Products catalog

  • Electromagnetic door lock | electric strike | 12VDC | 75x20.5x28mm | ASSA ABLOY | EFF EFF E7

    Code: EFF EFF E7

    ASSA ABLOY EFF EFF E7 – a compact electromagnetic door strike designed for electrically controlled door locking systems. It operates with a 12V DC power supply, has a universal DIN direction, no mechanical release and no memory function. Due to its small dimensions, the strike is suitable for various interior doors, access control systems, intercom systems and electric lock systems. 

  • ASSA ABLOY EFF EFF E7 electromagnetic door strike – 12V DC, universal DIN direction, without memory, without mechanical release

    ASSA ABLOY EFF EFF E7 – a compact electromagnetic door strike designed for electrically controlled door locking systems. It operates with a 12V DC power supply, has a universal DIN direction, no mechanical release and no memory function. Due to its small dimensions, the strike is suitable for various interior doors, access control systems, intercom systems and electric lock systems.

    Main idea:
    This electromagnetic strike is designed for locking and unlocking doors using an electrical control signal. It can be used together with intercoms, access control systems, code keypads, exit buttons or other compatible door control solutions.
    Power supply
    12V DC
    DIN direction
    Universal
    Memory function
    None
    Dimensions
    75 x 20.5 x 28 mm

    Operating principle

    The electromagnetic door strike is installed in the door frame and works together with a mechanical door lock or latch. When it receives a 12V DC control signal from a compatible system, the strike allows the door to be unlocked without using a mechanical key from the outside.

    Since this model is without a memory function, the operation of the strike depends on the control signal. It does not have a mechanical release, so emergency exit, door opening and safety solutions must be provided within the overall door control system.

    Why is the universal DIN direction useful?
    The universal DIN direction makes it easier to adapt the strike to different door opening directions. This is convenient when installing it on both left-hand and right-hand doors, but before installation it is still necessary to check the compatibility of the specific door, lock latch and frame.

    Technical parameters

    Manufacturer ASSA ABLOY
    Model EFF EFF E7
    Product type Electromagnetic door strike / electric door lock
    Supply voltage 12V DC
    DIN direction Universal
    Memory function None
    Mechanical release None
    Dimensions 75 x 20.5 x 28 mm
    Operating temperature From -15°C to +40°C
    Application Electric door locking and access control systems

    Main functions

    • Electric door unlocking – can be controlled by a 12V DC signal from a compatible system.
    • Universal DIN direction – easier adaptation to different door opening directions.
    • Compact dimensions – 75 x 20.5 x 28 mm.
    • Without memory function – the strike operation depends on the control signal.
    • Without mechanical release – designed for systems where unlocking is provided electrically.
    • Suitable for access control – can be integrated with intercoms, code keypads, exit buttons or controllers.

    Where is it used?

    • In offices – for employee, technical and restricted-access room doors.
    • In apartment buildings – for common areas, staircases or auxiliary door systems.
    • In administrative buildings – for controlled access to offices, storage rooms and technical zones.
    • In commercial premises – for doors in shops, warehouses and service areas.
    • In private properties – for gates, auxiliary rooms, storage rooms or other electrically controlled doors.
    • In intercom systems – for door unlocking via a call panel or indoor monitor.

    Practical installation example

    For example, the electromagnetic strike is installed in an office door frame and connected to a 12V DC access control power supply. Door unlocking can be controlled via an RFID card reader, code keypad, intercom or exit button.

    It is important that the strike and the door lock latch are precisely aligned. Incorrect installation can lead to harder door closing, latch jamming or unreliable unlocking.

    Use according to needs

    For electricians: a compact 12V DC solution suitable for installation in a door frame and connection to an access control or intercom system.

    For security system installers: can be used together with access control controllers, RFID readers, code keypads, intercoms and exit buttons.

    For facility administrators: suitable when access to employee, technical or shared-use rooms needs to be restricted and doors need to be unlocked electrically.

