Products catalog

  • Three-phase frequency inverter | 7.5 kW | 17 A | 3×400 V AC | IP20 | with EMC filter | for three-phase motor control | Eura Drives E810-0075 T3

    Code: E810-0075 T3

    Vector three-phase frequency inverter 7.5 kW / 17 A for 3×380–480 V mains: built-in PID, Modbus RS485, C3 EMC filter, induction and PMSM motors. Mounted in a control cabinet (IP20).

  • Three-phase frequency inverter | 7.5 kW | 17 A | 3×400 V AC | IP20 | with EMC filter | for three-phase motor control | Eura Drives E810-0075 T3

    EURA Drives E810-0075 T3 is a vector frequency inverter for three-phase induction motors and permanent magnet synchronous motors (PMSM) up to 7.5 kW. It is supplied from a 3×380–480 V network and smoothly controls motor speed by varying the output frequency from 0 to 590 Hz. The built-in PID controller and Modbus RS485 interface allow it to be used both on its own and as part of an automation system.

    Key point:
    A pump, fan or conveyor rarely needs to run at full power. A frequency inverter starts the motor without a current surge and keeps exactly the speed the process needs. In fan and pump systems this means direct electricity savings, less mechanical wear and quieter operation.
    Motor power
    up to 7.5 kW
    Rated current
    17 A
    Supply
    3×380–480 V AC
    Control
    PID | Modbus RS485

    Operating principle

    The inverter is wall-mounted in a control cabinet and connected between the three-phase mains and the motor. The input voltage is rectified to DC, then the output transistors form a three-phase voltage with adjustable frequency and amplitude.

    Speed is set on the keypad, with an analogue 0–10 V, 0–20 mA or 4–20 mA signal, or via Modbus RS485. Acceleration and deceleration time can be set from 0.1 to 3000 s. The built-in PID controller uses a sensor signal (pressure, temperature, level) to hold the required process value automatically.

    The result: smooth starting without inrush current, precise speed control and lower energy consumption at partial load.

    Why choose E810-0075 T3?
    One device replaces a star-delta starter, a damper or throttle and a separate controller. The pump or fan runs exactly as fast as the process requires, and the built-in EMC filter reduces mains interference without an extra filter.

    Technical specifications

    Product type Vector three-phase frequency inverter
    Manufacturer / series EURA Drives / E810
    Model E810-0075 T3
    Max. motor power 7.5 kW
    Rated output current 17 A
    Supply voltage 3×380–480 V AC
    Mains frequency 44–67 Hz
    Output voltage 3 phases, 0 … supply voltage
    Output frequency 0–590 Hz
    Overload 120 % – 60 s
    Motor types Induction and PMSM
    Acceleration / deceleration time 0.1–3000 s
    Digital inputs / outputs 6 / 1
    Analogue inputs 2 (0–10 V, 0–20 mA, 4–20 mA)
    Analogue outputs 2 (0–10 V)
    Communication RS485 Modbus
    Controller Built-in PID
    EMC filter Built-in, class C3 (industrial environment)
    Programming Keypad on the inverter or PC
    Connection Screw terminals
    Mounting Wall mounting (in a control cabinet)
    Protection class IP20
    Operating temperature -10…+40 °C

    Main functions

    • Vector control – stable torque even at low speed.
    • PMSM and induction motor support – also suitable for modern, more efficient motors.
    • Built-in PID controller – constant pressure, temperature or level without a separate controller.
    • Modbus RS485 – control and status reading from a PLC, SCADA or building management system.
    • 2 analogue inputs – speed reference and sensor feedback at the same time.
    • Adjustable acceleration and deceleration (0.1–3000 s) – lower risk of water hammer and mechanical wear.
    • Built-in C3 EMC filter – less interference with other equipment in an industrial environment.

    Where is it used?

    • Booster pumps for water supply pressure
    • Heating and circulation pumps in boiler rooms
    • Ventilation unit and smoke extraction fans
    • Conveyors and transporters
    • Compressors
    • Grain dryer and farm ventilation fans
    • Mixers, screw conveyors
    • Woodworking and metalworking machines

    Use by need

    For control panel builders.
    PID, 6 digital inputs and Modbus let you build pump station or ventilation control without extra modules.
    For building and boiler room operators.
    Reducing fan and pump speed to actual demand directly lowers the electricity bill.
    For farms and manufacturers.
    Smooth starting of conveyors, dryer fans and pumps protects the mechanics and does not load the mains.

    How does it differ from neighbouring models?

