Products catalog

  • Interposing relay | 12 V DC coil | 1CO (SPDT) | 8 A | plug-in | LANBOO J13A | ES-J13A

    Code: ES-J13A

    LANBOO J13A plug-in interposing relay: 12 V DC coil, 1CO (NO + NC) 8 A. Mounts in a socket.

  • Interposing relay | 12 V DC coil | 1CO (SPDT) | 8 A | plug-in | LANBOO J13A | ES-J13A

    LANBOO J13A is a plug-in electromechanical interposing relay for control circuits: 12 V DC coil and one changeover contact (NO + NC with a common terminal) rated up to 8 A. The relay plugs into a matching socket, so it can be replaced quickly without disconnecting any wires.

    Key point:
    A plug-in relay is a practical choice for panels where fast servicing matters: a faulty relay is replaced in seconds. The 8 A contact suits most control circuits – contactor coils, signal lamps and small loads.
    Coil
    12 V DC
    Contact
    1CO (SPDT) – NO + NC
    Contact current
    8 A
    Test button
    no

    Operating principle

    The relay plugs into a socket mounted on a DIN rail or panel. The control signal connects to the coil terminals, and the load circuit to the common (COM), NO and NC terminals.

    When 12 V DC is applied to the coil, the contact changes over: COM connects to NO and disconnects from NC. When the signal is removed, the contact returns to its initial position.

    Result: the controller is loaded only by the coil current, while the load is switched by an isolated contact.

    Why choose the LANBOO J13A?
    The plug-in design shortens repair time, silver alloy contacts suit control circuits.

    Technical specifications

    Product type Plug-in electromechanical interposing relay
    Manufacturer / code LANBOO / ES-J13A
    Series J13A
    Coil voltage 12 V DC
    Contact configuration 1CO (SPDT): 1 NO + 1 NC with common terminal
    Contact current 8 A
    Contact material silver alloy
    Manual test button no
    Housing sealed, transparent plastic
    Mounting in socket (socket sold separately)

    Key functions

    • Signal isolation – protects the controller from the load circuit.
    • NO/NC changeover contact – switching on or off with a single relay.
    • Plug-in design – fast replacement without disconnecting wires.
    • Sealed housing – protects the mechanism from dust.

    Where is it used?

    • Control cabinets and automation panels
    • PLC output expansion
    • Driving coils of contactors and magnetic starters
    • Signalling and alarm circuits
    • Pump, fan and heating control
    • Gate, barrier and lighting automation

    Use by need

    For control cabinet manufacturers.
    Plug-in relays allow the panel to be assembled and tested first, with relays inserted at the final stage.
    For maintenance teams.
    A faulty relay is replaced in seconds without disconnecting wires.
    For commissioning engineers.
    A simple relay without mechanical accessories – for when manual operation is unnecessary or even undesirable.

    Practical application

    If a controller 12 V DC output has to drive a contactor coil, connect the output to the J13A coil and route the contactor coil through the COM–NO contact. If the relay fails, simply pull it out of the socket and replace it.

    Pros

    • Plug-in – fast replacement
    • 1 changeover contact NO + NC
    • 8 A contact current
    • Silver alloy contacts
    • Sealed housing

    Cons / limitations

    • Requires a matching J13A socket – not included
    • Contact current up to 8 A – larger loads require a contactor
    • Inductive loads require a current margin
    • No manual test button – if you need one, choose the version with a button

    Safety and installation notes

    • Disconnect the load circuit voltage before installing or replacing the relay.
    • The coil voltage must match the control signal: 12 V DC.
    • Use only the socket designed for this relay – an unsuitable socket may not ensure proper contact.
    • Installation must be carried out by a qualified electrician.

    Quick selection guide

    Coil: 12 V DC
    1CO (SPDT)
    8 A
    Plug-in
    Without test button
    Suitable when you need to:
    • drive a contactor coil or signal lamp from a controller
    • have quickly replaceable relays in the panel
    • use a simple relay without mechanical accessories
    Check before use:
    • control signal voltage – 12 V DC
    • whether you have a J13A series socket
    • load current and type
    Important reminder: A relay is not a protective device – it does not protect against overload or short circuit.

    FAQ

    Is the socket included?
    No, the relay is sold without a socket – ask our sales managers about a matching socket.
    What does 1NO + 1NC mean?
    It is one changeover contact with a common terminal: normally open and normally closed outputs.
    What current can the contact switch?
    Up to 8 A.
    Is there a version with a test button?
    Yes, the same relay is also available with a manual test button.
    Is it suitable for a PLC output?
    Yes, if the PLC output voltage is 12 V DC.
    Does the relay protect against overload?
    No, the circuit must be protected by a circuit breaker or fuse.

    Interposing relay | 12 V DC coil | 1CO (SPDT) | 8 A | plug-in | LANBOO J13A | ES-J13A

    LANBOO J13A plug-in interposing relay: 12 V DC coil, 1CO 8 A contact with silver alloy contacts – for control circuits, PLCs and automation panels.

    Published: 2026-11-05 · Data verified against the supplier's specification and product marking: 2026-11-05

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Modular photo relay | twilight switch with external sensor | 16 A | 12–240 V AC/DC | 1–50,000 lx | 1CO | DIN | GanzKK | SOU-1/UNI
    Code: SOU-1/UNI

    DIN rail twilight switch with universal 12–240 V AC/DC supply and external sensor: 1–50,000 lx, 1CO 16 A AC1, 0–2 min delay, 1 module.

    Price 42.47 € VAT incl.
    ( 35.10 € VAT excl. )
  • privacy policy

    Information