CYKY-J 5G16 | 5×16 mm² | Copper power cable | 0.6/1 kV | black | 1 m | NKT
Code: C520218Price 15.00 € VAT incl.( 12.40 € VAT excl. )CYKY-J 5G16 (5×16 mm²) – 0.6/1 kV copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. NKT, price per 1 m.
-
CYKY-J 5G16 | 5×16 mm² | Copper power cable | 0.6/1 kV | black | 1 m | NKT
CYKY-J 5×16 mm² is a copper power cable made by NKT with 5 solid cores, PVC insulation and a black PVC sheath. It is designed for supplying and distributing electrical power in dry and damp rooms, outdoors and in the ground. Cores: L1, L2, L3, N, PE.
Key point:
This is a versatile cable for three-phase 400 V circuits with neutral: the same cable suits both a board feed indoors and a trench between buildings. The 16 mm² cross-section is intended for service feeds and board feeder lines. Price is per 1 m.Cores
5 × 16 mm² Cu – L1, L2, L3, N, PERated voltage
0.6/1 kV (U0/U)Outer diameter
21 mm – for choosing the cable glandCurrent rating (NKT)
87 A in air / 109 A in groundFire class (CPR)
Eca (EN 50575)Installation
indoors, outdoors, in groundConstruction and operating principle
Each core is a solid annealed copper wire (class 1 to LST EN 60228) with PVC insulation. The insulated cores are twisted together and covered with bedding and a PVC sheath, so the cable is round, robust and seals well in cable glands.
Core colours to LST HD 308: brown, black, grey, blue, green/yellow (PE). The green/yellow core is used only as the protective PE conductor.
Under normal conditions the conductor may reach +70 °C, and +160 °C during a short circuit. The permissible current depends on the installation method: in air, in conduit or in the ground the cable cools differently, so the same 16 mm² cross-section has a different current rating on different routes.
Why choose CYKY-J 5G16?
One cable type for the whole route – from the board indoors to a load outdoors or in another building, without joints when passing from inside into the ground. The 5×16 mm² configuration directly matches its purpose: three-phase 400 V circuits with neutral.Technical specifications
Product type Copper power cable with PVC insulation and PVC sheath Manufacturer NKT Model / designation CYKY-J 5G16 Number of cores and cross-section 5 × 16 mm² Core functions L1, L2, L3, N, PE Core colours (LST HD 308) brown, black, grey, blue, green/yellow (PE) Conductor Solid, annealed copper, class 1 (LST EN 60228) Conductor resistance at +20 °C, max. 1.15 Ω/km (LST EN 60228) Insulation PVC Filler Taped or extruded bedding Sheath PVC, black, UV-resistant Rated voltage U0/U 0.6/1 kV Test voltage 4 kV (AC) Outer diameter (approx.) 21 mm Weight (approx.) 1121 kg/km Minimum bending radius 250 mm (manufacturer data) Max. conductor temperature +70 °C; short circuit +160 °C Short-circuit current (1 s) 1.84 kA Installation temperature not below -5 °C Operating temperature -35 °C to +70 °C Current rating (single cable) 87 A in air (+30 °C); 109 A in ground (+20 °C, 0.7 m) – NKT data Flame propagation Test to LST EN 60332-1-2 Reaction to fire class (CPR) Eca Compliance 2011/65/EU (RoHS), 2014/35/EU (LVD), Regulation (EU) No 305/2011 Installation Dry and damp rooms, outdoors, in the ground Sales unit 1 m Diameter and weight are the manufacturer’s approximate values. The current rating is indicative: the final value is recalculated for the installation method, cable grouping and ambient temperature.
Main features
- Solid class 1 copper cores – hold firmly in terminals and are easy to shape in boards.
- UV-resistant PVC sheath – protect the cores and allow the cable to be laid in damp rooms, outdoors and in the ground.
- 0.6/1 kV rated voltage – a higher margin than 300/500 V installation cables.
- Colour coding to HD 308 – clear identification of L, N and PE, fewer wiring errors.
- Eca class under CPR – the cable has a declaration of performance required for construction products.
- Sold by the metre – you buy exactly the length the route needs.
Where is it used?
- Three-phase 400 V lines with N and PE
- Distribution boards, three-phase sockets, workshops
- Service feeds to a house or outbuildings from the metering cabinet
- Main and sub-board feeder lines, long runs
- Cable routes in the ground between buildings, in concrete, conduits and cable trunking
- Damp and wet rooms: basements, boiler rooms, garages, outbuildings
Use by need
For a designer.
A five-core TN-S solution: separate N and PE cores along the entire run.For an installing electrician.
One cable for three-phase sockets, boards and high-power loads – indoors, outdoors and in the ground.For a building contractor.