    For designers: the universal DIN direction and compact dimensions make it easier to plan strike installation in various interior door systems.

    Advantages

    • 12V DC power supply – suitable for many intercom and access control systems.
    • Universal DIN direction – more convenient adaptation to doors of different directions.
    • Compact dimensions – 75 x 20.5 x 28 mm.
    • Electric unlocking – convenient to use with access control controllers.
    • Suitable for interior doors – offices, commercial premises and administrative buildings.
    • ASSA ABLOY EFF EFF – a solution from a professional door locking systems manufacturer.

    Disadvantages / limitations

    • Works only with 12V DC power supply – a suitable power supply and control system are required.
    • No memory function – after the control signal, the strike operation depends on the specific system solution.
    • No mechanical release – emergency exit and door opening solutions must be provided within the system.
    • Compatibility must be checked – with the door lock, latch, frame and selected access control system.
    • Operating temperature up to +40°C – not suitable for locations where the temperature may exceed the specified operating limits.

    Safety and installation notes

    The electromagnetic strike must be installed according to the technical requirements of the door, lock and access control system. Before installation, it is necessary to evaluate how safe exit from the room will be ensured and how the strike will operate in the event of a power failure.

    • Installation and electrical connection must be carried out by a qualified specialist.
    • Before installation, the electrical power supply must be disconnected.
    • Use only 12V DC power supply that meets the requirements of the specific access control system.
    • Check the alignment of the strike and the door lock latch before finally fixing the device.
    • Evaluate emergency exit requirements, especially in public, commercial or employee-used premises.
    • Observe the operating temperature range from -15°C to +40°C.
    • Before operation, check the door unlocking and locking function through several cycles.

    Quick selection guide

    Choose ASSA ABLOY EFF EFF E7 when a compact electromagnetic door strike operating on 12V DC is required for electric access control. The model is suitable for systems where mechanical release and memory function are not required.

    Power supply
    12V DC
    Direction
    Universal DIN
    Memory
    None
    Release
    No mechanical release
    Suitable when you need:
    • electrically unlocked doors;
    • a 12V DC electromagnetic strike;
    • a compact solution for a door frame;
    • integration with an intercom or access control system;
    • a strike adaptable to universal DIN direction.
    Check before installation:
    • whether the system uses 12V DC power supply;
    • whether the strike is compatible with the existing lock and door latch;
    • whether there is enough space in the door frame for the 75 x 20.5 x 28 mm housing;
    • whether mechanical release is required;
    • whether safe emergency exit from the room is provided.
    Important reminder:
    This model is without memory and without mechanical release. Before ordering, it is necessary to evaluate whether this operating logic is suitable for the specific door, access control system and site safety requirements.

    FAQ – frequently asked questions

    What is the EFF EFF E7 electromagnetic strike used for?
    It is designed to electrically control door unlocking in access control, intercom, code keypad or other compatible systems.
    What supply voltage is required?
    This model requires a 12V DC power supply.
    Does the strike have a mechanical release?
    No, this model does not have a mechanical release. Door opening and emergency exit solutions must be provided within the overall system.
    What does it mean that the strike is without memory?
    It means that the strike does not have an additional mechanical or electrical memory function. Its operation depends on the control signal and the chosen system connection.
    Is it suitable for left-hand and right-hand doors?
    Yes, a universal DIN direction is specified, so the strike can be adapted to different door opening directions. Before installation, the compatibility of the specific door construction must be checked.
    At what temperature can the strike be used?
    The operating temperature is from -15°C to +40°C.

    Compact 12V DC electromagnetic door strike for access control systems

    ASSA ABLOY EFF EFF E7 is a practical solution for doors that need to be unlocked electrically via an intercom, access control controller, code keypad or another compatible system.

    Thanks to 12V DC power supply, universal DIN direction, compact dimensions and the professional ASSA ABLOY EFF EFF solution, this electromagnetic strike is suitable for various interior door control systems. Before ordering, it is necessary to consider that the model has neither a memory function nor mechanical release.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy