Products catalog

  • Panel-mounted | digital | three-phase network analyser | 3P | X/5A | supply 85-265VAC / 95-300VDC | RS-485 Modbus | 96x96 | Lifasa | MCA PLUS II

    Code: MCAPLUSII

    Lifasa MCA PLUS II – panel-mounted three-phase network analyser, 96 × 96 mm. Measures true RMS voltage, current, power and cos φ via 3 CTs (X/5 A), in 4 quadrants. Accuracy 0.5 % (U, I), 2 S0 / alarm outputs, 2 relays, 2 digital inputs, RS-485 Modbus RTU. Supply 85–265 V AC / 95–300 V DC.

  • Panel-mounted | digital | three-phase network analyser | 3P | X/5A | supply 85-265VAC / 95-300VDC | RS-485 Modbus | 96x96 | Lifasa | MCA PLUS II

    Lifasa MCA PLUS II is a panel-mounted three-phase network analyser that measures true RMS values of voltage, current, power and cos φ. It is connected to four voltage terminals and three current transformers, and is powered by a separate single-phase supply of 85–265 V AC or 95–300 V DC.

    Key idea:
    MCA PLUS II is useful wherever you need to continuously monitor the parameters of a switchboard or incoming supply and transfer them to SCADA: it measures in four quadrants (consumption and generation at the same point), and has pulse and relay outputs plus RS-485 Modbus RTU.
    Measurement
    three-phase, 4 voltage terminals + 3 CTs
    Current input
    X/5 A
    Accuracy
    U and I 0.5 % ±2 dgt, power 1 % ±2 dgt
    Communication
    RS-485, Modbus RTU

    Operating principle

    The device is mounted in the switchboard door (96 × 96 mm). Voltage is connected directly up to 300 V phase–N / 520 V phase–phase, and current via three current transformers with a 5 A secondary. A separate circuit is used for the power supply.

    The analyser calculates true RMS values and shows them on a backlit LCD display with a touch-sensitive keypad. Instantaneous power, maximum power and cos φ / PF are additionally shown on an analogue bar scale.

    Data is transferred via RS-485 Modbus RTU, while the digital outputs can transmit energy pulses (S0) or alarms. The digital inputs are used for tariff switching or external signals.

    Why choose MCA PLUS II?
    One compact device replaces several meters in the switchboard door and lets you continuously monitor changes in load, cos φ and power – the basis for correctly sizing or verifying power factor correction.

    Technical specifications

    Product type Panel-mounted three-phase network analyser
    Manufacturer / model Lifasa / MCA PLUS II
    Measurement configuration three-phase, 4 voltage terminals and 3 CTs; suitable for low- and medium-voltage installations (via instrument transformers)
    Power supply single-phase 85–265 V AC / 95–300 V DC, −15 % / +10 %, 50–60 Hz, up to 4.2 VA
    Voltage measurement up to 300 V AC phase–N, up to 520 V AC phase–phase, 45–65 Hz
    Current measurement In / 5 A, continuous overload 1.1 In, burden 0.75 VA (CTs not included)
    Accuracy voltage and current 0.5 % ±2 digits, power 1 % ±2 digits
    Measurement 4-quadrant – consumption and generation
    Digital outputs 2 pcs (S0 or alarms), NPN open collector, up to 24 V DC / 50 mA
    Relay outputs 2 pcs
    Digital inputs 2 pcs (tariff selection or external alarms)
    Communication RS-485, Modbus RTU
    Display and controls backlit LCD, touch-sensitive keypad, LED alarm indicator
    Dimensions 96 × 96 × 63 mm
    Weight 0.4 kg
    Degree of protection rear and sides IP21; confirm the front IP rating on the version label
    Operating temperature −10 … +50 °C, humidity 5–95 % non-condensing
    Electrical safety category III 300 V AC / 520 V AC, class II (EN 61010)
    Standards EN 61010-1, IEC 61000-4-x, EN 61000-6-1, EN 61000-6-3, UL 94

    Key functions

    • Three-phase true RMS measurement – accurate values even with distorted current
    • 4-quadrant measurement – suitable for sites with a solar power plant – both consumption and generation are visible
    • Analogue visualisation – power, maximum power and cos φ visible at a glance, without the menu
    • S0 / alarm outputs – pulses for energy metering or a signal when limits are exceeded
    • Relay outputs – direct control of external signalling or automation
    • RS-485 Modbus RTU – integration into SCADA, BMS or an energy monitoring system

    Where is it used?