Service and board feeder lines on sites where the cable is laid in a trench or in concrete.Practical application
If an outbuilding distribution board located 50 m away needs a three-phase supply and the expected current is about 32 A, CYKY-J 5G16 can be laid in a trench directly in the ground. Approximate voltage drop: √3 × 32 A × 50 m × 1.15 Ω/km ≈ 3.2 V, i.e. about 0.8 % of 400 V (calculated with conductor resistance at +20 °C). The final cross-section and protective device are selected according to the design and installation conditions.Pros
- Suitable indoors, outdoors and in the ground – one cable for the whole route
- 0.6/1 kV rated voltage
- Solid copper cores – reliable contact in terminals
- Manufacturer declares UV resistance and Eca class
- UV-resistant – suitable for open outdoor runs
- Sold by the metre
Cons / limitations
- Solid cores are not suitable for moving equipment or frequent bending – use a flexible cable (e.g. H07RN-F) for that.
- PVC sheath: do not install below -5 °C.
- Eca class is not suitable where the design requires a higher CPR class or a halogen-free cable.
- Larger diameter (~21 mm) and weight (1121 kg/km) – glands and terminals must suit 16 mm² cores.
Safety and installation notes
- Before installation, isolate the circuit and verify that it is dead.
- Bending radius – at least 250 mm (manufacturer data).
- Do not install below -5 °C – cold PVC may crack.
- When laying in the ground, follow installation rules: proper depth, sand bedding, warning tape, mechanical protection under roads and driveways.
- Select the protective device according to the cable’s permissible current under the actual installation conditions.
- Use the green/yellow core only as PE – never as a phase or neutral.
- Work must be carried out by a qualified electrician; measure insulation resistance after installation.
Quick selection guide
5×16 mm²0.6/1 kVL1, L2, L3, N, PEØ ~21 mmEca (CPR)Suitable when you need:- Three-phase 400 V circuits with neutral
- Service feeds to a house or outbuildings from the metering cabinet
- To lay the cable in the ground or in a damp environment
Check before use:- Permissible current and protective device for the installation method
- Voltage drop on long runs
- Whether the design requires a higher CPR class
- Cable gland and seal size for the ~21 mm diameter
Important reminder: The cable does not replace calculation – cross-section, protection and installation method are confirmed by the electrical design or a qualified electrician.FAQ
What does the designation 5G16 mean?
5 cores of 16 mm², one of which is the green/yellow protective PE core (letter “G”).Can CYKY-J 5G16 be laid in the ground?
Yes, the manufacturer states that the cable may be laid in the ground; in a trench follow installation rules for depth, warning tape and mechanical protection.What current can a 5×16 mm² cable carry?
According to NKT – 87 A in air (+30 °C) and 109 A in ground (+20 °C, 0.7 m depth); in groups or at higher ambient temperature the value is reduced.How does CYKY-J differ from NYM-J?
NYM-J (300/500 V) is intended for installation inside buildings, while CYKY-J is a 0.6/1 kV cable that can be laid both outdoors and in the ground.What are the cable diameter and weight?
According to the manufacturer – about 21 mm and 1121 kg/km.At what temperature can it be installed?
Install at not below -5 °C; operate from -35 °C to +70 °C.CYKY-J 5G16 | 5×16 mm² | Copper power cable | 0.6/1 kV | black | 1 m | NKT
CYKY-J 5G16 is an NKT copper power cable, 5×16 mm², 0.6/1 kV, with solid cores and a black PVC sheath, intended for three-phase 400 V circuits with neutral. Suitable for laying indoors, outdoors and in the ground; Eca class, sold by the metre.
Published: 2026-11-13 · Data verified against the manufacturer’s datasheet: 2026-11-13
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerSingle-core wires are also called monolithic wires,
while multi-core wires are flexible wires.Wires usually have a single conductor covered with an insulating layer.
Cables have several insulated wires, covered with a common sheath.
Conductor properties of wires:
The resistance of copper conductors is lower (0.017Ω) than that of aluminum (0.028Ω),
but copper has better conductivity.
Copper has better electrical and thermal conductivity than aluminum.
Copper wires are more flexible, more resistant to corrosion, and more durable.
Aluminum wires quickly oxidize upon contact with air, forming a film that weakens the contact.
Copper wires carry higher currents than aluminum wires.
Copper conductors are denser than aluminum. Therefore, copper wire is heavier.The cross-sectional area of wires is chosen according to the power of specific equipment,
for example: for a 1kW load, a 1.57 mm² cross-sectional area of the conductor is required.
For aluminum wires: 5A per 1mm², and for copper wires: 8A per 1mm².The electrical supply cable is the main cable through which electricity is supplied from the ESO (Electricity Distribution Operator) meter cabinet to the internal electrical system of the consumer's building. This cable is a crucial link between the electrical network and the building's installation.
