Products catalog

  • Relay socket | OMRON MY4 | 5 A | 250 V AC | DIN 35 mm | OMRON PYF14A-E

    Code: PYF14A-E

    OMRON PYF14A-E – socket for OMRON MY4 relays, mounted on DIN rail. Screw terminals; the relay can be replaced without disconnecting wires.

  • Relay socket | OMRON MY4 | 5 A | 250 V AC | DIN 35 mm | OMRON PYF14A-E

    OMRON PYF14A-E is a socket for OMRON MY4 relays. The relay plugs into the socket and the wires connect to the socket screw terminals, so the relay can be replaced without disturbing the wiring.

    Key point:
    A plug-in relay cannot be connected without a socket. A socket with screw terminals lets you mount the relay on a DIN rail and replace a faulty relay in seconds without disconnecting wires.
    Compatible relays
    OMRON MY4 (4CO)
    Rated current
    5 A / 250 V AC
    Number of pins
    14
    Mounting
    35 mm DIN rail or screw mounting

    Operating principle

    The socket snaps onto a 35 mm DIN rail. Coil (A1–A2) and contact wires connect to the screw terminals according to the diagram marked on the socket.

    The relay is plugged in and secured with the clip so it does not fall out due to vibration.

    When needed, the relay can be pulled out and replaced without disconnecting a single wire.

    Why choose OMRON PYF14A-E?
    OMRON PYF14A-E – a 14-pin socket for 4-pole MY4 series relays. Mounts on DIN rail or screws to a panel, with front-mounted terminals.

    Technical specifications

    Product type Relay socket for DIN rail mounting
    Manufacturer / code OMRON PYF14A-E
    Compatible relays OMRON MY4 (MY4N, MY4IN, MY4ZN…)
    Number of pins 14 (4CO)
    Rated current 5 A
    Max. switching voltage 250 V AC
    Terminals screw (M3)
    Insulation coil–contacts 2000 V AC (1 min)
    Mounting 35 mm DIN rail or screw mounting
    Retaining clip PYC-A1 (sold separately)
    Standards / approvals UL, CSA, CE, VDE

    Main functions

    • Screw terminals – reliable wire connection in the panel.
    • DIN rail – mounting next to other modular devices.
    • Fast relay replacement – wires stay connected.
    • Marked terminals – clear coil and contact numbering.
    • Retaining clip – the relay does not fall out due to vibration.

    Where is it used?

    • Automation and control panels
    • PLC input/output interfaces
    • Industrial machinery control cabinets
    • Building automation panels
    • HVAC control panels
    • Repair and replacement of faulty relays

    Use by need

    Panel builder.
    Neat relay mounting on DIN rail with clear terminal numbering.
    Maintenance technician.
    Replace the relay without disconnecting wires – shorter downtime.
    Automation integrator.
    A standard socket that fits the whole relay series.

    Practical application

    If an interface relay fails in the panel, it is simply pulled out of the socket and a new one plugged in – the wires stay on the socket terminals, the circuit does not change and downtime is a few minutes.

    Pros

    • DIN rail mounting
    • Relay replacement without disconnecting wires
    • Clearly marked terminals
    • DIN rail or panel mounting

    Cons / limitations

    • Rated current 5 A
    • PYC-A1 retaining clip sold separately
    • Fits only the specified relay series
    • Socket current is also limited by the relay ratings – the lower value applies

    Safety and installation notes

    • Install and replace relays only with the supply disconnected.
    • Tighten wires to the recommended torque; do not exceed the terminal cross-section.
    • Use only compatible relays and retaining clips.
    • Protect the socket circuit with a circuit breaker or fuse.

    Quick selection guide

    MY4
    5 A / 250 V AC
    14 pin
    DIN
    Suitable when you need:
    • to mount a plug-in relay on DIN rail
    • to replace relays without disconnecting wires
    • to assemble an automation panel neatly
    Check before use:
    • that the relay series fits this socket
    • wire cross-section and terminal type
    • space in the panel (width, height under the cover)
    Important reminder: a socket is not a protective device – the circuit must be protected by a circuit breaker or fuse.

    FAQ

    Which relays fit?
    This socket is designed for OMRON MY4 relays.
    Is the relay included?
    No, the relay is sold separately.
    How is it mounted?
    It snaps onto a 35 mm DIN rail.
    Can the relay be replaced without disconnecting wires?
    Yes, that is the main advantage of a socket.
    Does the socket protect the circuit?
    No, the circuit must be protected by a circuit breaker or fuse.
    Do you help with selection?
    Yes, send us the relay code – we will select a suitable socket and accessories.

    Relay socket | OMRON MY4 | 5 A | 250 V AC | DIN 35 mm | OMRON PYF14A-E

    OMRON PYF14A-E – socket for OMRON MY4 relays, DIN rail mounting, with screw terminals for fast relay replacement in automation panels.

    Published: 2026-11-05 · Data verified against the manufacturer datasheet: 2026-11-05

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Modular photo relay | twilight switch with external sensor | 16 A | 12–240 V AC/DC | 1–50,000 lx | 1CO | DIN | GanzKK | SOU-1/UNI
    Code: SOU-1/UNI

    DIN rail twilight switch with universal 12–240 V AC/DC supply and external sensor: 1–50,000 lx, 1CO 16 A AC1, 0–2 min delay, 1 module.

    Price 42.47 € VAT incl.
    ( 35.10 € VAT excl. )