  • Modular interface relay | 3×SPDT | 8 A AC1 | 12 V AC/DC coil | LED | DIN 18 mm | GEYA GR8-308

    Code: ESGR8-3161

    Modular GEYA GR8-308 interface relay with 3 changeover contacts (8 A AC1) and 12 V AC/DC coil. One 18 mm DIN module with LED status indication – for isolating control signals, multiplying contacts and driving contactor coils in panels.

  • Modular interface relay | 3×SPDT | 8 A AC1 | 12 V AC/DC coil | LED | DIN 18 mm | GEYA GR8-308

    Modular GEYA GR8-308 interface relay with 3 changeover contacts (SPDT / CO) rated 8 A AC1. It mounts on a 35 mm DIN rail, takes one 18 mm module and lets a single control signal switch separate circuits, isolate a controller output from the load and multiply the number of contacts. The 12 V AC/DC coil suits control from 12 V power supplies, battery systems and 12 V controller outputs.

    Key point:
    Choose the GR8-308 when one control signal has to switch 3 independent circuits and everything must fit into a single module width. The contacts are rated for up to 8 A resistive (AC1) load at 250 V AC – motors and other large inductive loads must be switched via a contactor, not directly.
    Coil
    12 V AC/DC
    Contacts
    3×SPDT (CO)
    Contact current
    8 A AC1, 250 V AC
    Mounting
    DIN 35 mm, 1 module (18 mm)

    Operating principle

    The relay mounts on a 35 mm DIN rail (EN/IEC 60715) in a distribution box or automation panel. The control voltage is applied to coil terminals A1–A2, and the controlled circuits are connected to contact groups 11-12-14, 21-22-24 and 31-32-34: 11/21/31 – common, 12/22/32 – normally closed (NC), 14/24/34 – normally open (NO).

    When control voltage is applied, the coil pulls in the armature and all 3 contacts change over simultaneously – within max. 40 ms. A red LED shows that the relay is energised. When control voltage is removed, the contacts return to their initial position (within max. 200 ms).

    Coil and contact circuits are electrically isolated, so the control side can run on a different voltage than the switched circuit – for example, a low-voltage controller can safely switch a 230 V circuit.

    Why the GR8-308?
    One 18 mm module, 3 changeover contacts and LED indication: the GR8-308 replaces a relay with a separate socket and takes less panel space. Wires connect directly to the screw terminals.

    Technical specifications

    Product type Modular interface (auxiliary) relay
    Manufacturer GEYA
    Model GR8-308 (12 V AC/DC)
    Product code ESGR8-3161
    Coil (control) voltage 12 V AC/DC (A1–A2)
    Coil consumption AC max. 12 VA / DC max. 1.9 W
    Control voltage tolerance −15 % / +10 %
    Contacts 3×SPDT (changeover, CO)
    Rated contact current 8 A (AC1)
    Switching voltage 250 V AC / 24 V DC
    Min. switching power (DC) 500 mW
    Changeover time max. 40 ms
    Reset time max. 200 ms
    Status indication red LED
    Mechanical life 1×10⁷ cycles
    Electrical life (AC1) 1×10⁵ cycles
    Operating temperature −20…+55 °C
    Storage temperature −35…+75 °C
    Protection degree IP40 (front), IP20 (terminals)
    Mounting 35 mm DIN rail (EN/IEC 60715), any position
    Dimensions 90 × 18 × 64 mm (1 module)
    Terminals solid wire max. 1×2.5 mm² or 2×1.5 mm²; with ferrule max. 1×2.5 mm²
    Overvoltage category / pollution degree III / 2

    Main functions

    • 3 changeover contacts – one signal controls 3 independent circuits, NO and NC logic available.
    • 8 A AC1 contacts – enough for pilot lamps, contactor coils, valves and small resistive loads.
    • 12 V AC/DC coil – works with both AC and DC 12 V control voltage.
    • Galvanic isolation – the controller or sensor output is separated from the switched circuit.
    • LED indication – relay status visible at a glance, faster diagnostics.
    • Single module – the 18 mm wide housing saves space in the distribution panel.

