Modular digital automatic phase selector relay | voltage and unbalance monitoring | 3-phase to 1-phase | 63A | 230V | DIN | ELATOVPD3-63VA
Code: ELATOVPD3-63VAPrice 137.94 € VAT incl.( 114.00 € VAT excl. )Automatic phase selector for a single-phase 230 V load from a 3P+N network: up to 63 A, voltage, unbalance and 1–63 A current monitoring, L1/L2/L3 voltage display, ≈5 DIN modules.
-
Modular digital automatic phase selector relay | voltage and unbalance monitoring | 3-phase to 1-phase | 63A | 230V | DIN | ELATOVPD3-63VA
ELATOVPD3-63VA is an automatic phase selector that supplies a single-phase 230 V load from a three-phase 3P+N network. The relay continuously measures the L1, L2 and L3 voltages and connects the single-phase output to the phase whose parameters are within the set limits. It is intended for panels with a three-phase supply where the critical equipment is single-phase.
Key point:
A standard voltage relay simply disconnects the load when a phase fails. This relay also transfers the load to another healthy phase, so the boiler, pump or security system is powered again after a short interruption, as long as at least one phase is normal. The display shows all three phase voltages and the load current, so a network problem can be assessed immediately without test instruments.Input
3P+N, 220–230 V phase–NOutput
1 phase + N, up to 63 AMonitoring
overvoltage, undervoltage, unbalance, current 1–63 ADisplay
L1 / L2 / L3 (V) + current (A), active phase LEDOperating principle
The relay mounts on a 35 mm DIN rail and takes about 5 modules. The housing has 4 terminals on top and 2 at the bottom: the input is three phases and neutral, the output is one phase and neutral for single-phase circuits. Connect only according to the manufacturer's wiring diagram supplied with the device.
The controller continuously measures the voltage of all three phases (±1 % accuracy) and compares it with the set upper and lower limits. The output is fed by one selected phase – indicated by the L1, L2 or L3 LED. If the active phase voltage goes out of limits, the phase is lost or the phase unbalance exceeds the set value (trip delay 10 s), the load is disconnected and, if another healthy phase is available, transferred to it.
Result: the single-phase load is supplied from the best phase at that moment, and when all phases are out of limits it stays disconnected and protected against over- and undervoltage. In addition, the relay measures the load current and disconnects the output when the set current limit (1–63 A) is exceeded.
Why choose ELATOVPD3-63VA?
One modular device replaces a voltage relay, a phase monitoring relay and a manual phase selector switch for a single-phase circuit. When one phase fails, there is no need to wait for an electrician – the critical circuit automatically moves to a healthy phase.Display information
The front panel has 4 digital LED displays, so the network status can be seen at a glance – without opening the panel or using test instruments.
L1
L1 phase voltage, VL2
L2 phase voltage, VL3
L3 phase voltage, VA
Load current, AIndication and controls:- LEDs L1, L2, L3 show which phase is currently supplying the single-phase output
- The Fault LED shows that a fault has been detected
- Buttons power on/off, SET, ▲ and ▼ are used for operation and parameter setting
- The display shows immediately which phase voltage has deviated and how much current the load draws
How does it differ from a standard voltage monitoring relay?
A standard voltage monitoring relay only disconnects the load when the voltage goes out of limits, and the equipment stays unpowered until the network recovers. ELATOVPD3-63VA disconnects the load and automatically transfers it to another healthy phase.
Function Standard voltage relay ELATOVPD3-63VA Monitors network voltage Yes Yes – L1, L2 and L3 separately Disconnects the load when voltage is out of limits Yes Yes Transfers the load to another phase No Yes, if a healthy phase is available Shows all phase voltages Depends on the model Yes, in volts Shows load current Depends on the model Yes, in amperes Adjustable current limit Depends on the model 1–63 A Important:
Phase switchover causes a short power interruption, and the output is always single-phase 230 V – the relay does not convert voltage and does not replace a UPS or ATS.Technical specifications
Product type Automatic phase selector relay (3-phase to 1-phase) with voltage, unbalance and current monitoring Manufacturer Elsp Group Code ELATOVPD3-63VA Input 3P+N (L1, L2, L3, N) Rated voltage 220–230 V AC phase–neutral Operating voltage range 140–300 V AC Frequency 50/60 Hz Output 1 phase + N, 230 V AC; 1 NO contact Maximum load current 63 A Current protection setting 1–63 A, adjustable Protection functions Overvoltage and undervoltage (adjustable limits), phase unbalance, load current Hysteresis 5 V – overvoltage and unbalance, 3 V – undervoltage Unbalance trip delay 10 s Voltage measurement accuracy ±1 % Display 4 digital LED displays: L1, L2, L3 voltage (V) and load current (A) Indication LED: Fault, L1, L2, L3 (active phase) Controls Buttons: on / off, SET, ▲, ▼ Insulation voltage 450 V Switching life 100,000 cycles (electrical and mechanical, per manufacturer data; actual life depends on the load) Protection degree IP20 Dimensions 90 × 91 × 50 mm (≈ 5 DIN modules) Mounting 35 mm DIN rail Operating environment Relative humidity < 50 % at 40 °C (non-condensing), altitude up to 2000 m, pollution degree 3 Main functions
- Automatic phase selection – the single-phase load is transferred to a healthy phase without human intervention.
- Over- and undervoltage monitoring – equipment is disconnected while the voltage is outside the set limits.
- Phase unbalance monitoring – responds to voltage unbalance caused by a broken neutral or uneven loading.
- Current limit 1–63 A – the output is disconnected if the load exceeds the set value.
- Three-phase voltage and current display – network condition is visible without a multimeter.
- Active phase and fault LEDs – you see at once which phase feeds the load and whether there is a fault.
- Automatic recovery – power is restored without manual reset once the voltage returns to normal.
Where is it used?
- Rural houses and farmsteads with frequent single-phase outages or voltage drops
- Supply of heating boilers and circulation pumps
- Single-phase water supply and drainage pumps
- Intruder alarms, video surveillance, communication equipment
- Refrigerators, freezers and single-phase refrigeration equipment
- Gate automation and building control circuits
- Small business premises with a three-phase supply and critical single-phase loads
Use by need
Homeowner or farmstead owner.
When one phase fails, the boiler and pumps are powered again after a short interruption – the relay moves them to another healthy phase by itself.Installing electrician.
One 5-module device instead of several relays and a selector switch, with clear phase diagnostics on the display.Security system installer.
If a phase fails, alarm and CCTV power is automatically restored from another phase, as long as at least one normal phase is available on site.Practical application
If one phase frequently drops out at a farmstead and the gas boiler and circulation pump are connected to exactly that phase, install ELATOVPD3-63VA in the panel: the boiler and pump circuit is connected to the relay output, and when the active phase fails the load is briefly disconnected and the relay transfers the supply to another healthy phase – heating resumes automatically, and the display shows which phase has failed.Pros
- Automatic transfer of a single-phase load between L1, L2 and L3
- Overvoltage, undervoltage, unbalance and current monitoring in one device
- All three phase voltages and the current shown at the same time
- Adjustable current limit 1–63 A
- Wide operating range 140–300 V AC
- Compact – about 5 DIN modules
Cons / limitations
- Single-phase output only – not suitable for three-phase motors and 3 × 400 V equipment
- Not short-circuit protection – a circuit breaker upstream of the relay is mandatory
- 63 A is the total output current; for motors and compressors with high inrush currents keep a margin or switch via a contactor
- A short interruption occurs during phase transfer – this is not a UPS
- Does not transfer between two different sources (grid / generator) – use an ATS for that
Safety and installation notes
- Installation, wiring and limit setting must be done by a qualified electrician with all phases isolated
- Wire only according to the manufacturer's wiring diagram; before energising, check the input (L1, L2, L3, N) and output (L, N) terminals
- Install a circuit breaker rated no more than 63 A upstream of the relay; protect the output circuits with standard overcurrent and residual current protection as required by installation rules
- Select the cable cross-section according to the actual current and the rating of the protective device
- The device is IP20 – for dry, enclosed distribution boards only
- Do not connect loads that require several phases or a specific phase sequence to the output
Quick selection guide
3P+N → 1F63 A1–63 A current limit140–300 V ACIP20DIN | ≈ 5 modulesSuitable when you need to:- supply a critical single-phase load from the most reliable phase of a three-phase network
- protect equipment against over- and undervoltage
- see all phase voltages on the front of the panel
Check before use:- that the site has a 3P+N network with neutral
- that the total load current does not exceed 63 A (with a margin for inrush currents)
- that there are about 5 free modules in the panel
- that the set voltage limits match the requirements of the connected equipment
Important reminder: the relay does not replace a circuit breaker, an RCD or a UPS – it selects the phase and disconnects the load, but provides neither short-circuit protection nor uninterrupted power.FAQ
Can it supply a three-phase motor?
No – the relay output is single-phase 230 V only.Is the transfer between phases uninterrupted?
No – there is a short interruption during transfer, so sensitive IT equipment also needs a UPS.Does the relay replace a circuit breaker?
No – a circuit breaker up to 63 A must be installed upstream, as the relay does not interrupt short-circuit currents.Does 63 A apply to each phase?
No – 63 A is the maximum total current of the single-phase output.Can it switch between the grid and a generator?
No – the relay selects a phase from one 3P+N network only; two sources require an ATS.How much panel space does it take?
About 5 DIN modules – the housing measures 90 × 91 × 50 mm.Modular digital automatic phase selector relay | voltage and unbalance monitoring | 3-phase to 1-phase | 63A | 230V | DIN | ELATOVPD3-63VA
The ELATOVPD3-63VA automatic phase selector relay supplies a single-phase load of up to 63 A from a healthy phase of a three-phase 3P+N network protects it against overvoltage, undervoltage and phase unbalance, and disconnects it when the set current limit is exceeded. It suits panels in houses, farmsteads and small premises where critical single-phase equipment must keep running even when one phase fails.
Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products