Products catalog

  • Industrial | digital wind speed | direction sensor | anemometer | 10A | 230V/12V | 0-70m/s | with acoustic and visual alarm signal | stationary | Zigbee

    Code: ES-YGC-FBY

    Industrial wind speed and direction sensor-anemometer with Zigbee wireless communication, audible and visual alarm, and 10 A relay output (NO/COM/NC). Measures wind speed within a 0–70 m/s range. When the preset limit is exceeded, the system activates an alarm and can control external safety equipment. Powered from a 230 V AC supply via a 12 V DC adapter. Designed for tower cranes, construction sites, industrial facilities, and other stationary wind monitoring systems. 

  • Industrial Wind Speed and Direction Sensor Anemometer YGY-FBY | Zigbee | 10A Relay | Sound & Light Alarm | SID-03

    Industrial Wind Speed and Direction Sensor-Anemometer | Zigbee Communication | Sound & Light Alarm Controller | 10A Relay

    Industrial Combined Anemometer – is a professional wind speed and direction monitoring and alarm system designed for tower cranes, construction sites, industrial facilities, and outdoor systems. The device features thermistor measurement, ABS wind cups, real-time display indication, sound and light alarm, and a relay control output.

    Industrial Wind Monitoring System with Alarm Controller

    The system measures wind speed up to 70 m/s with an extremely low starting threshold (≤ 0.8 m/s). The main controller displays real-time wind speed and wind scale grades, and upon exceeding the set threshold (0–35 m/s or 0–12 grades), it triggers a sound and light alarm while switching 10A relay contacts to control external equipment or crane safety systems.

    0–70 m/s
    Measurement Range
    Zigbee
    Wireless Data Link
    10A Relay
    NO / COM / NC Output
    AC 230V/12V
    Power Supply with Adapter

    Connection and Construction Groups – What Does the Installer Connect?

    Element Purpose Engineering Note
    Outdoor Sensor (Wind Cups / Vane) Wind speed and direction measurement under outdoor conditions Made of durable ABS plastic using a thermistor measurement principle. Includes a 2.5 m cable.
    Controller (Alarm Host) Data display, sound/light alarm, and settings management Dimensions: 152.5 × 90.5 × 55 mm. Displays working status, wind speed, and wind grades.
    Relay Junction Box High-power external equipment switching Dimensions: 107 × 58 × 33 mm. Equipped with a 0.5 m connection cable. Terminals: NO, COM, NC.
    Power Supply Group (AC 230V to DC 12V) System power supply from mains via power adapter Includes a 1-meter power cable with adapter.
    Zigbee Wireless Module Wireless data transmission to centralized systems Allows wireless transmission of measurement data to remote monitoring points.

    How Does the Wind Speed and Direction Anemometer Work?

    1. As airflow turns the durable ABS wind cups and aligns the vane, the thermistor sensor detects flow changes starting from as low as ≤ 0.8 m/s speed.
    2. The signal is transmitted to the main controller via the 2.5 m sensor cable (or Zigbee wireless channel).
    3. The controller screen displays real-time wind speed in m/s and wind strength in grades (0–12 scale).
    4. When wind speed exceeds the user-configured limit (0–35 m/s), the integrated sound and light (acousto-optic) alarm is activated.
    5. Simultaneously, the controller switches the 10A relay contacts (NO/COM/NC) via the junction box to automatically shut down the crane or activate external safety systems.

    Alarm Settings and Relay Output Specifications

    Parameter / Component Setting Ranges / Specification Functional Purpose
    Wind Speed Alarm Threshold 0–35 m/s (adjustable in 1 m/s increments) Precise setting of the critical wind limit based on facility safety requirements.
    Wind Grade Alarm Threshold 0–12 grades (adjustable in 1 grade increments) Simplified hazardous wind level setting based on the Beaufort scale.
    Relay Contact Rating 10A 250VAC (50/60Hz) / 10A 30VDC / 10A 28VDC Allows direct control of powerful industrial contactors, siren circuits, or emergency crane stopping systems.
    Relay Terminals NO (Normally Open), COM (Common), NC (Normally Closed) Universal connection capability for both circuit disconnection and alarm triggering.
    Tower Crane and Industrial Safety

    Working at high altitudes makes wind gusts a direct risk to crane stability. The system provides immediate operator warning via bright flashing lights and a loud acoustic siren, while automatically interlocking hazardous crane movements through the 10A relay when permissible wind speed is exceeded.