    • Doors of main and distribution switchboards
    • Capacitor banks – for cos φ and load monitoring
    • Energy consumption monitoring of production lines
    • Sites with a solar power plant (consumption and generation)
    • Building management systems (BMS)
    • Medium-voltage switchgear (via voltage and current transformers)

    Use by need

    For switchboard builders.
    The standard 96 × 96 mm format and wide supply range allow the same device to be used in a variety of switchboards.
    For the site energy manager.
    Continuously shows power, cos φ and maximum values, so changes in load or compensation are spotted quickly.
    For SCADA / BMS integrators.
    Modbus RTU, S0 outputs and digital inputs allow the device to be integrated into a common monitoring system.

    Practical application

    If a company is being charged for reactive energy, MCA PLUS II in the main switchboard will show when and by how much cos φ drops, and the data can be logged in a SCADA system via Modbus. Based on this data, the capacitor bank rating and steps are selected. For a short audit without installation, a portable analyser can be rented.

    Pros

    • Three-phase true RMS measurement
    • 4-quadrant measurement
    • 0.5 % accuracy (U, I)
    • 2 S0 / alarm outputs and 2 relays
    • 2 digital inputs
    • RS-485 Modbus RTU
    • Wide supply range, AC or DC

    Cons / limitations

    • CTs not included
    • Direct voltage measurement only up to 300 V phase–N – higher voltages require voltage transformers
    • Not a MID-approved billing meter
    • No control of compensation steps – this requires a cos φ controller

    Safety and installation notes

    • Before installation, disconnect the voltage and verify that it is absent
    • Never leave the CT secondary circuit open – use shorting terminals
    • Protect the voltage measurement circuit with fuses
    • Observe CT polarity (P1 on the supply side), otherwise power will be displayed incorrectly
    • Mount only in the switchboard door to ensure front-panel protection

    Quick selection guide

    3P, 4-wire
    X/5 A
    85–265 V AC / 95–300 V DC
    RS-485 Modbus
    96 × 96 mm
    Suitable when you need:
    • continuous monitoring of switchboard or incoming supply parameters
    • measurement of consumption and generation at the same point
    • data transfer to SCADA or BMS
    Check before use:
    • the CT ratio and quantity (3 pcs required)
    • the network voltage – whether voltage transformers are needed
    • the supply voltage (85–265 V AC or 95–300 V DC)
    • whether MID metering is required – other meters are designed for that
    Important reminder: The analyser only measures – it does not improve cos φ or control capacitors; that requires an automatic controller and a capacitor bank.

    FAQ

    Does MCA PLUS II measure a three-phase network?
    Yes, it is connected to four voltage terminals and three current transformers.
    What does "1P" supply mean?
    The device is powered by a single-phase 85–265 V AC or 95–300 V DC supply, but measures a three-phase network.
    Are the current transformers included?
    No, three CTs with a 5 A secondary are required, selected according to the incoming supply current.
    Can it be connected to SCADA?
    Yes, via RS-485 Modbus RTU.
    Is it suitable for a site with a solar power plant?
    Yes, 4-quadrant measurement shows both consumed and generated energy.
    Is it a billing meter?
    No, it is a network analyser for monitoring, not a MID-approved billing meter.
    Disclaimer. This description is based on manufacturer data and is provided for information only. Final selection, connection and commissioning must be carried out by a qualified electrician in accordance with the site design and applicable requirements. UAB „Elektrotechnikos sprendimai“ accepts no liability for selection or connection carried out solely on the basis of this description.

    Lifasa MCA PLUS II – panel-mounted three-phase network analyser 96 × 96 mm

    Lifasa MCA PLUS II measures three-phase voltage, current, power and cos φ in four quadrants, with S0 / alarm and relay outputs, digital inputs and RS-485 Modbus RTU. Supply 85–265 V AC / 95–300 V DC, CT X/5 A.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.