Products catalog

  • Modular digital multifunction time relay | 10 functions | 0.1s–999h | 5A | 24VAC/DC / 230VAC | DIN rail

    Code: ES-MCB-10
    Price 29.04 € VAT incl.
    ( 24.00 € VAT excl. )
    Buy more, pay less
    10+ pcs.  – 24.20 € for pcs. -16%

    Digital multifunction time relay – a universal DIN-rail relay designed for electrical and automation control circuits. It features 10 operating functions, an adjustable time range from 0.1 s to 999 h, an LCD display, an external T control input, and a 5A / 250V AC changeover contact. The relay can be powered by 230V AC or 24V AC/DC and is suitable for ON/OFF delay, pulse and cyclic ON/OFF control. 

  • Digital multifunction timer relay – 10 functions, 0.1 s–999 h, 5A, 230V AC / 24V AC/DC, DIN

    Digital multifunction timer relay designed for electrical and automation control circuits requiring ON-delay or OFF-delay operation, pulse control, cyclic ON/OFF operation or control by an external signal.

    The relay has 10 operating functions, an LCD display, external control input T and a wide adjustable time range from 0.1 seconds to 999 hours.

    What does this relay do?

    It combines several typical timer relay functions in one DIN module: ON-delay, OFF-delay, pulse control, control by T signal and cyclic ON/OFF operation. The operating mode and time are set digitally.

    Two supply voltage options

    The relay can be powered by 230V AC via terminals A1–A2 or alternatively by 24V AC/DC via terminals A2–A3. Operating frequency when using 230V AC supply – 50/60Hz.

    10
    Operating functions
    0.1 s–999 h
    Time range
    230V AC
    A1–A2 supply
    24V AC/DC
    A2–A3 alternative supply
    5A / 250V AC
    Resistive load
    LCD
    Digital setting

    Connection terminals

    Terminal Function Note
    A1 230V AC supply Used together with A2
    A2 Common supply terminal Common for A1–A2 or A2–A3 supply circuits
    A3 24V AC/DC alternative supply Used together with A2
    T External control / Trigger input 24–240V control signal; used in modes with external triggering
    1 / 2 / 3 Changeover relay contact NO / COM / NC – connect according to the wiring diagram shown on the specific device housing
    Important information about the supply terminals

    The relay has two alternative supply options: A1–A2 = 230V AC or A2–A3 = 24V AC/DC. The power supply must be connected according to the diagram shown on the housing of the specific device.

    Important information about the T control input

    Terminal T is not a simple dry contact input. A 24–240V control signal is specified for it. Before connecting a push button, sensor, PLC or other controller, its output type and voltage must be checked.

    10 operating functions

    The functions are designated A, b, C, d, E, F, G, H, L and n.

    Mode Function Operating principle
    A ON-delay When power is applied, the preset time starts counting. When the time expires, the relay output switches.
    b ON for a preset time When power is applied, the relay activates immediately and remains active for the preset time, after which it switches off.
    C ON-delay triggered by T signal When the T signal appears, timing starts. When the set time expires, the relay activates.
    d OFF-delay When the T signal disappears, the preset time starts counting, after which the relay switches off.
    E Pulse on rising edge of T signal When the T signal appears, the relay activates for the preset time.
    F Pulse on falling edge of T signal When the T signal disappears, the relay activates for the preset time.
    G ON / OFF delay Separate ON and OFF times can be configured.
    H Pulse ON / OFF control A change in the T signal starts the corresponding timing cycle.
    L Cyclic ON / OFF – starts with ON The relay operates cyclically: tON → tOFF → tON → tOFF.
    n Cyclic ON / OFF triggered by T The T signal starts cyclic ON/OFF operation.
    Engineer’s note

    The function letters are not a universal standard used by all manufacturers. Before commissioning the system, the operating diagram of the selected A / b / C / d / E / F / G / H / L / n mode must be checked.

    LCD display and control

    • selected operating mode;
    • configured time;
    • elapsed or remaining time;
    • seconds, minutes or hours;
    • timing status.

    The relay output status is additionally indicated by an LED indicator.

    SET and ADJ buttons

    SET
    • confirms the function;
    • confirms the time parameter;
    • moves to the next setup stage.
    ADJ
    • changes the selected function;
    • changes the time value;
    • selects other setup parameters.

    Time range

    The time can be set from 0.1 seconds to 999 hours.

    S
    Seconds
    M
    Minutes
    H
    Hours
    5A contact – load type must be considered

    The specified 5A / 250V AC contact rating applies to a resistive load.

    Motors, transformers, solenoids, LED power supplies, pumps, compressors and other reactive loads may have significantly higher starting currents.

    In such cases, use the relay in the control circuit and switch the main load through a correctly selected contactor or intermediate relay.

    Technical data

    Type Digital multifunction timer relay
    Operating functions 10
    Modes A, b, C, d, E, F, G, H, L, n
    Time range 0.1 s–999 h
    Supply A1–A2 230V AC
    Frequency 50/60Hz
    Alternative supply A2–A3 24V AC/DC
    T input 24–240V
    Power consumption <6VA
    Output 1 changeover relay contact
    Contact rating 5A / 250V AC, resistive load
    Display LCD
    Controls SET / ADJ
    Operating temperature −20…+55°C
    Max. conductor cross-section 2.5mm²
    Protection rating IP20
    Mounting 35mm DIN rail
    Width approx. 17.5mm / 1 module
    Dimensions approx. 90 × 17.5 × 70.7mm
    Weight <100g

    Advantages

    • 10 operating functions in one device – one model covers many typical timer control functions.
    • Wide 0.1 s–999 h range – suitable for both short pulses and long delays.
    • LCD display – settings and time can be viewed directly.
    • Digital adjustment – more accurate and repeatable than an analogue potentiometer.
    • Cyclic ON/OFF modes – separate ON and OFF times can be configured.
    • External T control input – allows integration into sensor, PLC or other control system circuits.
    • 230V AC supply via A1–A2 or alternative 24V AC/DC supply via A2–A3.
    • 50/60Hz operating frequency when using AC supply.
    • Only 1 DIN module wide – saves space in an electrical or automation cabinet.

