking the copper.
- Before energising a new circuit, measuring insulation resistance is recommended.
- Installation must be carried out by a qualified electrician.
- 5×10 is not a single 50 mm² conductor.
- The cable is not chosen by the breaker alone – installation method and circuit length are checked too.
☝ Elsprendimai.eu recommends: NYM-J selection guide · CYKY-L cables for outdoors and undergroundQuick selection guide
Choose NYM-J 5×10 mm² for a three-phase 400 V indoor circuit with neutral.
5 × 10 mm²300/500 V40 AIndoorsSuitable when you need:- a three-phase 400 V circuit with N and PE;
- protection by a 40 A circuit breaker;
- a run of up to ≈ 75 m at 40 A load.
Check before ordering:- that the load and breaker match the 5×10 mm² cross-section;
- that the circuit is no longer than ≈ 75 m at 40 A load;
- that the cable will be installed indoors;
- that you order enough length for connection.
Important reminder: The 5×10 mm² designation alone does not define the maximum current or power. Choose the cable by load, installation method, circuit length and protective device.FAQ – frequently asked questions
What is the difference between NYM-J and KH05VV-U?
It is the same cable type: NYM-J is the common designation, KH05VV-U is the Lietkabelis product designation.Does 5×10 mean a total cross-section of 50 mm²?
No. These are 5 separate 10 mm² cores.Can it be laid outdoors or underground?
No. NYM-J is for indoor use; outdoors and underground choose CYKY-L, underground with mechanical protection and warning tape.Do you sell by the metre?
Yes, the sales unit is 1 metre; for project quantities we prepare a quotation.Which circuit breaker should I choose?
Usually 40 A; finally by load, installation method and circuit length (IB ≤ In ≤ Iz).Can it be installed under plaster?
Yes, NYM-J is intended for installation in walls, under plaster, in conduits and trunking indoors.Copper installation cable NYM-J | 5×10 mm² | 300/500 V | white | 1 m | Lietkabelis KH05VV-U 5G10
NYM-J 5×10 mm² (KH05VV-U 5G10) – white Lietkabelis copper cable with five solid conductors (L1, L2, L3, N, PE) for three-phase installation inside buildings. Sold by the metre.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerSingle-core wires are also called monolithic wires,
while multi-core wires are flexible wires.Wires usually have a single conductor covered with an insulating layer.
Cables have several insulated wires, covered with a common sheath.
Conductor properties of wires:
The resistance of copper conductors is lower (0.017Ω) than that of aluminum (0.028Ω),
but copper has better conductivity.
Copper has better electrical and thermal conductivity than aluminum.
Copper wires are more flexible, more resistant to corrosion, and more durable.
Aluminum wires quickly oxidize upon contact with air, forming a film that weakens the contact.
Copper wires carry higher currents than aluminum wires.
Copper conductors are denser than aluminum. Therefore, copper wire is heavier.The cross-sectional area of wires is chosen according to the power of specific equipment,
for example: for a 1kW load, a 1.57 mm² cross-sectional area of the conductor is required.
For aluminum wires: 5A per 1mm², and for copper wires: 8A per 1mm².The NYM-J/O installation cable is one of the widely used electrical cables for electrical installations in residential and commercial buildings. The name NYM refers to a specific type of construction that is designed for indoor electrical installations and, in some cases, outdoor applications.
Main features:
NYM-J – this is a cable with a grounding conductor (yellow-green), used in standard installations where grounding protection is necessary.
NYM-O – a cable without a grounding conductor, used where grounding is not required (e.g., in some lighting installations).
Advantages:Double insulation – NYM cables have PVC insulation with an additional outer layer, providing better protection against mechanical damage and moisture.
Fire resistance – these cables can be resistant to certain fire spread conditions, ensuring greater safety in emergency situations.
Flexibility – NYM cables are quite flexible, making them convenient for installation in both hidden and exposed installations.
Indoor and partial outdoor use – NYM cables are mostly used indoors, but in certain cases, they can also be used outdoors as long as they are not exposed to direct sunlight.
Disadvantages:UV sensitivity – NYM cables are not resistant to direct sunlight, so prolonged outdoor use may damage the insulation.
Not suitable for underground use – although NYM cables can be used outdoors, they are not suitable for direct burial in the ground without additional protection.
Limited thermal insulation – the cable is not suitable for installation in environments with extremely high temperatures.
Applications:Indoor electrical installations: commonly used in household electrical installations, such as in residential homes and offices.
Installation of light fixtures, outlets, and switches: NYM-J is particularly suitable for lighting and other electrical equipment installations where grounding is required.
Outdoor installations with protection: can be used outdoors but must be protected from UV radiation and mechanical damage.
Comparison with other cables:NYM vs CYKY: The CYKY cable is more suitable for outdoor installations as it has thicker insulation and better resistance to environmental impact. It can also be used underground. However, NYM cables are cheaper and more flexible, making them better suited for indoor installations.
NYM vs H07V-K: The H07V-K is a more flexible cable, typically used in industry or complex installations where high flexibility is needed. NYM is more convenient for household electrical installations.
Summary: The NYM-J/O cables are popular and widely used in electrical installations due to their versatility, ease of installation, and durability in indoor environments.The NYM-J/O type cable is round, solid, and designed for both industrial and household applications. It is intended for installation in dry and damp areas and can be laid under plaster or concrete. Due to its design and construction, the cable provides reliable protection against environmental factors in indoor conditions.
The cable is not UV-resistant, so when installing it outdoors, protection from direct sunlight is required. This can be achieved by using a black corrugated pipe that protects from UV exposure and mechanical damage. To make it easier to pull the cable through the pipe, it is recommended to use a special gel lubricant or cable-pulling tool.
Key Features:
Use: Industrial and household installations.
Installation: In dry and damp areas, under plaster and concrete.
UV protection: Requires additional protection when installed outdoors.
Suitable choice for ensuring a safe and reliable electrical installation indoors, such as by inserting it into a black corrugated pipe for easier cable routing, using gel lubricant or a cable-pulling tool.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products