  • Ring cable lug | 10mm² | M6 | crimp | KDR 10/6

    Code: KDR 10/6

    Crimp ring cable lug for 10 mm² copper conductors, M6 stud. For terminating a cable or wire end and connecting it reliably to a terminal, busbar or device bolt.

  • Ring cable lug | 10mm² | M6 | crimp | KDR 10/6

    KDR 10/6 – crimp ring cable lug 10 mm² for a copper conductor with a stud hole for an M6 bolt. Used to terminate a cable or wire end and connect it reliably to a terminal, busbar or device bolt.

    Key idea:
    The lug is selected by two values: conductor cross-section (10 mm²) and the size of the bolt it is connected to (M6). Small cross-section lugs are used in control circuits, panels and equipment connections. A correctly crimped lug forms a mechanically strong, low-resistance connection.
    Conductor cross-section
    10 mm²
    Stud hole
    M6
    Connection
    crimp
    Series / marking
    KDR 10/6

    Operating principle

    Insulation is stripped from the conductor to the depth of the lug barrel and the strands are pushed fully into the barrel.

    The barrel is crimped with a crimping tool using a die for 10 mm². During crimping the barrel deforms together with the conductor – a solid joint is formed without a screw contact on the strands.

    The ring part with the M6 hole is bolted to the terminal or busbar, and the crimp area is insulated with heat-shrink tubing.

    Why choose KDR 10/6?
    An exact cross-section and bolt combination (10 mm² / M6) – no need to enlarge the hole or crimp a wrong-size lug, so the joint stays reliable throughout its service life.

    Technical specifications

    Product type Crimp ring cable lug
    Marking / code KDR 10/6
    Series KDR
    Conductor cross-section 10 mm²
    Stud hole (bolt) M6
    Conductor copper
    Connection method crimping

    Main functions

    • Conductor termination – the 10 mm² conductor is secured and does not splay under the bolt.
    • Crimped joint – strong mechanical and electrical connection without an extra screw on the strands.
    • M6 stud hole – fits an M6 bolt or stud directly.
    • KDR series – lugs of one type across the whole range of cross-sections and bolt sizes.
    • Easy identification – cross-section and bolt size are given in the marking KDR 10/6.

    Where is it used?

    • Control and automation panels
    • Earthing and equipotential bonding conductors
    • Motor and pump terminals
    • Heating and ventilation equipment connections
    • Auxiliary circuits of solar plants and inverters
    • Production equipment repair

    Use by need

    For the installing electrician.
    One clear 10 mm² / M6 combination – fewer errors when building a panel.
    For the equipment repair technician.
    A damaged or overheated lug is replaced with a product of the same size.
    For the designer and buyer.
    The complete KDR series – from small to large cross-sections.

    Practical application

    If a 10 mm² copper cable has to be connected in a panel to a busbar or device with an M6 bolt, use KDR 10/6: strip the insulation, push the conductor into the barrel, crimp with a 10 mm² die and insulate the joint with heat-shrink tubing.

    Advantages

    • Exact cross-section and bolt combination
    • Reliable crimped joint
    • Suitable for copper conductors
    • Consistent series system
    • Compact ring part

    Disadvantages / limitations

    • Uninsulated – the crimp area must be insulated with heat-shrink tubing
    • Requires a crimping tool and the correct die
    • Not suitable for aluminium conductors – use bimetallic lugs
    • A lug of the wrong cross-section will not form a reliable joint

    Safety and installation notes

    • Install only with the voltage disconnected and its absence verified
    • Use a die intended for 10 mm²
    • Push the conductor to the end of the barrel, leave no protruding strands
    • Do not crimp several conductors in one lug unless intended
    • Tighten the bolt to the torque specified by the equipment manufacturer
    • After installation, check that the joint does not heat up under load

    Quick selection guide

    10 mm²
    M6
    crimp
    KDR
    for copper
    Suitable when you need:
    • to terminate a 10 mm² copper conductor
    • to connect to an M6 bolt or stud
    • a durable crimped joint in a panel or device
    Check before use:
    • whether the conductor cross-section is exactly 10 mm²
    • whether the terminal bolt is M6
    • whether you have the right crimping tool and die
    • whether the conductor is copper (bimetallic lugs for aluminium)
    Important reminder: A lug does not replace insulation of the joint – cover the crimp area with heat-shrink tubing.

    FAQ

    How do I choose a ring lug?
    By the conductor cross-section (10 mm²) and the bolt size (M6) – both must match.
    Is it suitable for aluminium cable?
    No – bimetallic (Al/Cu) lugs are used for aluminium conductors.
    Which tool is used for crimping?
    Crimping pliers or a hydraulic press with a 10 mm² die.
    Can it be fitted to a larger bolt?
    No – the M6 hole is only for an M6 bolt; choose another lug for a different bolt.
    Does it need insulating?
    Yes – the lug is uninsulated; cover the crimp area with heat-shrink tubing.
    What is the difference between the T and TCD series?
    The TCD series is made to DIN 46235; T is another series in this group. Both are crimp lugs for copper conductors.

    Ring cable lug | 10mm² | M6 | crimp | KDR 10/6

    KDR 10/6 – crimp ring cable lug 10 mm² M6 for terminating copper conductors and connecting them to panels, busbars and equipment terminals.

    Published: 2026-11-12 · Parameters according to the supplier's specification: 2026-11-12

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    CYKY-L 5G10 | 5×10 mm² | Copper power cable | 450/750 V | black | 1 m | Lietkabelis
    Code: 91951013

    CYKY-L 5G10 (5×10 mm²) – 450/750 V copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. AB Lietkabelis, price per 1 m.

    Price 8.67 € VAT incl.
    ( 7.17 € VAT excl. )
    Modular three-phase smart energy meter with relay | 60 A | 3×230/400 V | Wi-Fi Tuya | remote control | U/I protection | RS485 | DIN | Tomzn TO-DTS238
    Code: TO-DTS238

    Three-phase DIN meter with a built-in relay for 3×230/400 V networks up to 60 A. Via Wi-Fi and the Tuya app it shows U, I, P, PF, frequency and imported / exported energy separately, and lets you switch the supply on / off remotely, set a timer and configure voltage / overload protection. It also has RS485 Modbus RTU; intended for non-billing (internal) metering.

    Price 145.20 € VAT incl.
    ( 120.00 € VAT excl. )
    Single-cable membrane entry flange | for Ø86 mm hole | cable Ø55–70 mm | flange Ø123.1 mm | grey | IP67 | HT Hi Tech Polymers | HTX-1
    Code: Sandariklis HTX-1

    HTX-1 is a membrane entry flange for one thick power cable Ø55–70 mm. It fits a round Ø86 mm hole in the enclosure wall, flange diameter Ø123.1 mm. Sealing rating is IP67 according to the latest manufacturer's sheet.

    Price 21.78 € VAT incl.
    ( 18.00 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information