Modular three-phase multifunction energy meter | 100 A | 3×230/400 V | M-Bus | MID | DIN | VEXEN ESM3100DMB
Code: ESM3100DMBA three-phase multifunction meter for direct connection up to 100 A with M-Bus interface and MID certificate. Besides energy it shows voltage, current, power, power factor and THD.
-
Modular three-phase multifunction energy meter | 100 A | 3×230/400 V | M-Bus | MID | DIN | VEXEN ESM3100DMB
The VEXEN ESM3100DMB is a modular three-phase multifunction energy meter for direct connection in 3×230/400 V networks up to 100 A with M-Bus interface. It is designed for metering and network parameter monitoring in boards where data must be passed over an M-Bus network.
Key point:
In addition to kWh and kVArh the meter shows voltage, current, power, power factor, frequency and THD, so one device replaces both a meter and a simple network analyser. It is MID certified (EU-type examination certificate 0120/SGS0448).Max. current
100 AInterface
M-BusMeasurements
V, A, kW, PF, THDCertificate
MIDℹBidirectional metering
The manufacturer's documentation lists the measured values as kWh / kVArh, but separate import and export (consumed and delivered) energy registers are not explicitly named. If energy exported to the grid must be measured separately, confirm the register list before ordering; the confirmed import / export meter in this line is the ESM3100DM.Communication interfaces and integration
M-Bus (EN 13757-3)
Integration into an M-Bus automatic meter reading (AMR) system together with heat and water meters; primary (001–250) and secondary addressing, 300–9600 bps.For RS485 Modbus RTU systems
The manufacturer designates this model as the M-Bus version; for RS485 Modbus RTU integration choose the ESM3100DM2T.Operating principle
The meter is mounted on a 35 mm DIN rail and the phase conductors are connected directly (power terminals 4–25 mm²) – no current transformers are needed up to 100 A.
The electronic circuit measures the voltage and current of all phases and calculates power, energy and quality values.
Data are shown on the display and transmitted over M-Bus.
Why choose the VEXEN ESM3100DMB?
With one device you get MID energy metering plus remote visibility of load, phase voltages or THD. M-Bus lets the electricity meter share the same bus as heat and water meters.Technical specifications
Product type Modular three-phase multifunction energy meter Manufacturer / model VEXEN ESM3100DMB Connection Direct, up to 100 A Rated voltage 3×230/400 V AC Operating voltage range 80–120 % Un Basic current (Ib) 10 A Maximum current (Imax) 100 A Minimum current (Imin) 0.5 A Starting current / operating range 0.4 % Ib MID Yes (EU-type examination cert. 0120/SGS0448) Measured values Active and reactive energy (kWh, kVArh), active, reactive and apparent power (kW, kVAr, kVA), voltage, current, frequency, power factor, demand, THD Communication interface M-Bus (EN 13757-3) Communication settings M-Bus: 300–9600 bps, primary address 001–250, secondary address Terminals Power 4–25 mm² (2.5 Nm); auxiliary 0.5–1.5 mm² (0.2 Nm) Power consumption ≤ 2 W / 10 VA (voltage circuit); ≤ 4 VA (current circuit) Mounting 35 mm DIN rail Standards 2014/32/EU (MID), EN 50470-1, EN 50470-3 Main functions
- M-Bus interface – remote reading of registers and parameters.
- MID certificate – to EN 50470-1/-3, suitable for billing between parties.
- Multifunction measurements – V, A, kW, kVAr, kVA, PF, Hz, THD and demand.
- Direct connection up to 100 A – no current transformers.
- Active and reactive energy – kWh and kVArh registers.
- Bus addressing – primary and secondary M-Bus address.
How does it differ from similar models?
VEXEN ESM3100DMB2T Also M-Bus and multifunction, plus 2 tariffs by power source and 2 pulse outputs. VEXEN ESM3100DM2T Multifunction with 2 tariffs, but with RS485 Modbus RTU instead of M-Bus. VEXEN ESM3100DM Modbus RTU, import / export kWh, but no multifunction measurements. Eastron SDM630-MT 100 A, 4 tariffs, RS485 Modbus, MID; the ESM3100DMB is intended for M-Bus systems. Where is it used?
- Remote metering in commercial buildings and offices
- Sub-metering of apartment blocks and rented premises in M-Bus systems
- Building management systems (BMS)
- Production halls and equipment energy monitoring
- Heat substations and building services
- EV charging infrastructure
- Energy audits and load analysis
- Server rooms and technical rooms
Use by need
Facility managers.
The electricity meter is read over the same M-Bus as heat and water meters.Electricians and integrators.
Direct 100 A connection and a standard protocol – fewer components in the board.Energy managers.
Voltage, current, PF and THD help find overloaded phases and quality issues.Practical application
If an apartment block already runs an M-Bus reading system for heat and water meters, the VEXEN ESM3100DMB is connected to the same bus and electricity readings are collected together with the other meters.Pros
- MID certificate (EN 50470-1/-3)
- M-Bus interface
- Multifunction measurements including THD
- Direct connection up to 100 A
- Primary and secondary M-Bus addressing
- Power terminals 4–25 mm²
Cons / limitations
- This is the M-Bus version – for Modbus RTU systems choose the ESM3100DM2T
- The manufacturer does not name dual-source tariffs – for that choose the ESM3100DMB2T
- Separate import / export registers are not named in the manufacturer's documentation – separate import / export metering is confirmed for the ESM3100DM
- Currents above 100 A require a CT meter (ES3100DCT)
Safety and installation notes
- Installation and wiring must be done by a qualified electrician with the circuit isolated and verified dead.
- Install an upstream protective device (MCB or fuses) sized to the cable cross-section and load – the meter is not a protective device.
- Follow the phase and neutral wiring diagram in the manufacturer's manual; swapped inputs and outputs distort the readings.
- Tighten the power terminals to the specified torque – a loose contact at 100 A overheats and can damage the meter.
- Do not break the seals or open the front cover – this affects the measurement and, according to the manufacturer's manual, voids the warranty.
Quick selection guide
100 A directM-BusMultifunctionMIDSuitable when you need:- M-Bus remote reading
- multifunction network measurements
- MID metering up to 100 A
Check before use:- that the circuit current does not exceed 100 A
- that the M-Bus master supports EN 13757-3
- that there is enough space in the board
Important reminder: The meter measures and transmits data but performs no protective functions and does not replace the grid operator's billing meter without the operator's consent.FAQ
What interface does the ESM3100DMB have?
M-Bus to EN 13757-3, 300–9600 bps.Is the meter MID certified?
Yes, EU-type examination certificate 0120/SGS0448, EN 50470-1/-3.What is the maximum current?
Direct connection up to 100 A, basic current 10 A.Does it have 2 tariffs?
The manufacturer does not name dual-source tariffs for this model – the ESM3100DMB2T is intended for that.Does it measure energy exported to the grid?
Separate import / export registers are not named – we recommend the ESM3100DM or confirming the registers.What wire sizes fit?
Power terminals 4–25 mm² (2.5 Nm), auxiliary 0.5–1.5 mm² (0.2 Nm).VEXEN ESM3100DMB – multifunction M-Bus MID meter 100 A
The VEXEN ESM3100DMB is a three-phase multifunction 100 A meter with M-Bus and MID certificate, measuring energy, power, voltage, current, PF and THD.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThe IP protection class indicates the device's resistance to environmental factors.

The first digit indicates protection against dust and solid objects.
The second digit indicates protection against moisture.First digit values:
X — Untested;
0 — No protection;
1 — Protected against solid objects larger than 50 mm;
2 — Protected against solid objects larger than 12.5 mm;
3 — Protected against solid objects larger than 1 mm;
4 — Protected against solid objects larger than 1 mm;
5 — Dust protected;
6 — Totally dustproof.
Second digit values:X — Untested;
0 — No protection;
1 — Protected against vertically falling water drops;
2 — Protected against water drops falling at a 15º angle;
3 — Protected against rain falling at a 60º angle;
4 — Protected against water splashes;
5 — Protected against water jets;
6 — Protected against large amounts of water;
7 — Protected against short-term immersion in water up to 1 meter deep;
8 — Protected against long-term immersion in water up to 3 meters deep.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Write Review|2024-02-07 17:24:24Čia ne modbus, o m-bus (meter-bus). Tad aprašymas klaidinantis ("Elektros energijos apskaitos skaitiklis su MODBUS portu RTU ant DIN bėgelio") - jis netinka jungimui prie modbus rtu "linijos". Žodžiu suklaidintas vartotojas - išmesti pinigai! Alternative products