Electromagnetic Door Lock | Bolt Lock | 12VDC | NC | Holding Force 800kg | 0/3/6s Time Delay | Fail-Secure
Code: ES-OC-150S-NCThe surface-mounted electric bolt lock is designed for access control systems requiring reliable door locking. The lock operates on an NC (fail-secure) principle: when 12 V DC power is supplied, the door is locked, and when the power supply is lost or disconnected, the door is unlocked. The aluminium alloy housing, stainless steel bolt, adjustable 0 / 3 / 6 s locking delay, and 4-wire interface ensure reliable operation in offices, apartment buildings, warehouses, server rooms, and other access control systems.
-
Surface-mounted electric bolt door lock – 12 V DC, NC, 0/3/6 s delay, 4-wire interface
Surface-mounted electric bolt door lock is intended for locking doors in access control systems. This specific lock version operates according to the NC principle: when power is disconnected, the lock bolt remains extended and the door is locked, while applying 12 V DC power retracts the bolt and unlocks the door.
The lock can be controlled by a keypad, card reader, biometric terminal, intercom, access control controller or another device providing a suitable signal. The lock has a 4-wire, 12–24 V interface. The exact purpose of each wire and the connection diagram must be checked against the diagram supplied with the product.
The surface-mounted construction is installed on the door frame or another suitable horizontal surface. The aluminium-alloy housing, stainless-steel bolt and adjustable 0, 3 or 6-second delay are suitable for more intensively used wooden, metal and PVC-profile doors.
Operating mode – NC:
When power is disconnected, the lock remains locked. When 12 V DC power is applied, the bolt retracts and the door is unlocked.Important information regarding emergency exit doors:
The NC, fail-secure operating principle means that the door remains locked if the power supply is interrupted. Nevertheless, the suitability of the lock for emergency exits, fire doors or other special-purpose exits must be assessed according to the complete door system, the project and the applicable safety requirements.Package contents note:
The power supply, keypad, access control controller, card reader, exit button and other system components that may be shown in diagrams are not included. They must be selected and purchased separately.Lock type
Electric bolt lockOperating principle
NCPower supply
12 V DCOperating current
1200 mABolt diameter
Ø12.5 mmBolt travel
15 mmLocking delay
0 / 3 / 6 sNC, fail-secure operating principle
This lock is an NC type. When 12 V DC is supplied to the lock, the electric bolt actuator extends or keeps the bolt extended, so the door remains locked.
When the access control system provides a 12 V DC unlocking signal, the electric actuator retracts the bolt and releases the door.
Operating sequence:- Power supplied – the lock is locked.
- Power disconnected – the lock is unlocked.
- Power supply fails – the door is released.
Electric bolt locking
The lock secures the door with a metal bolt that enters a prepared opening in the strike plate. The bolt mechanically connects the door leaf to the frame and prevents the door from opening.
The bolt diameter is 12.5 mm, and its travel is 15 mm. For reliable operation, the bolt and the receiving opening must be precisely aligned on the same axis.
The door must close without a heavy impact, and the door closer, hinges and frame geometry must ensure that the bolt opening stops in the same position every time.
Bolt alignment:
If the bolt presses against the edge of the receiving opening, the lock may fail to lock, jam, overheat or wear more quickly. The lock must not be used to pull in or mechanically straighten the door leaf.Surface mounting
The lock housing is secured to the door frame or another suitable surface, so it does not need to be fully recessed into the frame. This can reduce the need for complex routing and simplify installation on existing door structures.
Surface mounting can be used on wooden, metal and PVC-profile doors provided that the door and frame construction is sufficiently strong and the lock and strike can be securely mounted at the installation point.
Installation orientation:
The lock must be installed in a horizontal plane. An incorrect position may interfere with bolt movement and cause unreliable locking.Possible installation methods
At the top of the frame
The lock housing is mounted on the upper horizontal part of the frame, while the strike plate is mounted on the door leaf. This is the most commonly used installation method.
On the side of the frame
The lock may be installed on the side of the door frame, provided that the permitted horizontal operating position is maintained and the bolt is precisely aligned with the receiving opening.
On double doors
The lock can be used to secure one leaf of a double door, provided that the second leaf is reliably fixed and the construction allows the strike to be mounted rigidly.