    Model Power / current IP When to choose
    E810-0075 T3 (this one) 7.5 kW / 17 A IP20 The inverter will be installed in a control cabinet
    EP66-0075T3 7.5 kW / 17 A IP66 Mounting next to the machine, damp or wash-down area, no cabinet
    E810-0110 T3 11 kW / 23 A IP20 Motor current above 17 A or heavy starting

    Practical example

    If an apartment building water pump (7.5 kW) runs at full power and pressure is controlled with a valve, then with E810-0075 T3 and a 4–20 mA pressure sensor the PID controller keeps constant pressure by changing pump speed. At night and at low water demand the pump runs slower, reducing energy consumption and water hammer in the pipework.

    Pros

    • Vector control, induction and PMSM motors
    • Built-in PID controller
    • Modbus RS485 for integration
    • Built-in C3 EMC filter
    • Wide supply range 380–480 V
    • Programming via keypad or PC

    Cons / limitations

    • IP20 – control cabinet only, not for outdoor or damp locations (choose the IP66 version outdoors)
    • Overload 120 % / 60 s – for heavy starting (crushers, cranes) choose a higher power model
    • Operating temperature up to +40 °C – a hot cabinet needs ventilation
    • The C3 filter is intended for industrial environments – residential buildings may need an additional filter

    Safety and installation notes

    • ⚡ Installation and connection must be carried out by a qualified electrician with the supply disconnected.
    • ⚡ After disconnection the DC link capacitors remain charged – wait the time specified by the manufacturer and check the voltage before touching the terminals.
    • Do not install contactors switched during inverter operation or power factor correction capacitors between the inverter and the motor.
    • Earth the inverter and the motor; use a shielded motor cable with the shield earthed at both ends.
    • A 230/400 V motor on a 3×400 V inverter output is connected in star (Y), a 400/690 V motor in delta (Δ).
    • Inverters with an EMC filter have increased leakage current – choose the residual current device type according to the manufacturer's instructions.
    • Leave free space for cooling above and below the inverter and mount it vertically.
    ☝ Elsprendimai.eu recommends:
    Before buying, see the Eura Drives three-phase inverter selection guide – it includes a selection table by motor current, a comparison of starting methods and wiring diagrams.

    Quick selection guide

    7.5 kW | 17 A
    3×380–480 V AC
    0–590 Hz | PID
    Modbus RS485 | IP20
    Suitable when you need to:
    • control the speed of a three-phase motor up to 7.5 kW / 17 A
    • hold constant pressure, flow or temperature from a sensor
    • control the drive from a PLC or SCADA via Modbus
    Check before use:
    • motor rated current not above 17 A, connection for 400 V (star or delta according to the motor nameplate)
    • whether fast braking is needed – then select a braking resistor according to the manufacturer's instructions
    • cabinet temperature and ventilation
    Important reminder: a frequency inverter does not replace short-circuit protection at the supply or the emergency stop circuit – these are installed separately.

    FAQ

    Can it be supplied from a single-phase 230 V network?
    No, E810-0075 T3 is supplied only from three-phase 3×380–480 V.
    Is it suitable for a 5.5 kW motor?
    Yes, it also works with smaller motors once the exact motor rated current is set in the parameters.
    Can it be controlled remotely?
    Yes, via RS485 Modbus or with an analogue 0–10 V / 4–20 mA signal from a controller.
    Is a separate EMC filter needed?
    Not in an industrial environment – a class C3 filter is built in; residential buildings may require an additional one.
    Can it be installed outdoors?
    No, the IP20 inverter is installed only in a closed control cabinet – outdoors choose the EP66 (IP66) version.
    Is it suitable for synchronous PMSM motors?
    Yes, the E810 series supports both induction and PMSM motors.

    Three-phase frequency inverter Eura Drives E810-0075 T3 | 7.5 kW | 17 A

    Vector 7.5 kW / 17 A frequency inverter for 3×400 V mains with built-in PID controller, Modbus RS485 and C3 EMC filter. Designed for speed control and energy saving of induction and PMSM motors in pumps, fans, compressors and conveyors.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Radial scroll-housing fan | steel | 230V | D120 | 128×207×188mm | blue | Turbo Classic 120 2P | 4772318404044
    Code: 03046

    Radial scroll-housing fan Turbo Classic 120 2P: 230 V, up to 450 m³/h, Ø120 mm connection, steel housing IP44. For local supply, extraction and cooling.

    Price 165.84 € VAT incl.
    ( 137.06 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information