Modular multifunction time relay | timer | 10 functions | 0.1s-30h | 230VAC/24VAC/DC | DIN
Code: ES-ERX-10Price 25.26 € VAT incl.( 20.88 € VAT excl. )Buy more, pay less10+ pcs. – 19.42 € for pcs. -23%Want another price? Suggest yours!Multi-function modular time relay designed for switching, delay, pulse, and cyclic control of electrical and automation circuits. Features 10 selectable operating functions and a wide adjustable time range from 0.1 seconds to 30 hours. Supports 150–260 V AC or 24 V AC/DC supply voltage, has 1 SPDT changeover contact, and LED status indication. Designed for mounting on a standard 35 mm DIN rail in electrical distribution and automation panels.
-
Multifunction Time Relay | 0.1s-30h | 230VAC / 24VAC/DC | DIN Multifunction Time Relay | 0.1s-30h | 230V AC / 24V AC/DC | 10 Functions
Multifunction time relay – a universal automation control device designed for controlling switching ON, switching OFF, pulses and other timing functions in electrical circuits. The relay has 10 selectable operating functions and an exceptionally wide time setting range from 0.1 seconds to 30 hours. The device can be powered by 150-260V AC or 24V AC/DC, features one 1-SPDT changeover relay contact, LED status indication and is designed for mounting on a standard 35mm DIN rail.
10 time-control functions in one deviceThe relay allows selection of ON delay, OFF delay, control-signal-triggered ON or OFF delay, single pulses, cyclic operation and other timing functions. The maximum time is selected with a separate range selector, while the precise value is set using the 0.1-1.0 multiplier. The total adjustable time range is from 0.1 seconds to 30 hours.
0.1s – 30hTime range10Operating functions230V / 24VPower supply options1-SPDTChangeover contactOperating principle and functions
Function Mode Operating principle 1 ON Delay When power is applied, the preset time starts counting. When the time expires, the relay output is activated and remains active until the power supply is disconnected. 2 OFF Delay When power is applied, the relay is activated immediately. The time countdown begins, and when it expires, the relay is deactivated. 3 Control Signal ON Delay When the T control signal is received, the preset time starts counting. When the time expires, the relay is activated. If the control signal disappears during the delay period, the time countdown is interrupted and reset. 4 Control Signal OFF Delay When the T signal is received, the relay is activated. When the signal disappears, the delay countdown begins, and when it expires, the relay is deactivated. 5 Single Pulse with Control Signal When the T signal is received, the relay is activated for the preset time. A change in the control signal during the time countdown does not interrupt it. 6 Single Pulse After Signal When the T signal is received, the relay waits for the signal to switch off. When the signal disappears, the relay is activated for the preset time and then automatically deactivated. 7 ON and OFF Delay with Control When the T signal switches on, the ON delay begins, and when it switches off, the OFF delay begins. If the signal changes during the delay, the time countdown may be interrupted and reset. 8 Pulse Output with Control When the T signal is received, the relay is activated for the preset time and then switches off. A repeated signal allows a new pulse to be initiated according to the operating logic of the selected mode. 9 Cyclic Timer, Start ON When power is applied, the relay is activated and periodically switches between ON and OFF states according to the preset time. The cycle repeats for as long as the device is powered. 10 Cyclic Timer with Control The relay cyclically switches between ON and OFF states, while the T control input allows the cyclic operating process to be controlled or stopped. Time setting
The time value is set using two controls. The maximum-time selector is used to choose the main range, while the time multiplier control is used to set a value from 0.1 to 1.0.
Time calculation principleFinal time = selected maximum time (tm) × time multiplier (Xn). For example, when the 30-minute range and a multiplier of 0.5 are selected, the operating time will be 15 minutes.
Selected range Adjustment range 1s 0.1 – 1s 5s 0.5 – 5s 10s 1 – 10s 30s 3 – 30s 60s 6 – 60s 10min 1 – 10min 30min 3 – 30min 60min 6 – 60min 10h 1 – 10h 30h 3 – 30h How to set the relay?
- Before switching on the power supply, select the required operating function using the function selector.
- Use the maximum-time selector to choose the required range from 1 second to 30 hours.
- Use the time multiplier control to select a value from 0.1 to 1.0.
- Calculate the actual time by multiplying the maximum value of the selected range by the selected multiplier.
- Connect the device according to the electrical wiring diagram and only then switch on the power supply.
Important when changing the functionIt is recommended to select the operating function while the device is switched off. If the function is changed while the power supply is on, wait at least approximately 0.3 seconds before switching it on again. Otherwise, the newly selected function may not be recognised.