Door compatibility:
Before installation, assess the door opening direction, frame profile, door-leaf clearance, hinge play, operation of the door closer, cable routing and the available options for mounting the strike.Adjustable 0, 3 or 6-second delay
The locking delay can be set to 0, 3 or 6 seconds. The setting is selected using a DIP switch inside the housing.
The delay allows the door to close completely before the bolt extends. This is particularly important for doors with a mechanical closer, because a bolt that extends too early may strike a door leaf that has not yet closed.
Recommended setting:- 0 seconds – for doors that close quickly and accurately.
- 3 seconds – for most conventional doors with a closer.
- 6 seconds – for slower-closing or heavier doors.
The delay is not a door sensor:
The time delay only postpones bolt extension. It does not confirm that the door has actually closed completely. Where reliable status monitoring is required, the feedback signal or a separate door-position sensor must be used correctly.4-wire, 12–24 V interface
The lock has a 4-wire interface with a specified voltage of 12–24 V. This parameter applies to the interface, while the operating voltage of the lock itself is 12 V DC.
Before connecting the lock to an access control controller, verify the purpose of each wire, the polarity and the interface connection diagram.
Before connection:
Check the purpose of the wire colours, polarity and the product's 4-wire interface diagram.Power supply selection
The lock requires a stabilised 12 V DC power supply. The specified operating current is 1200 mA, so the power supply must provide at least this current and include additional capacity.
If the same power supply also powers the access controller, card reader, keypad, relay or other components, the current consumption of all devices must be added together.
A longer cable or an insufficient cable cross-section may cause voltage drop. As a result, the lock may not fully extend the bolt, may operate unstably or may fail to lock.
Power supply safety:
The lock must not be connected directly to a 230 V AC mains supply. Use only a suitable 12 V DC power supply and observe the specified polarity.Low heat generation
The electric bolt actuator uses a copper coil designed for a lower temperature rise during long-term operation. This is relevant for an NC lock that is continuously powered while locked.
Correct supply voltage, sufficient cable cross-section and free bolt movement help reduce the thermal load on the coil and extend the service life of the lock.
Abnormal heating:
If the lock housing becomes very hot, vibrates continuously or produces a loud buzzing sound, disconnect the power and check the voltage, polarity, bolt movement and installation accuracy.Durable metal construction
The lock housing is made of aluminium alloy, while the moving bolt is made of stainless steel. This construction is designed for intensive use and increased mechanical resistance.
Technical specifications
Product type Surface-mounted electric bolt door lock Operating type NC, fail-secure Locking principle The lock unlocks when power is applied Unlocking principle When power is disconnected or lost, the lock remains locked Installation method Surface-mounted, in a horizontal plane Operating voltage 12 V DC Operating current 1200 mA Interface type 4 wires Interface voltage 12–24 V Locking delay 0 / 3 / 6 seconds Delay adjustment Using a DIP switch Bolt diameter Ø12.5 mm Bolt travel 15 mm Housing material Aluminium alloy Bolt material Stainless steel Weight 0.509 kg Suitable door constructions Wooden, metal and PVC-profile doors, subject to assessment of structural compatibility Main features and benefits
- NC operation – the door remains locked if power is lost.
- 12 V DC power supply – for access control systems.
- Surface mounting – reduces the need for frame routing.
- Electric bolt locking.
- 0, 3 or 6-second delay.
- Four-wire system – for power and status signalling.
- Ø12.5 mm bolt – made of stainless steel.
- 15 mm bolt travel.
- Aluminium-alloy housing.
- Low heat generation – for continuous powering.
- Suitable for intensively used access-control doors.
Where can it be used?
- In office buildings – for office doors and restricted-access areas.
- In hotels – for service and technical rooms.
- In apartment buildings – for controlling common-area doors.
- In shops – for storage areas and staff-only zones.
- In educational institutions – for restricted-access rooms.
- In warehouses – for internal security zones.
- In server rooms – for technical equipment rooms.
- In administrative buildings.
- In healthcare facilities – for restricted-access areas.
- In other access control systemswhere NC locking is required.
Installation procedure
- Assess the door construction. Check the frame, door leaf, opening direction and door closer.