Key Features:
Connection to the ESO network – The supply cable connects the building's electrical system to the ESO distribution network. It is the first element of the electrical installation through which electricity enters the building.
Current capacity – The supply cable must be suited to transmit the required current strength according to the consumer's electrical needs (e.g., 25A, 32A, or more).
Environmental resistance – The cable is often installed outdoors or underground, so it must be resistant to mechanical impacts, UV rays, and moisture.
Number of conductors and cross-section – The most commonly used supply cables are 4 or 5 conductors (depending on grounding requirements), with conductors of 16 mm², 25 mm², or more, depending on the expected load.
Example: CYKY 4x16 or CYKY 5x16 – these are popular supply cables used for 3-phase power supply at 230/400V. They have four or five copper conductors designed for higher currents.
The supply cable is a vital link in the electricity supply, so it is important to ensure that it is correctly selected according to the consumer's electrical load and the environmental conditions in which it will be installed.We recommend choosing the CYKY supply cable. For single-phase supply, we recommend a 3-conductor cable (CYKY 3×4 mm², 3×6 mm²), and for three-phase supply, a 5-conductor cable (CYKY 5×4 mm², 5×6 mm²).
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Equipotential bonding bar | terminal | 4x7 | 4P | 100A | DIN | brass | Legrand | 04884Code: 04884 LegrandPotential equalization busbar designed to ensure reliable grounding and equipotential bonding. This solution is essential in both residential and industrial facilities where electrical safety, protection against overvoltage, and the effects of lightning discharges are important. Thanks to its robust construction, brass contacts, and safe insulating housing, the busbar ensures long-term, stable, and safe operation even under demanding operating conditions.
Price 33.38 € VAT incl.( 27.59 € VAT excl. )Cable sheath and wire stripper 0.2–4.0 mm² | ErgoStrip KNIPEXCode: 169501SBKNIPEX high-quality, ergonomically designed wire and cable stripping tool for fast, precise, and safe work. This stripping knife is highly favored by professional electricians for its versatility, durability, and practical design. Suitable for removing insulation from both signal and power wires, as well as for installation, data, and coaxial cables.
Perfectly suited for use on construction sites and in domestic installations, especially where wires need to be quickly and accurately prepared for connection in confined spaces.
Price 48.40 € VAT incl.( 40.00 € VAT excl. )Industrial modular socket panel | 2×CEE 32 A 5P 400 V + 4×Schuko 230 V | space for 11 modules of protection | IP54 | SEZ ROS11/x-22Code: 88754SEZ ROS11/x-22 – a sealed industrial panel with sockets (2×CEE 32 A 5P 400 V + 4×Schuko 230 V) and space for 11 modules of protective devices. Degree of protection: IP54, mounting – wall-mounted (surface).
Price 62.00 € VAT incl.( 51.24 € VAT excl. )Galvanized grounding rod | Ø20 mm | 1500 mm | 5000750 219/20Code: 5000750Galvanized grounding rod designed for reliable grounding of electrical systems. It is one of the most important components in both residential and industrial installations, ensuring the safe dissipation of excess electrical energy into the ground. This rod features excellent corrosion resistance, durability, and easy installation. Due to its special construction, the electrodes can be connected to each other without additional couplings, allowing for quick and reliable installation of a grounding system even in more complex conditions.
Price 16.82 € VAT incl.( 13.90 € VAT excl. )Holder | fastening strap | 22 mm | black | UP-22 | 5901350805718Code: UP-22Holder – a fastening tie designed for securing and organizing cables, wires, and various components. This compact yet strong tie ensures reliable fixation, aesthetics, and safety in electrical installations as well as in household or industrial systems. Due to its simple installation and universal size, this holder is indispensable for both professionals and everyday users.
Price 0.09 € VAT incl.( 0.07 € VAT excl. )Terminal | connector paste for contacts | reduces oxidation | 35.3g | WAGO | ALU PLUS | 249-130 | for connecting aluminium and copper wiresCode: 4017332133890Contact paste designed to protect aluminum conductors from oxidation and ensure a reliable electrical connection. This special paste allows aluminum and copper conductors to be safely and efficiently connected within the same connector, making it particularly useful when renovating older electrical installations where aluminum wiring is commonly found.
Aluminum naturally oxidizes, and the resulting oxide layer increases contact resistance, causes connection heating, and may become a source of electrical faults. By using WAGO ALU-PLUS, the oxidation layer is reduced, electrical conductivity is improved, and the service life of the connection is significantly extended.
Price 2.83 € VAT incl.( 2.34 € VAT excl. )