Aluminium power cable | 4x35mm² | AXMK | Class 2 | 1m | black
Code: AXMK 4x35AXMK 4x35mm² – a four-core aluminium power cable designed for fixed transmission and distribution of electrical energy in 0.6/1 kV networks. The cable features Class 2 aluminium conductors, XLPE core insulation, and a black UV-resistant PVC outer sheath. Suitable for installation indoors and outdoors, directly in the ground, in concrete, cable ducts, and protective conduits. Maximum operating temperature – 90 °C.
-
Aluminium Power Cable | 4x35mm² | AXMK | 0.6/1kV | Black Aluminium Power Cable | 4x35mm² | AXMK | 0.6/1kV | Class 2 | Black
AXMK 4x35mm² aluminium power cable – a four-core cable designed for fixed transmission and distribution of electrical energy in low-voltage electrical networks. The cable conductors are made of aluminium, the insulation is XLPE, and the outer sheath is black PVC. The cable is suitable for installation outdoors, underground, in dry, damp and wet rooms, directly in concrete, in cable ducts and in protective conduits. The outer sheath is resistant to UV radiation.
0.6/1kV aluminium cable for fixed electrical installationsFour 35mm² aluminium conductors are designed for electrical energy transmission and distribution in fixed systems. The XLPE insulation is rated for a maximum operating temperature of up to 90°C, while the black PVC sheath allows the cable to be used in various indoor and outdoor installation conditions.
4x35mm²Number of cores and cross-section600/1000VRated voltage90°CMax. operating temperatureClass 2Aluminium conductorConstruction and materials
Construction element Material / type Purpose Conductor Aluminium For transmission and distribution of electrical energy. Conductor class Class 2 Designed for fixed cable installation in electrical systems. Insulation XLPE Electrical insulation of the cores, rated for operating temperatures up to 90°C. Outer sheath PVC External cable protection during installation and operation. Sheath colour Black UV-resistant outer sheath. Installation options
- Outdoor electrical installations
- Directly underground
- Dry rooms
- Damp rooms
- Wet rooms
- Directly in concrete
- Cable ducts
- Protective conduits
UV resistanceThe black outer PVC sheath is resistant to UV radiation, therefore the cable can also be used in outdoor electrical installations when appropriate cable installation conditions are observed.
XLPE insulationXLPE is used for the core insulation, therefore the specified maximum operating temperature of the cable is 90°C. This insulation is widely used in fixed power cables due to its good electrical and thermal properties.
Technical specification
Cable type AXMK Application Aluminium power cable Number of cores 4 Cross-section of each core 35mm² Conductor material Aluminium Conductor class Class 2 Rated voltage 600/1000V AC (0.6/1kV) Insulation XLPE Outer sheath PVC Colour Black Maximum operating temperature 90°C UV resistance Yes Outdoor installation Yes Underground installation Yes Installation in concrete Yes Advantages / benefits
- 4x35mm² aluminium conductors are designed for fixed electrical energy transmission and distribution.
- 0.6/1kV rated voltage is suitable for standard low-voltage power systems.
- XLPE core insulation is rated for operating temperatures up to 90°C.
- UV-resistant sheath allows the cable to be used in outdoor installations.
- Wide range of installation methods – suitable for installation underground, in concrete, ducts, conduits and various indoor environments.
- Aluminium conductor allows large cross-section power lines to be constructed using aluminium cable systems.
- Class 2 conductor is suitable for fixed cable installation.
Disadvantages / limitations
- Aluminium conductor: terminals, lugs and suitable installation methods intended for aluminium or Al/Cu connections must be used.
- Class 2 conductor: the cable is intended for fixed installation and not for continuous flexing or supplying moving equipment.
- Large cable cross-section: appropriate cable tools and correctly sized connection components are required for installation and termination.
- 0.6/1kV class: the cable must not be used in systems whose rated voltage exceeds the cable's specified voltage class.
What is it suitable for? (Applications)
- Main building power supply lines
- Electrical distribution systems in industrial facilities
- Power supply to electrical panels and distribution cabinets
- Outdoor electrical installations
- Underground cable line installations
- Dry, damp and wet rooms
- Installation in cable ducts and conduits
- Fixed 0.6/1kV electrical energy transmission lines
What is it not suitable for?
- Moving or continuously flexing equipment
- Systems with a rated voltage higher than 0.6/1kV
- Connection to terminals or connectors that are not designed for aluminium conductors
- Installations where the electrical design requires a different cable type or construction
Practical example
A fixed electrical power supply line needs to be installed from the main distribution board to another electrical panel at a separate location. Part of the cable route runs inside the building, while another part runs outdoors and underground. An AXMK 4x35mm² cable may be used for such an installation if its cross-section, voltage class and other parameters meet the requirements of the specific electrical design. The cable ends must be terminated using lugs and connection components suitable for aluminium conductors.
Frequently asked questions (FAQ)
How many cores does this cable have?The cable has 4 cores, each with a cross-section of 35mm².
What material are the conductors made of?The cable conductors are made of aluminium and are Class 2.
What is the rated voltage of the cable?The rated voltage of the cable is 600/1000V, or 0.6/1kV.
Can the cable be installed underground?Yes. According to the provided product information, the cable can be installed underground.
Can the cable be used outdoors?Yes. The cable's outer sheath is resistant to UV radiation, therefore the cable is suitable for outdoor installations.
Can the cable be installed in concrete?Yes. According to the provided specification, the cable can be installed directly in concrete.
What insulation does the cable use?The core insulation is XLPE, while the outer cable sheath is PVC.
What is the maximum operating temperature?The specified maximum operating temperature of the cable is 90°C.
Can an aluminium cable be connected to standard copper terminals?The terminals must be explicitly suitable for aluminium conductors or Al/Cu connections. The connection method and cable lugs must be selected according to the requirements of the equipment manufacturer.
Important installation noteThe cable cross-section must be selected according to the electrical design, load, line length, installation method, environmental conditions, permissible voltage drop and applicable electrical installation requirements. For aluminium conductor connections, use only terminals, lugs and installation methods suitable for aluminium or Al/Cu connections. Electrical installation work must be carried out by a qualified specialist.
AXMK 4x35mm² – a 0.6/1kV aluminium power cable with XLPE insulation and a black PVC sheath, designed for fixed electrical energy transmission and distribution lines in indoor, outdoor, underground and other specified installations.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.Single-core wires are also called monolithic wires,
while multi-core wires are flexible wires.Wires usually have a single conductor covered with an insulating layer.
Cables have several insulated wires, covered with a common sheath.
Conductor properties of wires:
The resistance of copper conductors is lower (0.017Ω) than that of aluminum (0.028Ω),
but copper has better conductivity.
Copper has better electrical and thermal conductivity than aluminum.
Copper wires are more flexible, more resistant to corrosion, and more durable.
Aluminum wires quickly oxidize upon contact with air, forming a film that weakens the contact.
Copper wires carry higher currents than aluminum wires.
Copper conductors are denser than aluminum. Therefore, copper wire is heavier.The cross-sectional area of wires is chosen according to the power of specific equipment,
for example: for a 1kW load, a 1.57 mm² cross-sectional area of the conductor is required.
For aluminum wires: 5A per 1mm², and for copper wires: 8A per 1mm².This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Price 48.40 € VAT incl.( 40.00 € VAT excl. )Heating Cable | 12K | 33Ohm/m | 25W/m | 3mm | Carbon Fiber | RedCode: CF-12-R 13 kΩPrice 0.73 € VAT incl.( 0.60 € VAT excl. )