- Select a horizontal installation position. The lock must be mounted securely and in the correct orientation.
- Mark the fixing points. Use the housing or an installation template.
- Secure the lock housing. Use fasteners suitable for the door material and load.
- Install the strike. Its opening must align precisely with the bolt axis.
- Check the bolt travel. The bolt must move freely and must not rub against the edges of the opening.
- Route the power and signal wires. Protect them against pinching and mechanical damage.
- Connect the 12 V DC power supply. Check the polarity and the current capacity of the power supply.
- Connect the 4-wire interface. Follow the diagrams for the lock and access controller.
- Set the delay to 0, 3 or 6 seconds.
- Check NC operation. When power is disconnected, the lock must remain locked.
- Perform several test cycles. Check locking, unlocking, door closing and the function of all wires.
Usage and safety notes
- Use only a 12 V DC power supply.
- Do not apply 230 V AC directly to the lock.
- Observe the power-supply polarity and the supplied wiring diagram.
- Take into account that the lock will remain locked if power is lost.
- Install the lock in a horizontal plane.
- Do not allow the bolt to jam mechanically.
- The door closer must close the door accurately and without a heavy impact.
- Do not use outdoorsunless a suitable IP protection rating has been confirmed.
- Protect the lock from water, condensation and conductive dust.
- Periodically check the mounting screws and bolt alignment.
- Installation and connection must be performed by a qualified specialist.
Maintenance
- Regularly check the alignment of the bolt and receiving opening.
- Remove dust and dirt from the bolt movement area.
- Check the mounting screws and tighten them if necessary.
- Monitor the condition of cables and connections.
- Check the door closer adjustment.
- Periodically check NC operation by disconnecting the power.
- Do not pour oil into the lockunless this is specified in the instructions.
- If jamming, unusual noise or overheating occurs, disconnect the power and contact a specialist.
FAQ – frequently asked questions
Is this an NC or NO lock?
This specific lock is an NC, fail-secure type.How does an NC lock work?
When 12 V DC power is applied, it locks; when the power is lost or switched off, it unlocks.What happens if the power fails?
The bolt remains extended and the door remains locked.Is the lock installed inside the door frame?
No. It is a surface-mounted lock secured to the frame or another suitable surface.Is routing required?
Deep routing for the lock housing is not required, although a cable route, fixing holes and the receiving opening for the bolt may need to be prepared.What power rating is required for the power supply?
The specified lock current is 1200 mA, so the power supply must provide at least 1.2 A and have additional reserve capacity.Does the lock have a locking delay?
Yes. A delay of 0, 3 or 6 seconds can be selected.What is the delay used for?
It allows the door to close completely before the locking bolt extends.Does the lock provide a status feedback signal?
Yes. The supplied information specifies a four-wire system with feedback.Is the lock suitable for wooden, metal and PVC doors?
Yes, provided that the door and frame construction allow it to be installed securely and accurately.Are the power supply and controller included?
No. The power supply, access controller, exit button, keypad and reader are not included.NC, fail-secure surface-mounted electric bolt lock
The electric bolt lock is intended for controlling wooden, metal and PVC-profile doors in access control systems. It can be connected to a keypad, card reader, intercom, controller or another control device.
This specific version operates according to the NC principle: when 12 V DC power is supplied, the door locks, and when power is lost or switched off, it unlocks.
Surface mounting reduces the need for complex frame routing, while the adjustable 0, 3 or 6-second delay allows the bolt operation to be matched to the speed of the door closer.
The aluminium-alloy housing, Ø12.5 mm stainless-steel bolt and 15 mm travel are designed for more intensive use. A 4-wire, 12–24 V interface is provided and must be connected according to the specific wiring diagram.
The lock requires a stabilised 12 V DC power supply capable of delivering at least 1.2 A. Before installation, check the wiring diagram, the 4-wire interface diagram, compatibility with the door construction, and precisely align the bolt with the receiving opening.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Marker cable ties | 2.5x110 mm | white | nylon PA66 | 100 pcs | 4772124000407Code: 4772124000407Price 2.42 € VAT incl.( 2.00 € VAT excl. )













