Aluminium power cable | 4x50mm² | AXMK | Class 2 | 1m | Black
Code: AXMK 4x50Aluminium power cable AXMK 4×50 mm², designed for fixed 0.6/1 kV power transmission and distribution installations. The cable features Class 2 aluminium conductors, XLPE insulation and a black UV-resistant PVC sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits and concrete. Maximum operating temperature – 90 °C.
-
Aluminium Power Cable | 4x50mm² | AXMK | 0.6/1kV | 1m Aluminium Power Cable | 4x50mm² | AXMK | 0.6/1kV | 1m
Aluminium power cable 4x50mm² – is a power cable designed for electrical power transmission, featuring aluminium conductors, XLPE insulation and a black PVC outer sheath. The cable is suitable for fixed electrical installations in various environmental conditions, including outdoor installation, underground laying, dry, damp and wet rooms, cable ducts, conduits and direct installation in concrete. The black outer sheath is resistant to UV radiation.
Aluminium power cable for fixed electrical installationsThe cable is designed for electrical networks with a rated voltage of 600/1000V. Four aluminium conductors with a cross-section of 50mm² are suitable for electrical power transmission and distribution circuits. XLPE insulation allows the cable to operate at a maximum working temperature of up to 90°C, while the PVC sheath provides mechanical protection and protection against environmental influences.
4x50mm²Number and cross-section of conductors600/1000VRated voltage90°CMax. operating temperatureClass 2Conductor classConstruction and materials
Construction component Material / Parameter Purpose Conductor Aluminium For electrical power transmission. Conductor class Class 2 Designed for fixed cable installation in electrical systems. Insulation XLPE Electrical insulation of conductors and resistance to higher operating temperatures. Outer sheath PVC Protects the internal cable construction against external environmental influences. Sheath colour Black Suitable for outdoor installation; the sheath is resistant to UV radiation. Installation options
- Outdoor installation
- Underground laying
- Dry rooms
- Damp rooms
- Direct installation in concrete
- Cable ducts
- Protective conduits
UV resistanceThe cable's black PVC outer sheath is resistant to UV radiation, allowing the cable to be used in outdoor electrical installations where it may be exposed to direct sunlight.
XLPE insulationXLPE is used for conductor insulation. This insulating material is suitable for power cables and allows the cable to operate at a maximum working temperature of up to 90°C.
Technical specifications
Cable type AXMK Cable application Aluminium power cable Number of conductors 4 Conductor cross-section 50mm² Conductor Aluminium Conductor class Class 2 Rated voltage 600/1000V Insulation XLPE Outer sheath PVC Colour Black Maximum operating temperature 90°C UV resistance Yes Advantages / Benefits
- 4x50mm² aluminium conductors are suitable for fixed electrical power transmission and distribution lines.
- Aluminium conductors help reduce cable weight and material cost compared with copper cables of the same cross-section.
- XLPE conductor insulation is designed for operation at temperatures up to 90°C.
- PVC outer sheath protects the cable construction against environmental influences.
- Can be installed outdoors, underground and in dry, damp and wet rooms.
- Suitable for installation in cable ducts and conduits.
- Can be installed directly in concrete.
- UV resistance allows the cable to be used in outdoor installations.
Disadvantages / Limitations
- Aluminium conductor: terminals, cable lugs and appropriate connection methods suitable for aluminium conductors must be used during installation.
- Class 2 conductor: the cable is intended for fixed installation and is not designed for continuous flexing or moving connections.
- Fixed power cable: the installation method, cable protection and permissible load must be selected according to the conditions of the specific installation.
What is it suitable for? (Applications)
- Industrial electrical power distribution systems
- Electrical service entrances and distribution lines
- Connection of electrical panels and distribution equipment
- Outdoor electrical installations
- Underground cable laying
- Dry, damp and wet rooms
- Cable ducts and protective conduits
- Fixed 0.6/1kV electrical installations
What is it not suitable for?
- Moving or continuously flexed electrical connections
- Installations requiring a flexible fine-stranded conductor
- Circuits with a rated voltage exceeding the cable's 600/1000V rating
- Connection to terminals not designed for aluminium conductors
Practical example
At an electrical installation site, a fixed power supply line needs to be installed between the main electrical panel and another distribution point. A 4x50mm² aluminium power cable with a rated voltage of 600/1000V is used for this purpose. Part of the cable may be laid underground, while another section is routed through cable ducts or conduits inside the building. XLPE insulation and the PVC outer sheath allow the cable to be used under various environmental conditions, while the UV-resistant black sheath also makes it suitable for outdoor sections of the installation.
Frequently Asked Questions (FAQ)
What type of conductor does this cable use?The cable conductors are made of aluminium. The cable has four conductors with a cross-section of 50mm².
What is the rated voltage of the cable?The rated voltage of the cable is 600/1000V.
Can the cable be laid underground?Yes. The cable is suitable for underground installation.
Is the cable suitable for outdoor installation?Yes. The cable can be used outdoors, and its black outer sheath is resistant to UV radiation.
Can the cable be installed in damp and wet rooms?Yes. The cable is suitable for dry, damp and wet rooms.
Can the cable be installed directly in concrete?Yes. According to the provided information, the cable can be installed directly in concrete.
What is the maximum operating temperature of the cable?The specified maximum operating temperature is 90°C.
What insulation and outer sheath does the cable use?The conductor insulation is XLPE, while the cable outer sheath is PVC.
Important installation noteFor connecting aluminium conductors, use only terminals, cable lugs and other connection equipment suitable for aluminium or Al/Cu connections. Cable cross-section, protective devices, installation method and permissible load must be selected according to the specific electrical installation design, installation conditions and applicable electrical safety requirements.
Aluminium power cable 4x50mm² – a practical solution for fixed 600/1000V electrical power transmission and distribution lines, suitable for outdoor installation, underground laying, various indoor environments, cable ducts, conduits and concrete.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.Single-core wires are also called monolithic wires,
while multi-core wires are flexible wires.Wires usually have a single conductor covered with an insulating layer.
Cables have several insulated wires, covered with a common sheath.
Conductor properties of wires:
The resistance of copper conductors is lower (0.017Ω) than that of aluminum (0.028Ω),
but copper has better conductivity.
Copper has better electrical and thermal conductivity than aluminum.
Copper wires are more flexible, more resistant to corrosion, and more durable.
Aluminum wires quickly oxidize upon contact with air, forming a film that weakens the contact.
Copper wires carry higher currents than aluminum wires.
Copper conductors are denser than aluminum. Therefore, copper wire is heavier.The cross-sectional area of wires is chosen according to the power of specific equipment,
for example: for a 1kW load, a 1.57 mm² cross-sectional area of the conductor is required.
For aluminum wires: 5A per 1mm², and for copper wires: 8A per 1mm².This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Price 48.40 € VAT incl.( 40.00 € VAT excl. )Heating Cable | 12K | 33Ohm/m | 25W/m | 3mm | Carbon Fiber | RedCode: CF-12-R 13 kΩPrice 0.73 € VAT incl.( 0.60 € VAT excl. )