Lightning discharge counter | lightning protection impulse counter | 0–999999 | 3–100 kA | no power supply required | IP67 | metal housing | for outdoor installation
Code: ES-OBVG-3MLightning discharge counter designed for counting lightning discharges, impulse overvoltages, and activations of the lightning protection system. The counter is installed on the lightning protection down conductor and records impulses from 3 kA to 100 kA. The mechanical counter operates without an additional power supply, making it a reliable solution for outdoor conditions where simple, durable, and easily verifiable lightning protection system monitoring is required.
-
Technical specifications
Product type: lightning strike counter / lightning protection impulse counter
Purpose: counting lightning discharges and impulses
Counter type: mechanical counter
Display / indication type: mechanical digital counter
Counting range: 0–99999 impulses
Recording capacity: up to 99999 lightning impulses
Minimum detectable impulse: 3 kA, 8/20 µs
Maximum detectable impulse: 100 kA, 10/350 µs
Sensitivity: from 3 kA
Power source: not required
Operation: without external power supply
Reset function: resettable model
Data storage: more than 10 years
Housing: metal / steel housing
Mounting parts: steel mounting components
Colour: grey / metallic colour
Operating environment: outdoor conditions
Operating temperature: from -20 °C to +65 °C
Protection class: IP67
External dimensions: approx. 150 x 40 x 70 mm
Mounting bracket / clamp width: approx. 150 mm
Fixing: to the lightning protection down conductor
Installation: on a lightning rod or lightning protection down conductor systemFunctions
Lightning impulse counting – records lightning discharges or strong impulses passing through the lightning protection system.
Mechanical counter – allows the number of recorded impulses to be clearly viewed without additional equipment.
Counting range 0–99999 – can store a large number of impulses, making it suitable for long-term maintenance of a lightning protection system.
Impulse detection from 3 kA – records lightning discharges and stronger impulse overvoltages from the specified current threshold.
Maximum detectable impulse current up to 100 kA – designed to register strong lightning current impulses.
Operation without power supply – no batteries, wired power supply or additional electrical connection required.
Visual control of the lightning protection system – after a storm, it is possible to quickly check whether the system was affected by a lightning discharge.
Reset function – the counter can be reset if this is provided in the specific model version.
Installation on the down conductor – mounted on the lightning protection down conductor to record impulses passing through the system.
Suitable for outdoor conditions – designed for outdoor use where the device is exposed to moisture, temperature fluctuations and atmospheric conditions.
Durable metal housing – protects the internal mechanism from mechanical impact and environmental factors.Use
For household users: suitable for private houses, homesteads, garages or utility buildings with an installed lightning protection system. The counter allows the user to check after a storm whether the lightning rod was affected by a lightning discharge.
For electricians: used when installing or maintaining lightning rods, grounding systems and surge protection systems. Helps to quickly assess whether an additional system inspection is required after a storm.
For engineers / designers: relevant when designing lightning protection systems for industrial, commercial, energy or solar power plant facilities where lightning impulse recording and system monitoring are required.
For maintenance specialists: useful for regular inspection of lightning protection systems in buildings, towers, antennas, solar power plants or industrial facilities. If the counter reading has changed, inspection of grounding, connections and surge protection can be planned.
For industrial and commercial facilities: suitable for factories, warehouses, office buildings, communication towers, power plants and other facilities where it is important to know whether the lightning protection system has been activated.
Advantages
Operates without a power source – no batteries, 230 V power supply or additional electrical connection required.
Mechanical counter – simple and clear reading of indications.
Records up to 99999 impulses – large counter capacity for long-term use.
Detects impulses from 3 kA – suitable for recording lightning discharges.
Maximum detectable impulse up to 100 kA – suitable for strong lightning impulses.
Suitable for outdoor conditions – operates in atmospheric conditions from -20 °C to +65 °C.Disadvantages
Not intended as a standalone lightning protection device – it only counts impulses and does not itself divert lightning or protect equipment from overvoltages.
The installation location must be selected correctly – an incorrectly installed counter may fail to record impulses or may show inaccurate data.
No remote monitoring function – this is a mechanical counter, so the readings must be checked visually.FAQ
What is a lightning discharge counter used for?
It is used to count lightning discharges or strong impulses passing through a lightning protection system. This helps to determine whether the lightning rod or lightning protection system has been affected by lightning.Does the counter require power supply?
No, this model does not require an additional power source.Where is this counter installed?
It is installed on the down conductor of the lightning protection system so that it can record lightning impulses passing through the system. The exact installation location must be selected according to the lightning protection project and the manufacturer’s instructions.Is this counter suitable for outdoor use?
Yes, the device is specified as suitable for outdoor use. It operates within a temperature range from -20 °C to +65 °C.Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Potential equalization busbar | terminal | 4x15 | L+PEN | DIN | IEK | YND10-4-15-125 | 4606056048674Code: YND10-4-15-125Price 17.65 € VAT incl.( 14.59 € VAT excl. )Anti-corrosion paste | 0.5 kg | for grounding rod connections and contact protection | GalmarCode: 11301Price 10.12 € VAT incl.( 8.36 € VAT excl. )Surge protector PO I 1 280V/12.5kA 1P Class I+II+III (B+C+D) 12.5kA 1.3kVCode: SKU#158869360260671971Price 34.09 € VAT incl.( 28.18 € VAT excl. )