    Panel meter guide: voltmeter, ammeter or multimeter – how to choose and connect

    Here – quick selection by situation, solution levels from a simple indicator to current monitoring with a relay, a matrix of all devices in the group, current measurement methods (shunt, ring current transformer, x/5 A), the most common mistakes and answers to practical questions. Specific parameters – in each product description.

    Colour meanings: ■ information · ■ benefit, solution · ■ ⚠ check · ■ ⚡ safety, mistakes

    What do you need? Quick selection

    Situation Solution Where to look
    Battery, solar or 12/24 V system – only the voltage needs to be seen Small DC voltmeter with 3-wire connection DC voltmeter 0–40 V, DC voltmeter 0–100 V
    DC system – both voltage and current need to be seen (charging, load) DC voltmeter-ammeter with shunt; supply the device with 4.5–30 V DC DC V/A 10 A, DC V/A 50 A, DC V/A 100 A
    230/400 V board – continuously see the mains voltage AC voltmeter 80–500 V, self-powered, 2 wires AC voltmeter 80–500 V
    Generator, inverter or UPS – voltage and frequency need to be seen AC voltmeter-frequency meter AC voltmeter + frequency
    Single-phase line – see the load current AC ammeter with ring current transformer AC ammeter 0–60 A
    Single-phase supply – voltage and current in one device AC voltmeter-ammeter with current transformer AC V/A 100–300 V / 100 A
    Power, energy (kWh) or cos φ need to be seen Multifunction AC multimeter multimeter V/A/W/kWh, multimeter V/A/W/VA/cos φ
    Board and industrial 68 × 68 mm format – voltage or current of one or all three phases DigiTOP voltmeter or ammeter 1-ph voltmeter, 3-ph voltmeter, 1-ph ammeter, 3-ph ammeter
    High current (50–800 A) and the load must be disconnected automatically via a contactor Ammeter with relay output and x/5 A transformer with CT 100/5 A, with CT 400/5 A, without CT

    Solution levels: from indicator to control

    Kibirkštis
    KibirkštisFirst decide what you want to get: just see a value, see several parameters, measure energy or respond automatically to an overload. The level depends on this – and so does the price.
    1Simple indicator

    One parameter: DC voltage, AC voltage or AC current.

    DC 0–40 V, DC 0–100 V, AC 80–500 V, AC 0–60 A

    2Two parameters in one

    Voltage + current or voltage + frequency.

    DC V/A 10 A, 50 A, 100 A, AC V/A, AC V/Hz

    3Power and energy

    Multifunction meter: W, kWh or VA and cos φ.

    V/A/W/kWh, V/A/W/VA/cos φ

    4Industrial format, 1 and 3 phases

    68 × 68 mm housing, monitoring of all phases.

    1-ph V, 3-ph V, 1-ph A, 3-ph A

    5Monitoring with relay

    Measures up to 800 A via an x/5 A CT and disconnects the load via a contactor.

    50 A, 100 A, 150 A, 200 A, 400 A, 600 A, 800 A, without CT

    AC or DC? The first question

    Fazė
    FazėYou cannot connect an AC device to a battery, nor a DC device to the 230 V mains. Look at the system, not the price: 230/400 V board, generator, inverter output – AC; battery, solar module side, 12/24/48 V – DC.
    Feature AC (alternating current) DC (direct current)
    Where 230/400 V boards, generators, UPS and inverter outputs Batteries, solar systems, campervans, boats, power supplies
    Typical voltages 80–500 V AC 0–100 V DC
    Device power supply Usually from the measured voltage DC V/A with shunt – separate 4.5–30 V DC
    Current measurement Ring or x/5 A transformer Shunt in the negative circuit

    How current is measured: shunt, ring CT or x/5 A

    Method How it works When to choose
    Shunt (DC) The entire load current flows through the shunt in the negative circuit; the device measures the millivolt drop (e.g. 75 mV at 50 or 100 A). For DC systems up to 100 A: 50 A, 100 A
    Ring CT (AC) The phase conductor is passed through the ring – there is no need to break the circuit. The transformer is matched to the specific device. For a single-phase line up to 60–100 A: ammeter, V/A, multimeter
    x/5 A CT (AC) Standard current transformer (e.g. 400/5 A); the ratio is set in the device. Suitable for high currents and busbars. For 50–800 A supplies and industry: ammeter with relay
    ⚠ Important: pass through the ring or x/5 A transformer only the phase conductor. If the whole cable is passed through (phase and neutral together), the currents cancel out and the device will show about 0 A.

    Selection matrix: all devices in the group

    U – voltage, I – current, f – frequency, P – active power, S – apparent power. Click a name to open the product page.

    Device Measures Range Current measurement Power supply Mounting
    DC voltmeter 0–40 V U 0–40 V DC – Separate wire (3 wires) Small panel, 0.56" LED
    DC voltmeter 0–100 V U 0–100 V DC – Separate wire (3 wires) Small panel, 0.56" LED
    DC voltmeter-ammeter 10 A U, I 0–100 V / 0–10 A DC Shunt included 4.5–30 V DC Small panel 48 × 29 mm
    DC voltmeter-ammeter 50 A U, I 0–100 V / 0–50 A DC Shunt 50 A / 75 mV 4.5–30 V DC Small panel 48 × 29 mm
    DC voltmeter-ammeter 100 A U, I 0–100 V / 0–100 A DC Shunt 100 A / 75 mV 4.5–30 V DC Small panel 48 × 29 mm
    AC voltmeter 80–500 V U 80–500 V AC – From the measured voltage Panel 70 × 42 mm
    AC ammeter 0–60 A I 0–60 A AC Ring CT included From the mains Panel 70 × 42 mm
    AC voltmeter-frequency meter U, f 100–300 V / 10–100 Hz – From the measured voltage Panel 70 × 42 mm
    AC voltmeter-ammeter U, I 100–300 V / 0–100 A AC Ring CT included From the measured voltage Panel
    AC multimeter with kWh U, I, P, kWh 80–260 V / up to 100 A CT included From the measured voltage Panel, LCD
    AC multimeter with cos φ U, I, P, S, cos φ 80–300 V / 0–100 A CT included From the measured voltage Cut-out 76 × 39 mm
    DigiTOP voltmeter 1-ph U 40–400 V AC – From the measured voltage 68 × 68 mm
    DigiTOP voltmeter 3-ph U ×3 40–400 V AC – From the measured voltage 68 × 68 mm
    DigiTOP ammeter 1-ph I 1–63 A AC CT included From the mains 68 × 68 mm
    DigiTOP ammeter 3-ph I ×3 1–63 A AC CT included From the mains 68 × 68 mm
    Ammeter with relay, CT 50/5 A I + relay 5 A up to 50 A AC 50/5 A CT included 150–270 V AC Cut-out 91 × 91 mm
    Ammeter with relay, CT 100/5 A I + relay 5 A up to 100 A AC 100/5 A CT included 150–270 V AC Cut-out 91 × 91 mm
    Ammeter with relay, CT 150/5 A I + relay 5 A up to 150 A AC 150/5 A CT included 150–270 V AC Cut-out 91 × 91 mm
    Ammeter with relay, CT 200/5 A I + relay 5 A up to 200 A AC 200/5 A CT included 150–270 V AC Cut-out 91 × 91 mm
    Ammeter with relay, CT 400/5 A I + relay 5 A up to 400 A AC 400/5 A CT included 150–270 V AC Cut-out 91 × 91 mm
    Ammeter with relay, CT 600/5 A I + relay 5 A up to 600 A AC 600/5 A CT included 150–270 V AC Cut-out 91 × 91 mm
    Ammeter with relay, CT 800/5 A I + relay 5 A up to 800 A AC 800/5 A CT included 150–270 V AC Cut-out 91 × 91 mm
    Ammeter with relay, without CT I + relay 5 A up to 800 A (via CT) x/5 A CT separately 150–270 V AC Cut-out 91 × 91 mm

    ⚠ What to check before buying

    Kibirkštis
    KibirkštisBefore buying, answer these questions – this is where mistakes are most often made.
    • AC or DC? Mains, generator or inverter output – AC; battery and solar module side – DC.
    • Maximum voltage and current. The device range must have a margin (e.g. for a 63 A supply – not a 60 A ammeter).
    • How will the device be powered? DC V/A with shunt needs 4.5–30 V DC; for a 48 V system – a separate source.
    • Does the wire fit through the transformer ring or is there room for the shunt?
    • Mounting cut-out. Small 48 × 29, 70 × 42, 76 × 39, 68 × 68 or 91 × 91 mm – check the space on the board door.
    • Only display, or also control? Disconnecting the load requires a device with a relay and a contactor.
    • Is MID required? For billing with a supplier or tenant – only a MID meter, not a panel meter.

    ✗ Most common mistakes

    Mistake What happens How to do it right
    The whole cable is passed through the transformer Phase and neutral currents cancel out – shows 0 A Pass only the phase conductor
    DC shunt connected in the positive circuit The device is damaged Shunt – only in the negative circuit
    AC meter used in a car or on a battery Does not work – AC devices measure 80–500 V alternating voltage For 12/24 V systems – DC voltmeter or DC V/A
    DC V/A with shunt in a 48 V system powered from the same voltage Supply exceeds 30 V – the device is damaged Separate 4.5–30 V DC supply
    100–300 V device connected between two phases (400 V) Voltage limit exceeded Phase–neutral or an 80–500 V voltmeter
    Ammeter with relay regarded as protection Short circuit or overload is not disconnected The circuit breaker stays in the circuit; the relay controls the contactor
    x/5 A CT secondary circuit is opened while current flows Dangerous voltage appears, the transformer may fail First short-circuit the CT terminals
    Fazė

    ⚡ Safe installation – Fazė's advice

    • Before installation, disconnect the circuit and verify that there is no voltage.
    • Protect voltage measurement and supply wires with a separate fuse or circuit breaker (e.g. 1–2 A).
    • A meter is not protection: a circuit breaker or fuses always remain in the line.
    • Never leave the secondary circuit of x/5 A transformers open while current flows.
    • Terminals must remain inside a closed board; 230/400 V devices are installed by a qualified electrician.

    Frequently asked questions

    Can I use an AC voltmeter in a car?
    No. AC devices measure 80–500 V alternating voltage; for cars and batteries choose a DC voltmeter or a DC voltmeter-ammeter.
    What is the difference between an ammeter and a multimeter?
    An ammeter shows only current; a multimeter shows several parameters – e.g. V, A, W and kWh or a V, A, W, VA and cos φ.
    Is a panel meter suitable for electricity billing?
    No, it has no MID approval; billing requires a MID-certified meter.
    How to monitor a three-phase supply?
    The most convenient option – three-phase voltmeter and three-phase ammeter; for higher currents – three ammeters with x/5 A transformers.
    Does an ammeter with relay disconnect the load by itself?
    Not directly: its 5 A relay controls a contactor, and the contactor disconnects the load.
    What to choose for a generator?
    For voltage and frequency – AC voltmeter-frequency meter, for the load – AC voltmeter-ammeter.
    Do I need to cut the wire to measure current?
    For AC devices with a transformer – no; for DC devices with a shunt – the shunt is connected into the negative circuit.
    ⚠ This guide is for reference only. Before buying and connecting, check the parameters against the product description, the manufacturer's instructions and the marking on the device. The qualified electrician carrying out the installation is responsible for it. UAB „Elektrotechnikos sprendimai“ is not liable for a product selection made solely on the basis of this guide.

    Sources

    Meter, transformer and protection – in one order

    Panel voltmeters, ammeters, multimeters, current transformers, contactors and circuit breakers – all in one place. Send us a board diagram or a list of loads: we will select compatible components and send you a quote. The model you need is not in the catalogue? Some products are supplied to order.

    Get a quote

    Panel digital ammeters and voltmeters – reliable electrical parameter measuring instruments designed for monitoring current (A) and voltage (V) in various electrical systems. They are installed directly in control cabinets, automation panels, industrial equipment, or domestic power distribution systems, allowing users to monitor the electrical network status in real time.

    These devices are essential for electricians, engineers, maintenance specialists, and home users who seek to ensure safe and efficient use of electrical energy.

    Main features

    Real-time voltage and current measurement – displays accurate electrical parameters.

    LED or LCD display – clear readings even in poorly lit environments.

    Low power consumption – economical and stable operation.

    Long service life – durable against mechanical and thermal stress.

    Universal installation – adaptable to different panels or equipment.

    Applications

    For home users: Suitable for home workshops, garages, generators, or distribution boxes. Enables monitoring of voltage and load current to prevent electrical device failures.

    For engineers: Used in automation systems, motor control cabinets, energy monitoring, and power supply testing where precision and stability are crucial.

    For electricians and technicians: Ideal for electrical installation, panel assembly, network testing, and fault diagnostics. Easy to install and suitable for both new and upgraded systems.

    For industrial equipment manufacturers: Ensures precise network monitoring in production lines, robotic systems, and energy distribution networks.

    Advantages

    Wide measurement range.

    Bright and clear digital display.

    Quick and easy panel mounting.

    Accurate readings and fast response time.

    Resistant to temperature fluctuations and vibration.

    Long lifespan with minimal maintenance.

    Disadvantages

    Some models are designed only for AC or DC – correct selection is important.

    Not recommended for outdoor use without additional protection.

    Panel digital ammeters and voltmeters are an integral part of electrical and automation systems, ensuring precise, fast, and reliable monitoring of voltage and current to prevent failures and network overloads. 

    Read more
    Panel digital AC ammeter | 0–60 A | ring current transformer | LED | ESDL85-LA
    Code: ESDL85-LA

    Panel digital AC ammeter 0–60 A with red LED display. Current is measured via the included ring current transformer.

    Price 12.28 € VAT incl.
    ( 10.15 € VAT excl. )
    Panel digital ammeter | 3-phase | LED | ±1 % | 96 × 96 mm | supply 220 V AC | ES-SDM-A96T
    Code: ES-SDM-A96T

    Three-phase LED digital ammeter designed for real-time current monitoring in three-phase electrical systems. The compact 96x96 mm panel design allows easy integration into electrical panels, while the bright LED display ensures clear data visibility even in demanding working conditions. This 3-in-1 ammeter simultaneously displays the currents of all three phases, making it an excellent choice for industrial facilities as well as commercial or residential installations. 

    Price 26.97 € VAT incl.
    ( 22.29 € VAT excl. )
    Panel digital ammeter with relay output | no CT, x/5 A up to 800/5 A | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04
    Code: ES-DA-VIP04

    Panel digital ammeter with adjustable current limit and relay output (5 A / 250 V AC). Used with an x/5 A current transformer (ratio settable up to 800/5 A). Supply 150–270 V AC, panel cut-out 91×91 mm.

    Price 35.07 € VAT incl.
    ( 28.98 € VAT excl. )
    Panel digital ammeter with relay output | CT 50/5 A included | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04-50
    Code: ES-DA-VIP04-50

    Panel digital ammeter with adjustable current limit and relay output (5 A / 250 V AC). Includes a 50/5 A current transformer – measures up to 50 A. Supply 150–270 V AC, panel cut-out 91×91 mm.

    Price 47.89 € VAT incl.
    ( 39.58 € VAT excl. )
    Panel digital ammeter with relay output | CT 100/5 A included | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04-100
    Code: ES-DA-VIP04-100

    Panel digital ammeter with adjustable current limit and relay output (5 A / 250 V AC). Includes a 100/5 A current transformer – measures up to 100 A. Supply 150–270 V AC, panel cut-out 91×91 mm.

    Price 37.49 € VAT incl.
    ( 30.98 € VAT excl. )
    Panel digital ammeter with relay output | CT 150/5 A included | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04-150
    Code: ES-DA-VIP04-150

    Panel digital ammeter with adjustable current limit and relay output (5 A / 250 V AC). Includes a 150/5 A current transformer – measures up to 150 A. Supply 150–270 V AC, panel cut-out 91×91 mm.

    Price 49.10 € VAT incl.
    ( 40.58 € VAT excl. )
    Panel digital ammeter with relay output | CT 200/5 A included | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04-200
    Code: ES-DA-VIP04-200

    Panel digital ammeter with adjustable current limit and relay output (5 A / 250 V AC). Includes a 200/5 A current transformer – measures up to 200 A. Supply 150–270 V AC, panel cut-out 91×91 mm.

    Price 51.52 € VAT incl.
    ( 42.58 € VAT excl. )
    Panel digital ammeter with relay output | CT 400/5 A included | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04-400
    Code: ES-DA-VIP04-400

    Panel digital ammeter with adjustable current limit and relay output (5 A / 250 V AC). Includes a 400/5 A current transformer – measures up to 400 A. Supply 150–270 V AC, panel cut-out 91×91 mm.

    Price 46.68 € VAT incl.
    ( 38.58 € VAT excl. )
    Panel digital ammeter with relay output | CT 600/5 A included | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04-600
    Code: ES-DA-VIP04-600

    Panel digital ammeter with adjustable current limit and relay output (5 A / 250 V AC). Includes a 600/5 A current transformer – measures up to 600 A. Supply 150–270 V AC, panel cut-out 91×91 mm.

    Price 70.88 € VAT incl.
    ( 58.58 € VAT excl. )
    Panel digital ammeter with relay output | CT 800/5 A included | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04-800
    Code: ES-DA-VIP04-800

    Panel digital ammeter with adjustable current limit and relay output (5 A / 250 V AC). Includes a 800/5 A current transformer – measures up to 800 A. Supply 150–270 V AC, panel cut-out 91×91 mm.

    Price 54.91 € VAT incl.
    ( 45.38 € VAT excl. )
    Panel digital ammeter with relay output | CT 1000/5 A included | 150–270 V AC | 91×91 mm cut-out | ES-DA-VIP04-1000
    Code: ES-DA-VIP04-1000

    This digital panel ammeter with adjustable overcurrent protection is designed for monitoring the current in an electrical circuit and protecting against overcurrents. It allows setting a maximum current limit and activates a relay if the current exceeds the set value. The device can function as a warning signal or automatically disconnect the circuit to protect systems from damage.

    High-precision measurement and a clear LED display allow quick current monitoring, while the built-in relay enables automatic on/off control. The device supports current transformer (CT) integration and allows easy configuration of system parameters. 

    Price 65.32 € VAT incl.
    ( 53.98 € VAT excl. )
    Panel digital AC voltmeter | 80–500 V AC | red LED | 2-wire | ESDL85-LV
    Code: ESDL85-LV

    Panel digital AC voltmeter 80–500 V AC with red LED display. 2-wire connection, no separate supply needed.

    Price 11.62 € VAT incl.
    ( 9.60 € VAT excl. )
    Panel digital AC voltmeter-frequency meter | 100–300 V AC | 10–100 Hz | LED | EL-DL85-2SLH
    Code: EL-DL85-2SLH

    Panel digital AC voltage and frequency meter: voltage 100–300 V AC (red display) and frequency 10–100 Hz (green display).

    Price 16.52 € VAT incl.
    ( 13.65 € VAT excl. )
    Panel digital AC voltmeter-ammeter | 100–300 V AC | 0–100 A | current transformer | EL-DL85-2SL
    Code: EL-DL85-2SL

    Panel-mount digital AC voltmeter-ammeter with dual LED display (red V, green A). Measures 100–300 V AC and 0–100 A AC via the included ring current transformer.

    Price 17.79 € VAT incl.
    ( 14.70 € VAT excl. )
    Panel digital AC multimeter | V, A, W, kWh | 80–260 V AC | 100 A | current transformer | LCD | ESTX-011
    Code: ESTX-011

    Panel digital single-phase AC meter with LCD: voltage 80–260 V, current up to 100 A, power and consumed energy (kWh). Current transformer included.

    Price 25.59 € VAT incl.
    ( 21.15 € VAT excl. )
    Panel digital AC multimeter | V, A, W, VA, cos φ | 80–300 V AC | 0–100 A | current transformer | ES-DL69-2048
    Code: ES-DL69-2048

    Panel digital single-phase AC multimeter: voltage 80–300 V, current up to 100 A, active power (W), apparent power (VA) and power factor (cos φ). Current transformer included.

    Price 38.12 € VAT incl.
    ( 31.50 € VAT excl. )
    Panel digital DC voltmeter | 0–40 V DC | 0.56" LED | 3-wire | EL-DC0-40
    Code: EL-DC0-40

    Panel digital DC voltmeter 0–40 V DC with 0.56" LED display. 3-wire connection: supply, common negative and measuring lead.

    Price 3.63 € VAT incl.
    ( 3.00 € VAT excl. )
    Panel digital DC voltmeter | 0–100 V DC | 0.56" LED | 3-wire | EL-DC0-100
    Code: EL-DC0-100

    Panel digital DC voltmeter 0–100 V DC with 0.56" LED display. 3-wire connection: supply, common negative and measuring lead.

    Price 4.36 € VAT incl.
    ( 3.60 € VAT excl. )
    Panel digital DC voltmeter-ammeter | 0–100 V DC | 0–10 A | shunt included | 4.5–30 V DC supply | EL-TX-1001
    Code: EL-TX-1001

    Panel digital DC voltmeter-ammeter: voltage 0–100 V DC (red display) and current 0–10 A (blue display). Current is measured via the included shunt. Meter supply 4.5–30 V DC.

    Price 7.26 € VAT incl.
    ( 6.00 € VAT excl. )
    Panel digital DC voltmeter-ammeter | 0–100 V DC | 0–50 A | shunt included | 4.5–30 V DC supply | EL-TX-1005
    Code: EL-TX-1005

    Panel digital DC voltmeter-ammeter: voltage 0–100 V DC (red display) and current 0–50 A (blue display). A 50 A / 75 mV shunt is included. Meter supply 4.5–30 V DC.

    Price 10.89 € VAT incl.
    ( 9.00 € VAT excl. )
    Panel digital DC voltmeter-ammeter | 0–100 V DC | 0–100 A | shunt included | 4.5–30 V DC supply | EL-TX-100
    Code: EL-TX-100

    Panel digital DC voltmeter-ammeter: voltage 0–100 V DC (red display) and current 0–100 A (blue display). A 100 A / 75 mV shunt is included. Meter supply 4.5–30 V DC.

    Price 14.52 € VAT incl.
    ( 12.00 € VAT excl. )
  • Subscribtion to new arrivals