Copper installation cable NYM-J | 4×10 mm² | 300/500 V | white | 1 m | Lietkabelis KH05VV-U 4G10
Code: 92049001NYM-J 4×10 mm² (KH05VV-U 4G10) – AB Lietkabelis copper installation cable with solid class 1 conductors, PVC insulation and a white PVC sheath, 300/500 V. For fixed installation inside buildings: in walls, under plaster, in conduits and trunking. Sold by the metre.
4 cores (L1, L2, L3, PE) for three-phase 400 V loads without neutral – motors, pumps, compressors. If there will be single-phase loads, choose a 5-core cable.
-
Copper installation cable NYM-J | 4×10 mm² | 300/500 V | white | 1 m | Lietkabelis KH05VV-U 4G10
NYM-J 4×10 mm² – white copper cable with 4 solid conductors (L1, L2, L3, PE – no neutral N) for fixed electrical installation inside buildings. Manufacturer – AB Lietkabelis, designation KH05VV-U 4G10, rated voltage 300/500 V.
Key point:
A four-core cable is intended for three-phase loads that need no neutral: three phases and a protective PE. If single-phase appliances will also be supplied from the same circuit, choose 5-core NYM-J.Number of cores
4 (L1, L2, L3, PE)Cross-section
10 mm²Typical protection
40 A circuit breakerInstallation
IndoorsHow it works
The cable is installed permanently: in walls, under plaster, in conduits or trunking from the board to the load. Cores are connected by colour: L1, L2, L3, PE – no neutral N.
Solid 10 mm² copper conductors carry the current, while PVC insulation and the white sheath protect them mechanically and electrically. The continuous conductor temperature is up to +70 °C, so the current rating depends on how well the cable dissipates heat.
With the right protection (40 A) and length (up to ≈ 75 m at 40 A), the circuit runs for years without overheating and the voltage drop stays within 3 %.
Why choose NYM-J 4×10 mm²?
It is a simple, reliable solution for a circuit where three-phase 400 V without neutral is needed: solid conductors are easy to terminate, the white sheath looks neat on surfaces, and you buy exactly as many metres as you need.Technical data
Product type Copper installation cable NYM-J Manufacturer AB „Lietkabelis“ – KH05VV-U 4G10 Number of cores 4 (L1, L2, L3, PE – no neutral N) Cross-section per core 10 mm² Conductor Solid (class 1) annealed copper Insulation / sheath PVC / white PVC Rated voltage 300/500 V Conductor temperature Up to +70 °C continuous, up to +160 °C during a short circuit Ambient temperature In service −30…+70 °C, installation −5…+40 °C Minimum bending radius ≥ 5 × cable diameter Cable diameter (manufacturer data) 15.98 mm Current rating (indicative) about 46–57 A to IEC 60364-5-52 (3 loaded cores, +30 °C, installation methods B2–C) Typical protection 40 A circuit breaker – up to ~27.7 kW (three-phase 400 V without neutral, cos φ = 1) Circuit length (ΔU ≤ 3 %) up to ≈ 75 m at 40 A load Installation Indoors: in walls, under plaster, in conduits, trunking, surface-mounted Sales unit 1 metre ⚠ Check: values are indicative. Grouped cables, cables in thermal insulation or at higher temperatures have a lower rating. Protection follows IB ≤ In ≤ Iz; the final decision rests with the electrical design.Key functions
- Power transmission – three-phase 400 V without neutral up to ~27.7 kW with 40 A protection.
- Solid class 1 conductors – reliable contact in screw and push-in terminals.
- Colour-coded cores – L1, L2, L3, PE – no neutral N, faster and safer connection.
- PVC insulation and sheath – double protection for indoor installation.
- Sold by the metre – less waste and a more accurate estimate.
How does it differ from similar cables?
- NYM-J 4×6 mm² – smaller cross-section – about 34–41 A, for lighter loads or shorter runs.
- CYKY-L cable – black, also for outdoor and underground use with protection; NYM-J is for indoor use only.
Where is it used?
- Three-phase motors – machine tools, fans.
- Pumps and compressors – without neutral.
- Three-phase heaters – delta-connected.
- Plant rooms – where the cable runs indoors.
Use by need
Workshop owner.
Supply to a three-phase motor, pump or compressor without neutral.Automation installer.
Power lines from the board to three-phase drives indoors.Maintenance team.
Replacing existing three-phase load cables with the same type.Practical example
For example, a three-phase compressor motor that needs no neutral has to be connected in a workshop. NYM-J 4×10 mm² with 40 A protection is suitable if the motor current and starting conditions match the protection and the run is no longer than ≈ 75 m.
Pros
- Solid copper conductors – hold their shape and terminate reliably.
- White sheath – neat appearance for surface installation.
- Made by Lietkabelis – established Lithuanian manufacturer with clear technical data.
- Sold by the metre – pay only for the length you need.
Cons / limitations
- Not for direct burial or unprotected outdoor use – choose CYKY-L for that.
- Not for portable equipment – solid conductors are not made for repeated flexing.
- PVC insulation – where halogen-free cables are required, choose NHXMH-J.
- No neutral N – for single-phase loads choose a 5-core cable.
Safety and installation notes
- Before work, isolate the supply, secure it against switching on and verify that no voltage is present.
- Run cables in walls vertically and horizontally – so they aren't drilled later.
- Strip cores with a proper tool without nicking the copper.
- Before energising a new circuit, measuring insulation resistance is recommended.
- Installation must be carried out by a qualified electrician.
- 4×10 is not a single 40 mm² conductor.
- The cable is not chosen by the breaker alone – installation method and circuit length are checked too.
☝ Elsprendimai.eu recommends: NYM-J selection guide · CYKY-L cables for outdoors and undergroundQuick selection guide
Choose NYM-J 4×10 mm² for a three-phase 400 V load without neutral.
4 × 10 mm²300/500 V40 AIndoorsSuitable when you need:- a three-phase load without neutral;
- protection by a 40 A circuit breaker;
- a run of up to ≈ 75 m at 40 A load.
Check before ordering:- that the load and breaker match the 4×10 mm² cross-section;
- that the circuit is no longer than ≈ 75 m at 40 A load;
- that the cable will be installed indoors;
- that you order enough length for connection.
Important reminder: The 4×10 mm² designation alone does not define the maximum current or power. Choose the cable by load, installation method, circuit length and protective device.FAQ – frequently asked questions
What is the difference between NYM-J and KH05VV-U?
It is the same cable type: NYM-J is the common designation, KH05VV-U is the Lietkabelis product designation.Does 4×10 mean a total cross-section of 40 mm²?
No. These are 4 separate 10 mm² cores.Can it be laid outdoors or underground?
No. NYM-J is for indoor use; outdoors and underground choose CYKY-L, underground with mechanical protection and warning tape.Do you sell by the metre?
Yes, the sales unit is 1 metre; for project quantities we prepare a quotation.Which circuit breaker should I choose?
Usually 40 A; finally by load, installation method and circuit length (IB ≤ In ≤ Iz).Can it be installed under plaster?
Yes, NYM-J is intended for installation in walls, under plaster, in conduits and trunking indoors.Copper installation cable NYM-J | 4×10 mm² | 300/500 V | white | 1 m | Lietkabelis KH05VV-U 4G10
NYM-J 4×10 mm² (KH05VV-U 4G10) – white Lietkabelis copper cable with four solid conductors (L1, L2, L3, PE) for three-phase loads without neutral. Sold by the metre.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerSingle-core wires are also called monolithic wires,
while multi-core wires are flexible wires.Wires usually have a single conductor covered with an insulating layer.
Cables have several insulated wires, covered with a common sheath.
Conductor properties of wires:
The resistance of copper conductors is lower (0.017Ω) than that of aluminum (0.028Ω),
but copper has better conductivity.
Copper has better electrical and thermal conductivity than aluminum.
Copper wires are more flexible, more resistant to corrosion, and more durable.
Aluminum wires quickly oxidize upon contact with air, forming a film that weakens the contact.
Copper wires carry higher currents than aluminum wires.
Copper conductors are denser than aluminum. Therefore, copper wire is heavier.The cross-sectional area of wires is chosen according to the power of specific equipment,
for example: for a 1kW load, a 1.57 mm² cross-sectional area of the conductor is required.
For aluminum wires: 5A per 1mm², and for copper wires: 8A per 1mm².This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Price 48.40 € VAT incl.( 40.00 € VAT excl. )