    Disadvantages / limitations

    • The 5A contact rating applies to a resistive load – motors and other loads with high starting current will often require a contactor.
    • Only one changeover relay contact – more complex circuits may require additional intermediate relays.
    • The T input is not a dry contact input – the control signal type and voltage must be checked.
    • 10 functions require correct mode selection – if the wrong mode is selected, the device will operate differently from expected.
    • No weekly or calendar programming – this is a functional timer relay, not a weekly programmable timer.
    • No RS485, Modbus, Wi-Fi or Ethernet communication.
    • IP20 – intended for installation inside a protected electrical or automation cabinet.

    Suitable for

    • electricians and automation installers;
    • contactor control circuits;
    • ventilation automation;
    • pump and compressor control through a contactor;
    • production line timing sequences;
    • conveyor and dosing systems;
    • lighting automation;
    • periodically operating equipment;
    • PLC- and sensor-controlled circuits.

    Not suitable for

    • Direct switching of high-power motors or other loads with high starting current.
    • Systems requiring a weekly or calendar schedule.
    • Systems requiring Modbus, RS485, Wi-Fi or remote control.
    • Open installation in damp or dusty environments without an additional enclosure.

    Practical example – fan after 30 seconds

    The fan contactor must switch on 30 seconds after the system starts.

    1. Select mode A.
    2. Set the time to 30.0 s.
    3. Switch on the power supply.
    4. The LCD display starts counting the time.
    5. After 30 seconds, the relay output switches.
    6. The output controls the fan contactor coil.

    Practical example – cyclic ON/OFF

    If the device must operate ON for 50 s and OFF for 2 s, mode L can be used.

    Set: tON = 50 s and tOFF = 2 s. The relay automatically repeats the ON/OFF cycle.

    Quick selection guide

    Simple ON-delay required SUITABLE, although a simpler relay may also be selected
    Several different timing functions required YES
    Cyclic ON/OFF operation required YES
    External trigger signal required YES – T input
    Time setting up to 999 h required YES
    230V AC supply required YES – A1/A2
    24V AC/DC supply required YES – A2/A3
    Weekly schedule required NO
    Direct control of a high-power motor required NO – use a contactor

    Installation and commissioning sequence

    1. Disconnect power from the relevant circuits.
    2. Check which relay supply option will be used: 230V AC via A1–A2 or 24V AC/DC via A2–A3.
    3. Mount the relay on a 35mm DIN rail.
    4. Check the terminal diagram on the housing of the specific device.
    5. Connect the selected power supply.
    6. If used, connect the T control input.
    7. Connect the relay output to the control circuit.
    8. Select the required operating mode.
    9. Set the required time or ON/OFF times.
    10. Test the first cycle without the main power load.
    11. Check the operation of the relay output and T input.
    12. Only after testing, start the controlled equipment.

    Frequently asked questions

    Is this only an ON-delay relay?

    No. It has 10 different operating functions.

    What is the maximum configurable time?

    Up to 999 hours.

    Can separate ON and OFF times be configured?

    Yes. Separate ON and OFF intervals can be configured in cyclic modes.

    What is the main relay supply voltage?

    230V AC, connected via terminals A1–A2. Frequency – 50/60Hz.

    Can the relay operate from 24V?

    Yes. Alternative 24V AC/DC supply is connected via terminals A2–A3.

    What is the T input used for?

    It is an external trigger or control signal input used in some of the relay operating modes.

    Can the relay be controlled by a sensor or PLC?

    Yes, provided that its output signal is electrically compatible with the T input.

    Can a 5A motor be connected directly?

    This cannot be determined from the 5A nominal contact rating alone. For motors, the use of a contactor is recommended.

    Installer’s note

    This is a multifunction timer relay, so correct wiring is only one part of the setup. It is equally important to select the correct operating mode, time parameters and appropriate supply terminal pair. When using 230V AC supply, terminals A1–A2 are used; when using 24V AC/DC, terminals A2–A3 are used. A complete test cycle is recommended before connecting the final load.

    Digital multifunction timer relay designed for electrical and automation control systems. 10 operating functions, 0.1 s–999 h range, LCD display, external T input, 5A changeover contact and DIN mounting allow it to be used for ON-delay, OFF-delay, pulse and cyclic control. The relay can be powered by 230V AC via A1–A2 or alternatively by 24V AC/DC via A2–A3 terminals.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Modular photo relay | twilight switch with external sensor | 16 A | 12–240 V AC/DC | 1–50 000 lx | 1CO | DIN | GanzKK | SOU-1/UNI
    Code: SOU-1/UNI

    DIN rail twilight switch with universal 12–240 V AC/DC supply and external sensor: 1–50,000 lx, 1CO 16 A AC1, 0–2 min delay, 1 module.

    Price 42.47 € VAT incl.
    ( 35.10 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information