Products catalog

  • Modular interface relay | 3×SPDT | 16 A AC1 | 230 V AC coil | LED | DIN 18 mm | GEYA GR8-316

    Code: ESGR8-316

    Modular GEYA GR8-316 interface relay with 3 changeover contacts (16 A AC1) and 230 V AC coil. One 18 mm DIN module with LED status indication – for isolating control signals, multiplying contacts and driving contactor coils in panels.

  • Modular interface relay | 3×SPDT | 16 A AC1 | 230 V AC coil | LED | DIN 18 mm | GEYA GR8-316

    Modular GEYA GR8-316 interface relay with 3 changeover contacts (SPDT / CO) rated 16 A AC1. It mounts on a 35 mm DIN rail, takes one 18 mm module and lets a single control signal switch separate circuits, isolate a controller output from the load and multiply the number of contacts. The 230 V AC coil lets the relay be driven directly by mains-voltage signals – timers, thermostats, switches or other 230 V control devices.

    Key point:
    Choose the GR8-316 when one control signal has to switch 3 independent circuits and everything must fit into a single module width. The contacts are rated for up to 16 A resistive (AC1) load at 250 V AC – motors and other large inductive loads must be switched via a contactor, not directly.
    Coil
    230 V AC
    Contacts
    3×SPDT (CO)
    Contact current
    16 A AC1, 250 V AC
    Mounting
    DIN 35 mm, 1 module (18 mm)

    Operating principle

    The relay mounts on a 35 mm DIN rail (EN/IEC 60715) in a distribution box or automation panel. The control voltage is applied to coil terminals A1–A2, and the controlled circuits are connected to contact groups 11-12-14, 21-22-24 and 31-32-34: 11/21/31 – common, 12/22/32 – normally closed (NC), 14/24/34 – normally open (NO).

    When control voltage is applied, the coil pulls in the armature and all 3 contacts change over simultaneously – within max. 40 ms. A red LED shows that the relay is energised. When control voltage is removed, the contacts return to their initial position (within max. 200 ms).

    Coil and contact circuits are electrically isolated, so the control side can run on a different voltage than the switched circuit – for example, a low-voltage controller can safely switch a 230 V circuit.

    Why the GR8-316?
    One 18 mm module, 3 changeover contacts and LED indication: the GR8-316 replaces a relay with a separate socket and takes less panel space. Wires connect directly to the screw terminals.

    Technical specifications

    Product type Modular interface (auxiliary) relay
    Manufacturer GEYA
    Model GR8-316 (230 V AC)
    Product code ESGR8-316
    Coil (control) voltage 230 V AC (A1–A2)
    Coil consumption AC max. 6 VA
    Control voltage tolerance −15 % / +10 %
    Contacts 3×SPDT (changeover, CO)
    Rated contact current 16 A (AC1)
    Switching voltage 250 V AC / 24 V DC
    Min. switching power (DC) 500 mW
    Changeover time max. 40 ms
    Reset time max. 200 ms
    Status indication red LED
    Mechanical life 1×10⁷ cycles
    Electrical life (AC1) 1×10⁵ cycles
    Operating temperature −20…+55 °C
    Storage temperature −35…+75 °C
    Protection degree IP40 (front), IP20 (terminals)
    Mounting 35 mm DIN rail (EN/IEC 60715), any position
    Dimensions 90 × 18 × 64 mm (1 module)
    Terminals solid wire max. 1×2.5 mm² or 2×1.5 mm²; with ferrule max. 1×2.5 mm²
    Overvoltage category / pollution degree III / 2

    Main functions

    • 3 changeover contacts – one signal controls 3 independent circuits, NO and NC logic available.
    • 16 A AC1 contacts – can directly switch resistive loads up to 16 A, e.g. heating elements.
    • 230 V AC coil – driven directly by mains-voltage signals, no extra power supply needed.
    • Galvanic isolation – the controller or sensor output is separated from the switched circuit.
    • LED indication – relay status visible at a glance, faster diagnostics.
    • Single module – the 18 mm wide housing saves space in the distribution panel.

    Where is it used?