LED indication
Indicator Purpose Relay LED Indicates the state of the relay output contacts. T LED Indicates the state of the T control signal. M LED Indicates the time-counting state and the operating state of the selected function. Power LED Indicates the power supply status of the device. Relay contact states
Relay state Contact state Relay activated Contacts 1 and 2 are open, contacts 2 and 3 are connected. Relay LED is illuminated. Relay deactivated Contacts 1 and 2 are connected, contacts 2 and 3 are open. Relay LED is not illuminated. Technical specification
Device type Multifunction time relay Power supply for 230V version 150 – 260V AC (A1-A2) Alternative power supply 24V AC/DC (A2-A3) Operating frequency 50/60Hz (AC) Power consumption <4VA Time range 0.1 seconds – 30 hours Number of operating functions 10 Reset Electrical reset Indication Relay, T, M and Power LED indicators Relay output 1-SPDT (1 changeover contact) Contact load 5A / 250V AC (resistive load) Electrical endurance at rated AC1 load 1x105 cycles Protection rating IP20 Operating temperature -20°C ~ +55°C Mounting 35mm DIN rail Connection Terminal connection Cable cross-section 0.22mm² – 1.5mm² Operating altitude <2000m above sea level Weight <80g Advantages / benefits
- 10 different time-control functions in one device.
- Very wide time setting range from 0.1 seconds to 30 hours.
- Separate time-range and 0.1-1.0 multiplier adjustment allows more precise selection of the required time.
- 150-260V AC or 24V AC/DC power supply options.
- The T control input provides additional pulse and signal-controlled delay functions.
- The 1-SPDT changeover contact allows both NO and NC control logic to be used.
- LED indicators show the power supply, control signal, time-counting and relay output states.
- Low power consumption – less than 4VA.
- Compact DIN rail mounting in automation and electrical control panels.
Disadvantages / limitations
- Function selection: it is recommended to change the operating function only when the device power supply is switched off.
- Limited relay contact load: the output contact is rated for up to 5A / 250V AC resistive load, therefore a contactor or interface relay must be used for higher loads.
- IP20 protection: the device is intended for installation inside an enclosed electrical or automation panel and must not be directly exposed to moisture.
- Mechanical adjustment: functions and time are set using adjustment knobs, therefore remote digital parameter programming is not available.
What is it suitable for? (Applications)
- Electrical and automation control panels
- Start-up or shutdown delay for motors, pumps and fans
- Lighting control systems
- Heating and ventilation automation
- Cyclic control of production equipment
- Generating pulse control signals
- Control of contactors and interface relays
- Industrial, commercial and residential building automation systems
What is it not suitable for?
- Direct switching of high-power electrical loads
- Open installation in damp or wet locations
- Systems requiring remote digital time programming
- Processes requiring a single timing interval longer than 30 hours
Practical example
In a ventilation system, the fan must switch on only 15 minutes after receiving a start command. The ON Delay function is selected on the relay, the maximum-time selector is set to the 30-minute range, and the multiplier is set to 0.5. This results in a 15-minute delay. When the control circuit is activated, the relay begins counting the time, and after 15 minutes it activates the output contact, which can switch on the fan contactor.
Frequently asked questions (FAQ)
What is the relay's time setting range?The time can be set from 0.1 seconds to 30 hours by selecting the appropriate time range and a 0.1-1.0 multiplier.
How many operating functions does the relay have?The relay has 10 different operating functions, including ON and OFF delays, control-signal-triggered functions, pulse modes and cyclic modes.
What is the relay supply voltage?Using terminals A1-A2, the relay operates within the 150-260V AC range. Using terminals A2-A3, a 24V AC/DC power supply can be used.
How is the set time calculated?The selected maximum time range is multiplied by the 0.1-1.0 time multiplier. For example, 30min × 0.5 = 15min.
Does the relay have a cyclic operating function?Yes. The 10 operating modes include cyclic functions in which the relay output is periodically switched ON and OFF according to the preset time.
Can the relay be used with a contactor?Yes. The relay's 1-SPDT output contact can be used to energise a contactor coil or another automation control circuit.
What is the maximum relay contact load?The relay contact is rated for up to 5A / 250V AC resistive load. For higher loads, a suitable contactor or other power switching equipment must be used.
Important safety note for the installerUse the device according to its intended purpose and wiring diagram. Do not use it in a damp environment. Provide a suitable switch and automatic circuit breaker in the installation circuit. They must be installed near the device, in a location easily accessible to the operator, and marked as electrical circuit disconnecting devices. It is recommended to change the operating function and main settings only after disconnecting the device from the power supply.
MaintenanceBefore performing maintenance or cleaning, switch off the power supply and disconnect the device from the electrical circuit. Clean the housing with a soft, dry cloth. Do not use conductive materials, aggressive chemical cleaners or solvents that may damage the device. After cleaning, make sure that the relay operates correctly.
Multifunction time relay – a universal solution for electrical and automation systems requiring adjustable delays from 0.1 seconds to 30 hours, pulse or cyclic control functions and compact DIN rail mounting.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products