Products catalog

  • Extended insulated wire ferrule | bootlace ferrule | 2.5 mm² | 18 mm | crimp type | blue | DIN 46228-4 | 100 pcs | 260140

    Code: 260140

    Extended insulated ferrule 2.5 mm² (code 260140) – a crimp-type tinned copper ferrule with a blue plastic sleeve, designed to terminate stranded conductor ends before connecting them into screw, spring-cage or breaker terminals. The extended 18 mm contact tube is designed for deep terminals – circuit breakers, switch-disconnectors, variable frequency drives and contactors – where a standard 8 mm ferrule does not reach the contact. Pack of 100 pcs.

  • Extended insulated wire ferrule | 2.5 mm² | 18 mm | grey | crimp type | 100 pcs. | APF-2,50/18 | 260140

    Extended insulated wire ferrule designed for preparing the end of a 2.5 mm² stranded conductor before connection to a suitable terminal. The APF-2,50/18 has an 18 mm metal contact sleeve and an overall length of 25.0 mm. The insulation collar is grey. Pack quantity – 100 pcs.

    Key point

    The ferrule is used to form the strands of a flexible conductor into one compact crimped termination before insertion into a suitable terminal. This helps prevent individual strands from spreading, simplifies insertion and provides a neat, repeatable termination.

    Conductor cross-section
    2.5 mm²
    Metal sleeve length
    18 mm
    Overall length
    25.0 mm
    Pack
    100 pcs.

    Operating principle

    The end of a stranded conductor consists of multiple fine wire strands. If inserted directly into a screw or other suitable terminal, individual strands may spread, move or be clamped unevenly.

    The ferrule is fitted over the stripped conductor and crimped using a suitable crimping tool. During crimping, the metal sleeve compresses the strands into one compact termination that is easier to insert into a terminal.

    Why use APF-2,50/18?

    The extended 18 mm metal sleeve is useful when the terminal design requires a longer formed contact section than a shorter standard ferrule can provide.

    Technical specifications

    Product type Extended insulated wire ferrule
    Manufacturer Sofamel
    Model APF-2,50/18
    Manufacturer code 260140
    Conductor cross-section 2.5 mm²
    Metal contact sleeve length 18 mm
    Overall ferrule length 25.0 mm
    Metal sleeve internal diameter 2.2 mm
    Metal sleeve wall thickness 0.15 mm
    Insulation collar diameter 4.0 mm
    Insulation wall thickness 0.25 mm
    Colour Grey
    Installation method Crimped
    Pack quantity 100 pcs.
    Important: 18 mm dimension

    18 mm is the length of the metal contact sleeve, not the total ferrule length. The overall length of APF-2,50/18 is 25.0 mm. This distinction is important when checking compatibility with a specific terminal depth.

    Why are wire ferrules used?

    Wire ferrules are used to form the end of a stranded conductor before insertion into a terminal. A correctly crimped ferrule keeps the individual strands together and reduces the risk of strands remaining outside the clamping area.

    Ferrules also simplify repeatable wiring work in electrical panels, control cabinets and other installations where many similar conductor terminations are required.

    Main functions

    • Designed for terminating a 2.5 mm² stranded conductor.
    • Keeps individual strands together in one contact termination.
    • Extended 18 mm metal contact sleeve.
    • 25.0 mm overall ferrule length.
    • Grey insulated entry collar.
    • Installed by crimping.
    • Suitable for professional wiring in panels, automation systems and other electrical equipment.

    Where is it used?

    • Electrical panel assembly.
    • Automation and control cabinets.
    • Connecting stranded conductors to suitable terminals.
    • Preparation of control-circuit wiring.
    • Industrial automation equipment.
    • Electrical installation repair and modernisation.
    • Applications requiring an extended 18 mm contact section.

    Use by requirement

    For electricians
    Suitable for preparing the ends of 2.5 mm² stranded conductors before connection to suitable equipment terminals.
    For panel builders
    The extended 18 mm sleeve is useful where the terminal construction requires a longer formed contact section.
    For automation installers
    Helps standardise conductor-end preparation where many identical 2.5 mm² terminations are made in one panel.