    Where is it used?

    • Isolating PLC and controller outputs from load circuits
    • Driving coils of contactors and motor starters
    • HVAC systems – control of fans, dampers and pumps
    • Lighting control from timers, thermostats or twilight switches
    • Passing alarm and status signals to another system (dry contact)
    • 12 V systems: gate automation, security alarms, off-grid and battery systems

    Use by need

    For gate and security system installers.
    A weak 12 V controller output switches lighting, a siren or another circuit.
    For off-grid and solar system installers.
    Loads and status signals controlled by a 12 V signal without extra converters.
    For automation integrators.
    Three contacts from one 12 V output – several control actions at once.

    Practical application

    If a gate controller or 12 V alarm panel has a weak output, the GR8-308 with 12 V coil can, from one signal, switch on lighting (first NO contact), pass a signal to another system (second NO) and block another function through an NC contact.

    Advantages

    • 3 changeover contacts in one 18 mm module
    • 8 A AC1 contact current at 250 V AC
    • Red LED status indicator
    • Coil and contacts electrically isolated
    • No separate socket needed – screw terminals up to 2.5 mm²
    • 12 V AC/DC coil – works with AC and DC control

    Drawbacks / limitations

    • DC contact switching voltage only up to 24 V
    • Not intended for direct motor starting – use a contactor
    • No manual test button, relay not replaceable separately – the whole module is replaced if it fails
    • 8 A AC1 – for larger resistive loads choose a 16 A relay
    • 12 V coil only – for 24 V control choose a 24 V coil relay

    Safety and installation notes

    • Switch off the supply and verify absence of voltage before installation.
    • Check the coil voltage on the housing: 12 V AC/DC (A1–A2).
    • Do not apply more than 12 V to the coil (tolerance −15 % / +10 %).
    • Do not exceed 8 A AC1 and the 250 V AC / 24 V DC switching limits.
    • For inductive loads (contactor coils, valves) use suppression: DC – a diode, AC – an RC snubber or varistor.
    • Size wires for the current; max. 2.5 mm² per terminal.
    • Installation and connection must be carried out by a qualified electrician.

    Quick selection guide

    12 V AC/DC
    3×SPDT (CO)
    8 A AC1
    1 DIN module 18 mm
    LED indication
    Suitable when you need to:
    • control 3 circuits from one signal
    • isolate a controller output from the load
    • drive a contactor coil
    • control from a 12 V AC or DC source
    Check before use:
    • control voltage and its type (AC or DC)
    • load type and current – up to 8 A AC1
    • that DC switching voltage does not exceed 24 V
    • that one free module is available in the panel
    Important reminder: An interface relay is not a protective device: it does not protect against overload or short circuit, so the circuit must be protected by a circuit breaker or fuse.

    FAQ – frequently asked questions

    What is the coil control voltage?
    12 V AC/DC (A1–A2).
    Is it suitable for a PLC output?
    Yes, if the output is 12 V; coil consumption is up to 1.9 W (about 160 mA), so check the output current rating.
    Can a motor be connected directly?
    No – the relay drives the contactor coil, and the contactor switches the motor.
    How much panel space does it take?
    One module – 18 mm on the DIN rail.
    Can it switch a DC load?
    Yes, but the DC contact switching voltage is only up to 24 V.
    Is a separate relay socket needed?
    No – wires connect directly to the screw terminals.

    Modular interface relay | 3×SPDT | 8 A AC1 | 12 V AC/DC coil | LED | DIN 18 mm | GEYA GR8-308

    GEYA GR8-308 – modular interface relay with 3 changeover 8 A AC1 contacts and 12 V AC/DC coil. One 18 mm DIN module, LED indication and galvanic isolation – for reliable signal transfer and contactor control in automation and distribution panels.

    Published: 2026-11-05 · Data verified against the manufacturer datasheet: 2026-11-05

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products