Modular single-phase energy meter | 5(45) A | 230 V | DIN | OLLO 1P-201D
Code: 1P-201DPrice 19.99 € VAT incl.( 16.52 € VAT excl. )Modular single-phase energy meter OLLO 1P-201D: direct connection, current 5(45) A, 230 V.
-
Modular single-phase energy meter | 5(45) A | 230 V | DIN | OLLO 1P-201D
1P-201D is a modular single-phase energy meter by OLLO for metering active energy (kWh) in single-phase 230 V circuits. It is connected directly, current up to 45 A.
Key point:
When you simply need to know how much a specific circuit or room consumes, 1P-201D shows accumulated kWh without any configuration.Current
5(45) AVoltage
230 VMetering
check meteringMounting
DIN railOperating principle
The meter is mounted on a 35 mm DIN rail and connected directly into the phase and neutral circuit – the full load current (up to 45 A) flows through the meter terminals.
The electronic measuring circuit continuously measures voltage and current, calculates active energy and accumulates it in kWh.
Accumulated kWh are stored in non-volatile memory – readings are not lost when voltage drops out.
Why choose 1P-201D?
Simple, reliable check metering at a low price.Technical specifications
Product type Modular single-phase energy meter Manufacturer OLLO Model / code 1P-201D Phases 1 phase (L + N) Rated voltage 230 V Current Ib (Imax) 5(45) A Frequency 50 Hz Connection direct (no current transformers) MID approval no Tariffs 1 tariff Pulse output no Communication interface no Mounting 35 mm DIN rail Country of origin China Main functions
- kWh metering – you see the real consumption of a circuit or site.
- Data retention – accumulated kWh are not lost when voltage drops out.
Where is it used?
- Flat and house distribution boards
- Rented premises and sub-consumers
- Heater, water heater and heat pump circuits
- Country houses, garages, workshops
- 230 V AC side of solar power plants
- Temporary construction sites
Use by need
For home owners.
Finds out how much heating, a water heater or a workshop consumes.For electricians.
Quickly adds check metering to an existing panel.For farm owners.
Monitors costs of buildings or equipment separately.Practical application
If you rent out part of a flat or country house, 1P-201D is installed in the panel before that part's circuit breakers – every month you clearly see how many kWh the tenant used.Pros
- Simple check metering
- Direct connection up to 45 A
- Readings retained during power failure
Cons / limitations
- No MID approval – not suitable for commercial billing
- No communication interface – readings taken from the display
- Maximum current 45 A – larger loads need a meter with current transformers
- Single-phase circuits only
Safety and installation notes
- Installation by a qualified electrician with voltage disconnected
- Install a circuit breaker before the meter according to the cable cross-section
- Follow the terminal marking (L in / L out / N)
- Tighten terminals to the correct torque – a loose contact overheats
- Do not exceed 45 A current
- The meter does not protect against overload or short circuit
Quick selection guide
1 phase5(45) A230 Vno MIDno communicationDIN railSuitable when you need:- check metering of consumption
- a simple solution without configuration
- direct connection up to 45 A
Check before use:- the circuit is single-phase 230 V
- the maximum current does not exceed 45 A
- there is space in the panel
Important reminder: without MID approval the meter is intended for check metering, not for billing with the energy supplier or tenants.FAQ
Can it be used for billing a tenant?
No, the meter has no MID approval – choose a MID meter for that.What is the maximum current?
Direct connection – up to 45 A.Are current transformers needed?
No, the meter is connected directly.Are readings lost during a power failure?
No, accumulated kWh are stored in memory.Can it be read remotely?
No, readings are shown on the display only.How is it mounted?
On a 35 mm DIN rail in a panel.Modular single-phase energy meter | 5(45) A | 230 V | DIN | OLLO 1P-201D
1P-201D is a modular single-phase energy meter 45 A for direct connection. Suitable for check metering of circuits and premises.
Published: 2026-11-24 · Data verified against the supplier's specification: 2026-11-24
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.Operating voltage230 V ACThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products