Products catalog

  • Modular three-phase energy meter | 100 A | 3×230/400 V | 1 tariff | S0 pulse output | MID | DIN | VEXEN ESM3100D

    Code: ESM3100D

    A basic three-phase active energy meter for direct connection up to 100 A, MID certified. It shows consumed energy in kWh and has a 1000 imp/kWh pulse output for external logging.

  • Modular three-phase energy meter | 100 A | 3×230/400 V | 1 tariff | S0 pulse output | MID | DIN | VEXEN ESM3100D

    The VEXEN ESM3100D is a modular three-phase energy meter for direct connection in 4-wire 3×230/400 V networks up to 100 A. It is designed for active energy metering in distribution boards: apartments, houses, commercial premises and individual sub-circuits.

    Key point:
    This is the simplest model of the VEXEN three-phase line: one tariff, a kWh register and an S0 pulse output. It is MID certified (EU-type examination certificate 0120/SGS0432), so it is also suitable for billing between landlord and tenant. If you do not need remote reading via Modbus or network parameter analysis, it is the most rational choice.
    Max. current
    100 A
    Accuracy
    Class B (MID)
    Pulses
    1000 imp/kWh
    Width
    72 mm DIN
    ℹ
    Bidirectional metering
    For the basic ESM3100D version the manufacturer specifies active energy (kWh) metering only; separate import and export registers are described only for the DBi version. If consumed and exported energy must be seen separately, choose the ESM3100DM (RS485 Modbus, import / export).

    Communication interfaces and integration

    S0 pulse output
    1000 imp/kWh – pulses are sent to a PLC, data logger, BMS or smart home controller with a pulse input. This allows remote consumption counting without a digital bus.
    No digital interface
    This model has no RS485 Modbus or M-Bus. If you need to read values over a bus, choose the ESM3100DM (Modbus) or ESM3100DMB (M-Bus).

    Operating principle

    The meter is mounted on a 35 mm DIN rail and connected directly to 3 phases and neutral (L1, L2, L3, N) – no current transformers are needed up to 100 A.

    The electronic measuring circuit counts active energy in all three phases; the test LED and the pulse output give 1000 pulses per 1 kWh.

    Total energy is shown on a white backlit LCD, and the pulse signal can be passed to an external metering or control system.

    Why choose the VEXEN ESM3100D?
    It handles the most common task – counting a three-phase consumer's kWh reliably and legally (MID) without extra configuration. The compact 72 mm housing fits a standard modular board, and the S0 output lets you add simple remote metering later.

    Technical specifications

    Product type Modular three-phase active energy meter
    Manufacturer / model VEXEN ESM3100D
    Connection Direct, 3 phases + N (4-wire)
    Rated voltage 3×230/400 V AC
    Operating voltage range 80–120 % Un
    Basic current (Ib) 10 A
    Maximum current (Imax) 100 A
    Starting current / operating range 0.4 % Ib – Imax
    Short-time overcurrent 30 Imax / 0.01 s
    Frequency 50 Hz ±10 %
    Accuracy class B to EN 50470-3; 1 to IEC 62053-21
    MID Yes (certificate 0120/SGS0432)
    Tariffs 1
    Measured values Active energy (kWh)
    Communication interface None (pulse output only)
    Pulse output S0, 1000 imp/kWh
    Display LCD with white backlight
    Dimensions (H × W × D) 100 × 72 × 66 mm
    Mounting 35 mm DIN rail, 4 modules
    Protection degree IP51 (per manufacturer's manual)
    Insulation class II
    Operating temperature −25…+55 °C
    Storage temperature −40…+70 °C
    Relative humidity ≤ 90 %
    Power consumption ≤ 2 W / 10 VA per phase
    Standards EN 50470-1, EN 50470-3, IEC 62053-21, 2014/32/EU

    Main functions

    • Direct connection up to 100 A – no current transformers and no cost of installing them.
    • MID certificate – readings can be used for billing between parties (rental, sub-metering).
    • Class B / class 1 – accuracy to EN 50470-3 and IEC 62053-21.
    • S0 pulse output 1000 imp/kWh – simple integration into a PLC, BMS or data logger.
    • Backlit LCD – easy to read in a dark enclosure.
    • 72 mm DIN housing – takes 4 modules and fits a standard board.

