Passive Franklin lightning rod | aluminum alloy | telescopic | 2000mm | D18mm
Code: AL18MM2MAluminum alloy lightning rod – designed for effective collection of lightning current and safe discharge into the grounding system, this component is made from high-quality aluminum alloy, ensuring corrosion resistance, easy installation, and long service life. Thanks to its universal threaded base, the lightning rod can be easily adapted to various structures: on rooftops, structural frames, and supports.
-
Technical Specifications:
Material: Aluminum alloy (Alu)
Diameter: 18 mm
Length: 2000 mm (1 meter)
Base type: with thread
Standard: Complies with LST EN 62561-2 (Lightning protection system component standard)
Functions:
Effectively collects lightning discharge and directs it to ground
Lightweight, resistant to environmental effects
Used in various building lightning protection systems
Applications:
Roof lightning protection for residential and industrial buildings
Protection of solar power plants from direct lightning strikes
Protection of engineering structures (towers, antennas, tanks)
Mounting can be done using lightning rod holders, clamps, or connectors suitable for a 18 mm rod. Installation must follow LST EN 62305 and LST EN 62561 standards.
Pros:
Lightweight and durable – made of aluminum alloy, ideal for roof installation
Complies with LST EN 62561-2
Corrosion-resistant – long-lasting even in harsh weather
Cons:
Aluminum is not suitable for direct contact with copper – proper insulation from other metals is required due to potential electrochemical corrosion
A professional grounding system is necessary – improper installation may reduce protection efficiency
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.Active lightning protection – the active lightning rod is raised at the highest point of the building. This system attracts the forming lightning and directs all the current away from other elements of the building. The activity occurs only during a lightning discharge. When choosing an active lightning rod, pay attention to whether the lightning receiver has electronics (can withstand up to 115kA, but may fail if the discharge exceeds the limits) or no electronics (can withstand any strength and number of lightning discharges). Used for the protection of industrial complexes, buildings, residential houses, estates, warehouses, and stadiums.

Passive lightning protection – metal elements installed on the roof (traditional "Franklin" lightning rod). During a lightning strike, the current flows through this metal system into the ground. Typically, galvanized steel wire is used, which is laid along the entire roof length and dropped to the ground. Occasionally, copper wire is used, but due to cost differences, users usually opt for steel, which is cheaper. Around the building, a galvanized steel grounding strip is laid underground.

A lightning rod protects buildings and people from the effects of lightning, but does not protect equipment. Therefore, it is essential to install surge protection.
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Anti-corrosion paste | 0.5 kg | for grounding rod connections and contact protection | GalmarCode: 11301Price 10.12 € VAT incl.( 8.36 € VAT excl. )Modular surge protector 4P | 20kA | 275V | II/T2/C | DIN | Promfactor Baltic MOP4-C275/20Code: MOP4-C275/20Price 43.97 € VAT incl.( 36.34 € VAT excl. )Price 27.67 € VAT incl.( 22.87 € VAT excl. )Modular surge protector 2P | 40kA | 385VAC | DINCode: ES-TXSA-40KAPrice 17.18 € VAT incl.( 14.20 € VAT excl. )Surge protector PO I 1 280V/12.5kA 1P Class I+II+III (B+C+D) 12.5kA 1.3kVCode: SKU#158869360260671971Price 34.09 € VAT incl.( 28.18 € VAT excl. )Price 197.64 € VAT incl.( 163.34 € VAT excl. )