Products catalog

  • Automatic phase selector | 3F → 1F | 63 A | U> 230–300 V | U< 140–210 V | DIN | ELEAATS-D3-63A

    Code: ELEAATS-D3-63A

    The ELEAATS-D3-63A is an automatic phase selector: from a three-phase supply it feeds a single-phase load from whichever phase currently has a suitable voltage.

  • Automatic phase selector | 3F → 1F | 63 A | U> 230–300 V | U< 140–210 V | DIN | ELEAATS-D3-63A

    The ELEAATS-D3-63A is an automatic phase selector: from a three-phase supply it feeds a single-phase load from whichever phase currently has a suitable voltage. In addition to voltage, it measures the load current and disconnects the circuit when the set limit is exceeded.

    Key point:
    When one phase of a three-phase supply fails or drops, the most important single-phase equipment – boiler, pump, security system – keeps running from another phase without human intervention.
    Load current
    63 A
    Voltage limits
    U> 230–300 V · U< 140–210 V
    Network / supply
    3F+N, 3×230 V AC
    Functions
    current limit

    How it works

    The device is connected to three phases and neutral; the output provides one phase and neutral for the single-phase load. The voltage of each phase is measured.

    If the voltage of the phase in use leaves the set limits, the load is switched to another suitable phase; if no suitable phase is available, it is disconnected until at least one phase returns to normal.

    When the voltage returns, depending on the settings the load stays on that phase or is returned to the priority phase.

    Why choose the ELEAATS-D3-63A?
    Single-phase equipment keeps running even if one phase fails – no need to switch breakers by hand.

    Technical specifications

    Product type Automatic phase selector 3F → 1F with voltage monitoring
    Manufacturer / code ELEAATS-D3-63A
    Network 3F+N, 3×230 V AC
    Frequency 40 / 50 / 60 / 70 Hz
    Rated current 63 A
    Overvoltage limit U> (factory) 230–300 V
    Undervoltage limit U< (factory) 140–210 V
    Switch-on delay (factory) 1–600 s
    Return to priority phase 1–600 s
    Switching to backup phase < 0.2 s
    Hysteresis 5 V
    Voltage trip delay 0.1 s (> 350 V – 0.02 s)
    Measuring accuracy < 1 %
    Maximum phase voltage 350 V
    Mounting DIN 35 mm

    Main functions

    • Automatic phase selection – the single-phase load is switched to a suitable phase.
    • Current limit – an overloaded circuit is disconnected, the power drawn is limited.
    • Digital display or indication – the status is visible at once.

    Where is it used?

    • Gas and solid-fuel boilers
    • Borehole and circulation pumps
    • Security and CCTV systems
    • Servers, communication equipment
    • Refrigeration equipment
    • Country houses with an overhead line

    Use by need

    For the country house owner.
    Heating and water are not lost when a phase fails.
    For the facility administrator.
    Critical equipment runs without an electrician on duty.
    For the electrician.
    One device instead of manual phase switching.

    Practical use

    In a country house the gas boiler and borehole pump are supplied from one phase. If that phase fails, the ELEAATS-D3-63A automatically switches them to another phase – heating and water are not lost.

    Pros

    • Automatic phase selection
    • Fast switching
    • Voltage monitoring on each phase
    • DIN mounting

    Cons / limitations

    • Not suitable for three-phase loads
    • Does not replace circuit breakers and RCDs
    • Does not protect against lightning surges – an SPD is needed
    • The manufacturer does not publish a full datasheet – parameters per supplier specification

    Safety and installation notes

    • Install only after disconnecting the supply; work must be done by a qualified electrician.
    • A circuit breaker on each phase upstream of the device.
    • The load current must not exceed the device's rated current.
    • Check the neutral connection – without it the device will not work correctly.

    Quick selection guide

    3F → 1F
    63 A
    U> 230–300 V
    U< 140–210 V
    Suitable when you need:
    • to keep single-phase equipment running when a phase fails
    • to select a suitable phase automatically
    Check before use:
    • load current ≤ 63 A
    • whether the supply has an N conductor
    Important reminder: the selector does not replace circuit breakers and a surge protective device.

    FAQ

    Is it suitable for a three-phase load?
    No – the selector is intended for a single-phase load.
    How long does switching take?
    Depending on the model – from fractions of a second to a few seconds.
    Is a neutral needed?
    Yes – the device is connected as 3F+N.
    What is the maximum load?
    Up to 63 A.
    Does it return to the main phase?
    Depending on the model and settings – yes.
    Does it protect against lightning?
    No – an SPD is needed for that.

    Automatic phase selector | 3F → 1F | 63 A | U> 230–300 V | U< 140–210 V | DIN | ELEAATS-D3-63A

    ELEAATS-D3-63A – uninterrupted supply of single-phase equipment from a three-phase connection when a phase fails.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information