    How does it differ from similar models?

    VEXEN ESM3100DM Has RS485 Modbus RTU and separate import / export metering; the ESM3100D offers kWh and a pulse output only.
    VEXEN ESM3100DM2T Multifunction (V, A, kW, kVAr, PF, THD), 2 tariffs and Modbus; the ESM3100D is a basic single-tariff kWh meter.
    Ollo 3P-351 / ESTXM302 Also simple 100 A modular meters without interfaces; the ESM3100D stands out with its MID certificate.
    THORGEON 01007 80 A, 2 tariffs, RS485 Modbus, MID; the ESM3100D has a higher 100 A limit but 1 tariff and no Modbus.

    Where is it used?

    • Check metering of three-phase supplies in apartments and houses
    • Rented premises and sub-tenant metering
    • Commercial premises, offices, shops
    • Workshops and small production halls
    • Metering of heat pumps, boilers and other three-phase loads
    • EV charging points (kWh metering)
    • Temporary construction site boards
    • Agricultural buildings and warehouses

    Use by need

    Landlords.
    MID readings allow electricity to be recharged to tenants on a sound basis.
    Electricians.
    Fast direct installation without CTs or extra configuration.
    Facility managers.
    S0 pulses are an easy way to feed data into an existing system.

    Practical application

    If a three-phase tenant circuit up to 100 A in an apartment block basement or business centre must be metered separately and billed periodically, the ESM3100D is installed in the board after the tenant's protective device, and readings are taken from the display or pulses are passed to the building's data logger.

    Pros

    • MID certificate and class B to EN 50470-3
    • Direct connection up to 100 A
    • S0 pulse output 1000 imp/kWh
    • Backlit LCD display
    • Compact 4-module DIN housing
    • Wide operating temperature range −25…+55 °C

    Cons / limitations

    • No RS485 Modbus or M-Bus – for remote digital reading choose the ESM3100DM or ESM3100DMB
    • Only 1 tariff – for dual-tariff metering choose the ESM3100DM2T
    • Does not measure voltage, current or power factor – the ESM3100DM2T does
    • The manufacturer does not specify separate import / export metering for this version – the ESM3100DM has it
    • Currents above 100 A require a CT meter (ES3100DCT)

    Safety and installation notes

    • Installation and wiring must be done by a qualified electrician with the circuit isolated and verified dead.
    • Install an upstream protective device (MCB or fuses) sized to the cable cross-section and load – the meter is not a protective device.
    • Follow the phase and neutral wiring diagram in the manufacturer's manual; swapped inputs and outputs distort the readings.
    • Tighten the power terminals to the specified torque – a loose contact at 100 A overheats and can damage the meter.
    • Do not break the seals or open the front cover – this affects the measurement and, according to the manufacturer's manual, voids the warranty.

    Quick selection guide

    100 A direct
    MID class B
    1 tariff
    S0 1000 imp/kWh
    Suitable when you need:
    • legal (MID) three-phase kWh metering up to 100 A
    • a simple meter with no configuration
    • a pulse signal to a PLC or data logger
    Check before use:
    • that the circuit current does not exceed 100 A
    • that the network is 4-wire 3×230/400 V
    • that there is room for 4 modules in the board
    Important reminder: The meter only measures energy – it does not protect against overload, short circuit or residual current and does not replace the grid operator's billing meter without the operator's consent.

    FAQ

    Does the ESM3100D have Modbus?
    No – Modbus RTU is on the ESM3100DM; the ESM3100D has only an S0 pulse output.
    Is the meter MID certified?
    Yes, the manufacturer states MID certification (EU-type examination certificate 0120/SGS0432).
    What is the maximum current?
    The direct connection limit is 100 A, the basic current is 10 A.
    Does it measure energy exported to the grid?
    The manufacturer does not specify separate import / export metering for this version – choose the ESM3100DM for that.
    How many pulses per kWh?
    1000 imp/kWh for both the LED and the pulse output.
    How much space does it take?
    A 72 mm wide housing – 4 DIN modules.

    VEXEN ESM3100D – three-phase MID meter 100 A

    The VEXEN ESM3100D is a modular three-phase single-tariff meter for direct connection up to 100 A with MID certificate, class B and an S0 pulse output of 1000 imp/kWh.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals

    privacy policy

    Information