Products catalog

  • Three-phase voltage and current relay | 3F+N | 63 A | phase sequence | DIN | EL-AVR-XXTF

    Code: EL-AVR-XXTF

    The EL-AVR-XXTF is a three-phase digital voltage relay that monitors the voltage of each phase and disconnects the load directly through its contacts.

  • Three-phase voltage and current relay | 3F+N | 63 A | phase sequence | DIN | EL-AVR-XXTF

    The EL-AVR-XXTF is a three-phase digital voltage relay that monitors the voltage of each phase and disconnects the load directly through its contacts. In addition to voltage, it measures the load current and disconnects the circuit when the set limit is exceeded.

    Key point:
    One relay protects the whole three-phase supply or three-phase equipment: each phase is monitored separately and the load is disconnected automatically in case of a network fault.
    Load current
    63 A
    Network / supply
    3F+N, 3×380 V AC
    Functions
    phase sequence, current limit

    How it works

    The relay is connected to the three-phase supply (with neutral, depending on the model); the voltage of each phase is measured separately.

    When the voltage in any phase leaves the limits, the load is disconnected; depending on the model, asymmetry, phase sequence or phase loss are also monitored. When the set current limit is exceeded, the load is also disconnected – this limits the power drawn.

    When the parameters return to normal, the load is reconnected after the set delay.

    Why choose the EL-AVR-XXTF?
    One device instead of several single-phase relays – less space in the board and a clear view of each phase.

    Technical specifications

    Product type Three-phase digital voltage and current relay (power type)
    Manufacturer / code EL-AVR-XXTF
    Network 3F+N, 3×380 V AC
    Rated current 63 A
    Own consumption < 6 W
    Display / indication LED 3 × 6 digits
    Measuring accuracy ±1 %
    Operating temperature −20…+55 °C
    Mounting DIN 35 mm

    Main functions

    • Monitoring of each phase – a fault is detected in any phase.
    • Over- and undervoltage protection – appliances are disconnected when the neutral breaks or the network fails.
    • Current limit – an overloaded circuit is disconnected, the power drawn is limited.
    • Phase sequence monitoring – the motor is not started with swapped phases.
    • Neutral loss monitoring – reacts to a broken neutral conductor.
    • Digital display or indication – the status is visible at once.

    Where is it used?

    • Three-phase supplies of houses and country homes
    • Workshops, garages, farm buildings
    • Three-phase pumps, compressors, machine tools
    • Heat pumps with three-phase supply
    • Small production and storage premises

    Use by need

    For the owner of a three-phase house.
    One relay monitors all phases.
    For a workshop or farm owner.
    Three-phase equipment is disconnected on network faults.
    For the electrician.
    One device instead of several – fewer connections in the board.

    Practical use

    A workshop has a three-phase supply: machine tools and compressor are three-phase, lighting and sockets single-phase. If one phase fails, the EL-AVR-XXTF disconnects the load and reconnects it automatically when the parameters return.

    Pros

    • Monitors each phase
    • Automatic reconnection
    • One device instead of several
    • DIN mounting

    Cons / limitations

    • Does not protect against lightning and short surges – an SPD is needed
    • Does not replace circuit breakers and RCDs
    • IP20 – dry board only
    • The manufacturer does not publish a full datasheet – parameters per supplier specification

    Safety and installation notes

    • Install only after disconnecting the supply; work must be done by a qualified electrician.
    • Upstream – a circuit breaker with a current not higher than the relay's rated current.
    • Check phase and neutral wiring against the diagram.
    • Install the surge protective device (SPD) before the relay.

    Quick selection guide

    3F+N
    63 A
    phase sequence
    Suitable when you need:
    • to protect a three-phase supply
    • to protect three-phase equipment
    • to monitor each phase
    Check before use:
    • main circuit breaker current ≤ 63 A
    • whether an N conductor is present if the model needs it
    Important reminder: the relay does not replace a surge protective device, circuit breakers or RCDs.

    FAQ

    Is a neutral conductor needed?
    For most three-phase voltage relays – yes, because the phase voltage is measured.
    Does it protect against lightning?
    No – an SPD is needed for that.
    What current should I choose?
    Not lower than the main circuit breaker current – the EL-AVR-XXTF suits up to 63 A.
    Does it disconnect all phases together?
    Depends on the model and mode – in SYN mode all phases are disconnected together.
    Are settings retained?
    Yes, the settings are kept during a power cut.
    Does it replace an RCD?
    No.

    Three-phase voltage and current relay | 3F+N | 63 A | phase sequence | DIN | EL-AVR-XXTF

    EL-AVR-XXTF – protection of a three-phase supply and three-phase equipment against voltage and phase faults.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy