Products catalog

  • PV DC isolator switch in enclosure | 4P | 32 A | 1200 V DC | DC-PV2 | MC4 | IP66 | ESTXPV2-40

    Code: ESTXPV2-40

    4-pole photovoltaic DC isolator in an IP66 enclosure with MC4-type connectors: 32 A, up to 1200 V DC, DC-PV2. Designed for safely isolating a solar module string from the inverter.

  • PV DC isolator switch in enclosure | 4P | 32 A | 1200 V DC | DC-PV2 | MC4 | IP66 | ESTXPV2-40

    ESTXPV2-40 is a manually operated DC switch-disconnector for isolating a solar module string from the inverter. The switching mechanism sits in a sealed IP66 enclosure with factory-fitted MC4-type connectors, so the string is plugged in without terminals or cable glands. The device complies with IEC 60947-3, utilization category DC-PV2.

    Key point:
    PV modules generate voltage whenever there is daylight, so the string must be reliably isolated before anyone touches the inverter or DC cabling. ESTXPV2-40 does this with one turn of the handle, even under operating current. Keep in mind: this is an isolation device, not a protective one – it does not protect against short circuit or overload.
    Rated current
    32 A
    Operating voltage
    up to 1200 V DC
    Utilization category
    DC-PV2 (IEC 60947-3)
    Enclosure and connection
    IP66, MC4-type connectors

    Operating principle

    The isolator is fixed to a wall or support structure between the module string and the inverter DC input. The string “+” and “−” cables with MC4 plugs go into the input connectors, and a cable from the output connectors continues to the inverter.

    Turning the handle to OFF opens four contacts simultaneously, breaking both string poles. Category DC-PV2 means the device is intended for switching a photovoltaic circuit under operating current, so there is no need to wait until dark. Good practice is still to switch off the inverter on the AC side first.

    Result: the inverter and the cable between isolator and inverter are de-energised from the module side, so you can replace the inverter, check connections or take measurements. The cables between modules and isolator remain live as long as the sun is shining.

    Why choose ESTXPV2-40?
    One product combines a DC-PV2 isolator, an IP66 enclosure suitable for outdoor use and ready-made MC4-type connectors. The installer does not have to source a box, glands and terminals separately – saving time and reducing the risk of DC wiring errors.

    Technical specifications

    Product type Photovoltaic DC isolator (switch-disconnector) in enclosure
    Manufacturer Elsp Group
    Product code ESTXPV2-40
    Number of poles 4P – both string poles are broken simultaneously
    Rated operational voltage (Ue) up to 1200 V DC
    Rated current (Ie) 32 A
    Rated insulation voltage (Ui) 1500 V DC
    Rated impulse withstand voltage (Uimp) 8 kV
    Utilization category DC-PV2
    Standards IEC 60947-3, AS 60947.3
    Connection Factory-fitted MC4-type connectors, 1 PV string (1 input / 1 output)
    Operation Manual rotary handle, ON / OFF positions
    Mounting Surface – on a wall or structure
    Ingress protection IP66 (enclosure)
    Operating temperature −40 °C … +85 °C
    Short-circuit and overload protection None – use gPV fuses or a DC circuit breaker

    Main functions

    • Both poles isolated at once – the inverter is separated from the string with no intermediate state where one pole is still connected.
    • DC-PV2 category – the isolator can be switched off under PV operating current, without waiting for the evening.
    • MC4-type connectors – the string is plugged in; no need to open the enclosure or seal cable glands.
    • IP66 enclosure – suitable for outdoor mounting – on a roof, façade or mounting structure.
    • Operating voltage up to 1200 V DC – suits longer strings, provided the string Voc at the lowest site temperature does not exceed 1200 V.
    • Clearly marked ON / OFF positions – service personnel can see at once whether the string is connected.

    Where is it used?

    • Next to the inverter – as a DC isolation point for servicing or inverter replacement
    • On the roof next to the module string – isolation closer to the source
    • Rooftop solar plants on private homes
    • Solar plants on commercial buildings, warehouses and farms
    • Ground-mounted plants – separate isolation of each string
    • Upgrades of existing plants that lack a DC isolation point
    • Hybrid systems – for the PV string input to the inverter only

    Use by need

    For PV installers.
    Ready MC4-type connectors and a sealed enclosure cut DC isolator installation down to a few minutes per string.
    For plant owners.
    During service or a fault, the technician safely isolates the DC side, and you can clearly see whether the plant is on.
    For company or farm technical managers.
    Each string has its own isolation point, so maintenance and fault-finding are done without stopping the whole plant.

    Practical application

    If the inverter is installed in a garage and the string cables come down from the roof, ESTXPV2-40 is mounted on the wall next to the inverter – one per string. When service is needed, the inverter is first switched off on the AC side, then the isolator is turned to OFF, and the inverter DC inputs are de-energised even while the sun is shining. The cable from the roof to the isolator remains live – treat it as live conductor.

    Pros

    • DC-PV2 category to IEC 60947-3
    • Operating voltage up to 1200 V DC, rated current 32 A
    • IP66 enclosure for outdoor installation
    • Factory-fitted MC4-type connectors
    • Wide operating temperature range: −40 °C … +85 °C
    • Clearly marked ON / OFF positions

    Cons / limitations

    • Does not protect against short circuit or overload – gPV fuses or a DC circuit breaker are required for that
    • Designed for one string – multiple strings need separate isolators or a string combiner box
    • Not suitable for AC circuits
    • Intended for PV strings; for battery DC circuits choose a device designed for that purpose
    • MC4-type connectors must be mated only with compatible plugs – mixing different systems can cause connector overheating

    Safety and installation notes

    • In daylight a string always generates voltage – the cables between modules and isolator stay live even with the isolator OFF.
    • A DC arc does not extinguish itself like an AC arc – never unplug MC4 connectors under load; switch off the inverter first, then the isolator.
    • Do not operate the isolator if a fault is suspected (short circuit, insulation damage, signs of overheating) – remove the cause first or work when the string is not generating.
    • Check that the string Voc at the lowest site temperature does not exceed 1200 V DC.
    • Observe polarity and input / output marking: module string to the input, inverter to the output; check polarity with a meter before switching on.
    • Secure the cables so that MC4 connectors are not under tension and do not touch sharp edges.
    • Installation and connection must be carried out by a qualified electrician in accordance with applicable wiring regulations.

    Quick selection guide

    4P
    32 A
    1200 V DC
    DC-PV2
    IP66
    MC4
    Suitable when you need:
    • a DC isolation point next to the inverter or at the modules
    • isolation of one PV string up to 32 A and 1200 V DC
    • outdoor mounting without an additional box
    Check before use:
    • string current with margin (typically 1.25 × Isc) does not exceed 32 A
    • string Voc at the lowest site temperature does not exceed 1200 V DC
    • compatibility of the MC4-type connectors with your cable plugs
    • whether overcurrent protection (gPV fuses or a DC circuit breaker) is installed in the circuit where required
    Important reminder: The isolator is not a protective device – it does not replace gPV fuses, a DC circuit breaker or a surge protective device (SPD).

    FAQ

    Does this isolator protect against short circuit?
    No – it is an isolation device; overcurrent protection requires gPV fuses or a DC circuit breaker.
    Why does the code say “40” when the current is 32 A?
    “40” is part of the model designation; for design purposes use the rated current of 32 A.
    Can I switch the isolator off while the plant is generating?
    Yes, category DC-PV2 allows switching under operating current, but it is recommended to switch off the inverter first.
    How many strings can be connected?
    One PV string – the isolator has one MC4-type input and one output.
    Is it suitable for outdoor installation?
    Yes, the enclosure is rated IP66 and the operating temperature is from −40 °C to +85 °C.
    Can it be used in an AC circuit?
    No, the device is intended for photovoltaic DC circuits only.

    PV DC isolator switch in enclosure | 4P | 32 A | 1200 V DC | DC-PV2 | MC4 | IP66 | ESTXPV2-40

    ESTXPV2-40 is a 4-pole photovoltaic DC isolator in an IP66 enclosure with MC4-type connectors: 32 A, up to 1200 V DC, DC-PV2 to IEC 60947-3. It is designed for safely isolating a solar string from the inverter; for overcurrent protection use gPV fuses or a DC circuit breaker.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Solar PV cable | H1Z2Z2-K | 1x4 mm² | black | 1.5 kV DC | EN 50618 | Dca | IEMMEQU HAR
    Code: H1Z2Z2K

    The cable is designed for connecting photovoltaic (solar energy) systems and interconnecting solar modules. This cable offers excellent resistance to ultraviolet (UV) rays, ozone, atmospheric effects, and temperature fluctuations. A durable and flexible single-core copper cable with double insulation ensures long service life and safe use even in the most challenging outdoor conditions. Suitable for installation both indoors and outdoors.

    Price 0.98 € VAT incl.
    ( 0.81 € VAT excl. )
    U-FTP cable | 6A CAT | 4x2x23 AWG | shielded | copper | UV resistant | for outdoor use | 1m | black | ALANTEC | KIF6AOUTS500
    Code: KIF6AOUTS500

    The U/FTP cable is a high-quality four-pair data transmission cable designed for telecommunication, industrial, and outdoor network installations. This cable is 100% copper, ensuring maximum signal transmission efficiency and minimal signal attenuation.

    It is adapted for 10 Gigabit Ethernet (10GBASE-T) data transmission at speeds of up to 10,000 Mbps and provides high electromagnetic resistance, as each pair is shielded with aluminum foil. Thanks to the PE outer layer, the cable is resistant to moisture, UV radiation, and mechanical impact, making it ideal for outdoor installations. 

    Price 0.73 € VAT incl.
    ( 0.60 € VAT excl. )
    Network plug | RJ45 connector (8P8C) | for UTP CAT 6e cable | unshielded | through-plug | transparent
    Code: WT117

    This RJ45 Cat.6 UTP modular plug is a high-quality 8P8C unshielded network connector type, designed for Cat.6 UTP (Unshielded Twisted Pair) cables. The special straight-through design makes cable termination easier and more convenient, as the wires can be threaded through the plug, allowing a visual check of the wire arrangement before crimping the connector.

    Price 0.20 € VAT incl.
    ( 0.17 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information