Power factor controller | 6 or 12 steps | Plug and Play | 144x144 | IP40 | Lifasa | MCE-6 ADV / MCE-12 ADV
Reactive power compensation steps Price Buy 12 steps Price 196.00 € VAT incl.Code: MCE12ADV400Add to wishlist6 steps Price 132.16 € VAT incl.Code: MCE06ADV400Add to wishlistLifasa MCE ADV – 6- or 12-step automatic power factor (cos φ) controller with Plug and Play commissioning: automatically detects the CT ratio (C/K), phase sequence and step program. Displays current, voltage and current THD, with alarms (LED and relay). CT /5 A, 144 × 144 mm, IP40. When ordering, specify the model: MCE-6 ADV or MCE-12 ADV.
-
Power factor controller | 6 or 12 steps | Plug and Play | 144x144 | IP40 | Lifasa | MCE-6 ADV / MCE-12 ADV
Lifasa MCE ADV is an automatic power factor (cos φ) controller for capacitor banks, available in 6-step (MCE-6 ADV) and 12-step (MCE-12 ADV) versions. It measures the reactive energy demand and switches capacitor steps on or off to maintain the set cos φ.
Key idea:
The main advantage of MCE ADV is simple commissioning. The controller automatically detects the CT ratio and the smallest step power (C/K), the phase sequence and CT polarity, the number of installed steps and their power program. This reduces commissioning errors when the electrician does not have all the cabinet data.Steps
6 (MCE-6 ADV) or 12 (MCE-12 ADV)Commissioning
Plug and Play – automatic C/K, phase and step detectionCurrent measurement
CT /5 A, 0.05–5 AHousing
144 × 144 mm, IP40 when mountedOperating principle
The controller is mounted in the cabinet door in a 138 × 138 mm cut-out. Voltage is connected between two phases (L2–L3 recommended), and current is measured by a current transformer with a /5 A secondary installed on phase L1 so that it measures the entire load, including the capacitors.
During initial commissioning, the controller switches the steps on one by one and automatically determines the C/K factor, phase matching and installed steps. If the CT is installed on a different phase or with reversed polarity, this is corrected in the menu – no rewiring is needed.
In operation, the steps are switched with a set delay between operations (4–999 s, factory setting 10 s), and the same step is reconnected no earlier than after 5 × T – giving the capacitor enough time to discharge.
Why choose MCE ADV?
It is a reliable, straightforward controller for a typical automatic capacitor bank: quick to commission, it displays current, voltage and current THD, records maximum values and raises an alarm for under- or over-compensation.Technical specifications
Product type Automatic power factor (cos φ) controller Manufacturer / series Lifasa / MCE ADV Models MCE-6 ADV (6 steps), MCE-12 ADV (12 steps) Supply voltage 230 / 400 / 480 V AC versions (see the device label for the exact voltage) Frequency 45–65 Hz, detected automatically Current measurement CT with /5 A secondary (not included), measuring range 0.05–5 A Measurement accuracy voltage ±1 %, cos φ ±2 % ±1 digit C/K setting 0.02–1, automatic or manual Step programs 1.1.1.1, 1.2.2.2, 1.2.4.4, 1.2.4.8, 1.1.2.2 Delay between steps 4–999 s (factory setting 10 s) Step reconnection after 5 × T Alarm LED and relay (a free step relay is used for the alarm) Display LCD, 1 line × 3 digits, 20 icons Dimensions 144 × 144 × 60 mm, mounting cut-out 138 × 138 mm Weight approx. 0.54 kg Degree of protection IP40 when panel-mounted (EN 60529) Electrical safety EN 61010-1, category III Standards EN 61010, EN 61000-3-2, EN 61000-3-3, EN 61000-6-1, EN 61000-6-3, UL 94 Key functions
- Plug and Play commissioning – automatically detects C/K, phase sequence, CT polarity and the step program
- Phase correction in the menu – no need to rewire the CT or voltage leads
- Parameter display – current, voltage and current THD % – you can quickly see whether harmonics threaten the cabinet
- Maximum value logging – records the highest current and voltage
- Alarms – under- and over-compensation, overvoltage, overcurrent, CT disconnected, current too low
- Minimum number of switching operations – extends the life of contactors and capacitors
Where is it used?
- New automatic capacitor banks with up to 12 steps
- Controller replacement in old cabinets
- Production halls, workshops and warehouses with motors
- Pumping stations, boiler houses, ventilation and refrigeration plants
- Commercial buildings charged for reactive energy
- Agricultural sites with three-phase equipment
Use by need
For electricians replacing an old controller.
Automatic setup lets you commission the cabinet even without knowing the exact CT ratio or step ratings.For capacitor bank manufacturers.
One standard 144 × 144 mm controller for 6- and 12-step cabinets – fewer different components in stock.For site owners.
The alarm immediately shows when compensation stops working, so reactive energy charges do not come as a surprise.Practical application
If an old 6-step controller in a workshop has failed and there is no cabinet documentation, MCE-6 ADV is fitted into the same 138 × 138 mm cut-out, the CT and voltage are connected, and during commissioning the controller determines the steps and C/K by itself. All the electrician has to do is check the cos φ target and alarms.Pros
- Plug and Play – automatic C/K, phase and step detection
- Phase and CT polarity correction in the menu
- Displays current THD and maximum values
- Alarms via LED and relay
- Standard 144 × 144 mm format
- 6- or 12-step versions
Cons / limitations
- No Modbus communication – for remote monitoring choose MASTER06 / MASTER12
- Measurement via a single CT – for unbalanced loads MASTER with 3 CTs is more accurate
- The alarm relay requires a free step relay
- CT purchased separately
Safety and installation notes
- Before any work, disconnect the power supply and make sure the capacitors are discharged
- Never leave the CT secondary circuit open – short-circuit the terminals before disconnecting
- Install the CT at the incoming supply so that it measures both the load and the capacitor current
- Protect the power supply with 0.5–2 A gL fuses and the relay circuit with a 6 A C-curve circuit breaker or a 6 A gL fuse (as per the manufacturer's instructions)
- Check that the supply voltage matches the device label (230 / 400 / 480 V)
Quick selection guide
6 or 12 stepsCT /5 APlug and Play144 × 144 mmIP40Suitable when you need:- a simple, reliable controller for a typical capacitor bank
- quick commissioning without full cabinet documentation
- controller replacement in a standard 138 × 138 mm cut-out
Check before use:- the required number of steps (6 or 12)
- the supply voltage as per the label
- the CT ratio and its location at the incoming supply
- whether Modbus or 3 CTs are needed – if so, choose MASTER
Important reminder: A controller does not replace a harmonic assessment – if the site has many frequency inverters and high current THD, the cabinet needs detuning reactors.FAQ
What is the difference between MCE-6 ADV and MCE-12 ADV?
The number of steps: MCE-6 ADV controls 6 steps, MCE-12 ADV controls 12.Do I need to know the CT ratio before commissioning?
Not necessarily – the controller can determine the C/K factor automatically.Can an incorrectly installed CT be corrected?
Yes, the phase and polarity can be changed in the menu without rewiring.Does MCE ADV have Modbus?
No, for remote communication choose Lifasa MASTER06 or MASTER12.Does the controller display harmonics?
It displays current THD as a percentage, which helps assess the harmonic level.What is the mounting cut-out?
138 × 138 mm, with a 144 × 144 mm front.Disclaimer. This description is based on manufacturer data and is provided for information only. Final selection, connection and commissioning must be carried out by a qualified electrician in accordance with the site design and applicable requirements. UAB „Elektrotechnikos sprendimai“ accepts no liability for selection or connection carried out solely on the basis of this description.Lifasa MCE ADV – 6 / 12-step cos φ controller with automatic commissioning
Lifasa MCE-6 ADV and MCE-12 ADV automatically control capacitor steps, determine C/K, phases and the step program by themselves, display current, voltage and THD, and raise alarms for compensation faults. Standard 144 × 144 mm, IP40.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products