    Technical Specifications

    Model Wind Speed and Direction Alarm Warning System
    Measurement Principle Industrial Thermistor Measurement
    Measurement Range 0 – 70 m/s
    Starting Wind Speed ≤ 0.8 m/s
    Measurement Accuracy ± (0.5 + 0.02V) m/s (where V is actual wind speed)
    Power Supply AC 230V to DC 12V power adapter (1 m cable)
    Wireless Communication Zigbee protocol
    Sensor Cable Length 2.5 meters
    Junction Box Cable Length 0.5 meters
    Relay Contact Parameters 10A 250VAC (50/60Hz), 10A 30VDC, 10A 28VDC
    Alarm Host Dimensions 152.5 × 90.5 × 55 mm
    Relay Junction Box Dimensions 107 × 58 × 33 mm
    Operating Environment Temperature: -20°C to 60°C; Humidity: 20% RH to 90% RH (non-condensing)
    Wind Cup Material High-durability ABS plastic

    Pros / Advantages

    • Wide measurement range (0–70 m/s): allows monitoring of everything from light breezes to hurricane-force winds.
    • Wireless Zigbee integration: convenient data transmission to industrial monitoring systems.
    • Powerful 10A relay: 3-terminal (NO/COM/NC) output allows direct control of external devices.
    • Clear indication and alarm: acoustic and visual signals immediately alert personnel when limits are exceeded.
    • High sensitivity: responds to wind movement starting as low as ≤ 0.8 m/s speed.
    • Durable ABS construction: outdoor sensor cups are resistant to atmospheric exposure and UV radiation.

    Cons / Limitations

    • Stationary AC 230V power supply: requires an AC mains supply (although the controller operates via a 12V adapter).
    • Operating temperature range: the sensor is rated for operation between -20°C and +60°C.
    • Cable length constraint: standard sensor cable is 2.5 m (for longer distances, using Zigbee communication is recommended).

    Applications / Suitable For

    • Tower crane and hoisting equipment safety systems
    • Construction sites, high-rise buildings, and scaffolding safety monitoring
    • Ports, yacht clubs, and shipping terminals
    • Meteorological stations, commercial greenhouses, and solar farm installations

    Not Suitable For

    • Extreme arctic conditions where temperatures drop below -20°C (without additional heating elements)
    • Handheld portable measurements (the device is designed for stationary industrial installation)

    Practical Example – Tower Crane Safety Management

    The weather-resistant ABS wind sensor with vane is mounted at the top of a tower crane, while the alarm controller is placed inside the operator cab. With an alarm threshold set to 15 m/s, if the wind intensifies, the controller immediately activates a flashing red light and sound siren to alert the operator. Simultaneously, the 10A relay NC contact opens to disconnect power to the crane's slewing motor control, preventing hazardous operating conditions.

    Installation and Commissioning Sequence

    1. Mount the outdoor wind sensor (cups and vane) at the highest point of the monitored object where airflow is unobstructed.
    2. Run the 2.5 m sensor cable to the alarm controller or configure the wireless Zigbee connection.
    3. Install the alarm controller unit in a location easily visible to the operator.
    4. Connect the relay junction box to the controller and wire the NO/COM/NC terminals to the external control circuit.
    5. Plug the power adapter into an AC 230V mains socket (outputting 12V DC).
    6. Use the controller buttons to set the desired wind speed (m/s) or wind grade (0–12) alarm threshold and test system functionality.

    Frequently Asked Questions (FAQ)

    How is the alarm threshold adjusted?

    The alarm controller allows setting the wind speed limit from 0 to 35 m/s (in 1 m/s steps) or wind grade from 0 to 12 (in 1 grade steps).

    What load capacity can the relay switch?

    The integrated relay supports up to 10A at 250VAC or 10A at 30VDC/28VDC, enabling direct control of powerful industrial contactors or sirens.

    What are the benefits of Zigbee connectivity?

    The Zigbee protocol enables wireless data transmission of wind measurement readings to remote industrial monitoring or SCADA systems.

    Is the sensor resistant to harsh outdoor weather?

    Yes, the ABS wind cups and housing are fully rated for outdoor operation in temperatures ranging from -20°C to 60°C.

    Installer's Note

    When mounting the wind sensor on a tower crane or mast, ensure that the outdoor vane and cups are perfectly vertical and free from any mechanical obstructions within a 360-degree radius. When wiring NC/NO relay contacts into the crane safety loop, always verify operation in test mode prior to starting hoisting operations.

    Industrial Wind Speed and Direction Anemometer with Zigbee connectivity provides precise wind measurement (0–70 m/s), real-time acoustic and visual alerts, and reliable 10A relay control for tower cranes and industrial applications.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information