    • Isolating PLC and controller outputs from load circuits
    • Driving coils of contactors and motor starters
    • HVAC systems – control of fans, dampers and pumps
    • Lighting control from timers, thermostats or twilight switches
    • Passing alarm and status signals to another system (dry contact)
    • Home and building distribution boards – load control by timer, thermostat or voltage relay

    Use by need

    For home panel installers.
    A 230 V timer or thermostat signal can control up to three separate circuits.
    For building managers.
    Lighting, heating or ventilation circuits controlled from one 230 V signal.
    For electricians.
    16 A contacts switch resistive loads directly without a separate contactor.

    Practical application

    If a 230 V timer must switch on a heating element and a pilot lamp and signal the ventilation, the GR8-316 with 230 V coil does it from one signal: each of the three 16 A contacts switches a separate circuit.

    Advantages

    • 3 changeover contacts in one 18 mm module
    • 16 A AC1 contact current at 250 V AC
    • Red LED status indicator
    • Coil and contacts electrically isolated
    • No separate socket needed – screw terminals up to 2.5 mm²
    • Driven directly by 230 V mains signals

    Drawbacks / limitations

    • DC contact switching voltage only up to 24 V
    • Not intended for direct motor starting – use a contactor
    • No manual test button, relay not replaceable separately – the whole module is replaced if it fails
    • For three-phase power loads use a contactor – contact rated voltage is 250 V AC
    • Cannot be driven directly by a 24 V PLC output – choose a 24 V coil relay for that

    Safety and installation notes

    • Switch off the supply and verify absence of voltage before installation.
    • Check the coil voltage on the housing: 230 V AC (A1–A2).
    • Coil terminals A1–A2 carry 230 V – work only with the supply disconnected.
    • Do not exceed 16 A AC1 and the 250 V AC / 24 V DC switching limits.
    • For inductive loads (contactor coils, valves) use suppression: DC – a diode, AC – an RC snubber or varistor.
    • Size wires for the current; max. 2.5 mm² per terminal.
    • Installation and connection must be carried out by a qualified electrician.

    Quick selection guide

    230 V AC
    3×SPDT (CO)
    16 A AC1
    1 DIN module 18 mm
    LED indication
    Suitable when you need to:
    • control 3 circuits from one signal
    • isolate a controller output from the load
    • drive a contactor coil
    • control from a 230 V timer, thermostat or switch
    Check before use:
    • control voltage and its type (AC or DC)
    • load type and current – up to 16 A AC1
    • that DC switching voltage does not exceed 24 V
    • that one free module is available in the panel
    Important reminder: An interface relay is not a protective device: it does not protect against overload or short circuit, so the circuit must be protected by a circuit breaker or fuse.

    FAQ – frequently asked questions

    What is the coil control voltage?
    230 V AC (A1–A2).
    Is it suitable for a 24 V PLC output?
    No – the coil is 230 V AC; for 24 V DC control choose a 24 V coil relay.
    Can a motor be connected directly?
    No – the relay drives the contactor coil, and the contactor switches the motor.
    How much panel space does it take?
    One module – 18 mm on the DIN rail.
    Can it switch a DC load?
    Yes, but the DC contact switching voltage is only up to 24 V.
    Is a separate relay socket needed?
    No – wires connect directly to the screw terminals.

    Modular interface relay | 3×SPDT | 16 A AC1 | 230 V AC coil | LED | DIN 18 mm | GEYA GR8-316

    GEYA GR8-316 – modular interface relay with 3 changeover 16 A AC1 contacts and 230 V AC coil. One 18 mm DIN module, LED indication and galvanic isolation – for reliable signal transfer and contactor control in automation and distribution panels.

    Published: 2026-11-05 · Data verified against the manufacturer datasheet: 2026-11-05

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Modular photo relay | twilight switch with external sensor | 16 A | 12–240 V AC/DC | 1–50,000 lx | 1CO | DIN | GanzKK | SOU-1/UNI
    Code: SOU-1/UNI

    DIN rail twilight switch with universal 12–240 V AC/DC supply and external sensor: 1–50,000 lx, 1CO 16 A AC1, 0–2 min delay, 1 module.

    Price 42.47 € VAT incl.
    ( 35.10 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information