    Correct installation principle

    1. Select the ferrule according to conductor cross-section – this model is for 2.5 mm² stranded conductors.
    2. Strip the conductor so that all strands can be fully inserted into the metal sleeve.
    3. Insert the conductor fully and make sure no strands remain outside the metal sleeve.
    4. Crimp using a suitable ferrule crimping tool designed for the relevant conductor size.
    5. After crimping, check the mechanical retention before inserting the conductor into the terminal.
    Important when crimping

    The quality of the termination depends not only on the ferrule but also on correct conductor preparation and the use of a suitable crimping tool. After crimping, the metal sleeve should be evenly deformed without visible cracking or damage.

    When should an extended 18 mm ferrule be selected?

    An extended ferrule is selected when the terminal construction or installation requires a longer formed contact section than provided by a shorter standard ferrule. The 18 mm metal section creates a longer crimped conductor end.

    A longer ferrule is not automatically suitable for every terminal. The terminal insertion depth, conductor cross-section and equipment manufacturer's connection requirements must be checked.

    Advantages

    • Designed specifically for 2.5 mm² stranded conductors.
    • Extended 18 mm metal contact section.
    • Clearly specified overall length of 25.0 mm.
    • Insulated collar helps guide the conductor into the sleeve.
    • Suitable for professional panel and automation wiring.
    • 100-piece pack is convenient for repetitive installation work.

    Limitations

    • Designed for 2.5 mm² stranded conductors and should not automatically be used for other cross-sections.
    • 18 mm refers to the metal sleeve, not the overall ferrule length.
    • A suitable crimping tool must be used.
    • Terminal compatibility must be checked against the specific equipment requirements.
    • Rated voltage or current should not be assigned solely from ferrule size.
    • Do not rely on insulation colour alone to identify conductor cross-section – check the technical data.
    • DIN or other standard compliance should not be stated unless confirmed by manufacturer documentation.

    Safety and installation notes

    • De-energise the electrical circuit before work.
    • Use a ferrule matching the conductor cross-section.
    • Do not damage conductor strands while stripping insulation.
    • All conductor strands must enter the metal sleeve.
    • Use only a suitable and serviceable crimping tool.
    • After crimping, check that the ferrule is mechanically secure on the conductor.
    • Before insertion, verify that the 18 mm contact section is suitable for the terminal construction.
    • Electrical installation work should be carried out by qualified personnel.

    Quick selection guide

    2.5 mm² | 18 mm metal sleeve | 25.0 mm overall length | grey | crimp type | 100 pcs.
    Suitable when you need: professional termination of a 2.5 mm² stranded conductor with an extended 18 mm contact sleeve.
    Check before use: conductor cross-section, required contact length, terminal depth, crimping tool compatibility and equipment connection requirements.
    Important reminder: 18 mm is the length of the metal contact sleeve. The overall length of this model is 25.0 mm.

    FAQ

    1. What conductor size is APF-2,50/18 designed for?
    It is designed for a 2.5 mm² stranded conductor.
    2. Is 18 mm the total ferrule length?
    No. 18 mm is the metal contact sleeve length. The overall length is 25.0 mm.
    3. What is the insulated collar for?
    It helps guide the conductor into the metal sleeve and forms a neat transition between the conductor insulation and the crimped metal section.
    4. Does the ferrule need to be crimped?
    Yes. It is intended for crimped installation using suitable ferrule crimping pliers for the relevant conductor size.
    5. When is the extended 18 mm version useful?
    When the terminal design requires a longer formed contact section than a shorter standard ferrule provides.
    6. How many ferrules are in the pack?
    100 pcs.

    APF-2,50/18 | 2.5 mm² | 18 mm | grey | 100 pcs.

    Extended insulated ferrule for professional preparation of 2.5 mm² stranded conductor ends. Metal contact sleeve length – 18 mm, overall length – 25.0 mm. Suitable for panel, automation and other electrical wiring applications where a longer crimped contact section is required.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals

    privacy policy

    Information