Products catalog

  • Automatic transfer switch ATS | 4P | 63 A | 230/400 V | panel-mounted | EL-ATS-63/4P

    Code: EL-ATS-63/4P
    Price 110.96 € VAT incl.
    ( 91.70 € VAT excl. )
    Buy more, pay less
    10+ pcs.  – 71.67 € for pcs. -35%

    Panel-mounted 4-pole 63 A automatic transfer switch for three-phase sites. When the mains fails, the load moves to the generator and back when the mains returns. The neutral is switched too. Automatic / manual mode, 230/400 V, 50/60 Hz.

  • Automatic transfer switch ATS | 4P | 63 A | 230/400 V | panel-mounted | EL-ATS-63/4P

    A panel-mounted 4-pole automatic transfer switch that switches a three-phase load between the mains and a backup source such as a generator. All four poles – L1, L2, L3 and N – are switched, so the mains and the backup source are never connected to each other.

    Key point:
    A solution for a three-phase site with a supply of up to 63 A, where the load must move to the generator without manual work when the mains fails. Automatic or manual mode can be selected – useful when testing the generator or working in the switchboard.
    Poles
    4P (L1, L2, L3, N)
    Rated current
    63 A
    Voltage
    230/400 V AC, 50/60 Hz
    Modes
    automatic / manual

    How it works

    The switch is installed in the switchboard after the main supply: one input side is connected to the mains, the other to the backup source, and the output to the load or a backup sub-board.

    In automatic mode the device monitors the voltage of the main source. When the mains fails, the load is switched to the backup source, and back again when the mains returns. In manual mode the source is selected by hand.

    Because all four poles are switched, the neutral is switched together with the phases: each source works with its own N–PE point, and residual current devices operate correctly.

    Why choose EL-ATS-63/4P?
    One device replaces two interlocked contactors and a separate control circuit – fewer wires, fewer installation mistakes.

    Technical specifications

    Product typeAutomatic transfer switch (ATS), panel-mounted
    CodeEL-ATS-63/4P
    Number of poles4P
    Rated current63 A
    Rated voltage230/400 V AC (220/380 V)
    Frequency50/60 Hz
    Operating modesAutomatic / manual
    MountingOn a mounting plate in the switchboard
    Dimensions105 × 215 × 90 mm
    HousingHeat-resistant plastic

    Main functions

    • Automatic transfer – when the mains fails, the load moves to the backup source without anyone on site.
    • Return to mains – when the mains returns, the load is switched back.
    • 4-pole switching – the neutral is switched together with the phases, RCDs work correctly.
    • Manual mode – convenient for testing the generator or carrying out maintenance.
    • Sources never connected together – only one source is connected to the load at any time.

    Where is it used?

    • Houses and country homes with a three-phase supply and a three-phase generator
    • Farms: cold rooms, water pumps, ventilation
    • Workshops and small production facilities
    • Shops, offices, small commercial premises
    • Boiler rooms and heating substations
    • Backup sub-boards with critical circuits

    Use by need

    For a homeowner.
    When the power goes out, the boiler, pump and fridges switch to the generator without a trip to the switchboard.
    For a farmer.
    Livestock watering and ventilation keep running even during a longer grid outage.
    For an electrician.
    A ready-made 4P switch instead of interlocked contactors – faster and neater switchboard assembly.

    Practical example

    If a country home has a 3×32 A three-phase supply and a three-phase generator, the EL-ATS-63/4P is installed after the main circuit breaker: when the mains fails, the load moves to the generator, and back when the mains returns. If the generator has no automatic start, it must be started manually or an ATS controller with a start contact must be added.

    Pros

    • All 4 poles are switched
    • Automatic and manual mode
    • Compact housing – 215 × 90 mm
    • Suitable for 50 and 60 Hz sources
    • Simpler wiring than with contactors

    Cons / limitations

    • Maximum current 63 A – for a larger supply choose a 100–125 A ATS
    • Does not start the generator itself – requires a generator with automatic start or an ATS controller
    • Plate-mounted, not for DIN rail
    • No short-circuit protection is specified for the device – circuit breakers are required upstream

    Safety and installation notes

    • Before any work, disconnect both the mains and the generator.
    • Install circuit breakers on both input sides, sized to the cable cross-section and source current.
    • Make the generator N–PE connection according to the manufacturer’s instructions and the site earthing system.
    • Never connect a generator through a socket outlet – only through a transfer switch.
    • Installation must be carried out by a qualified electrician.

    Quick selection guide

    4P
    63 A
    230/400 V
    Panel-mounted
    Suitable when you need to:
    • switch a three-phase load between the mains and a generator;
    • the main circuit breaker is no larger than 63 A;
    • switch the neutral as well.
    Check before use:
    • supply current and number of phases;
    • whether the generator has automatic start;
    • whether there is room in the switchboard for a 215 × 90 mm plate.
    Important: An ATS does not replace circuit breakers and does not protect against overload or short circuit.

    FAQ

    Does this ATS start the generator?
    No, it switches the load between available voltages; automatic start requires an ATS controller or a generator with its own start module.
    Is it suitable for a single-phase house?
    For a single-phase supply a 2P ATS is a better fit; 4P is intended for a three-phase supply with neutral.
    What generator power do I need?
    The generator is sized to what you will power in backup mode, and the ATS to the supply current.
    Is protection needed before the ATS?
    Yes, install circuit breakers on both input sides.
    Can it be switched manually?
    Yes, the device has a manual mode.
    Can I install it myself?
    The ATS is connected into the main supply circuit, so it must be installed by a qualified electrician.

    Automatic transfer switch ATS | 4P | 63 A | EL-ATS-63/4P

    A panel-mounted 4P 63 A ATS for three-phase sites: automatically transfers the load between the mains and a generator and switches the neutral together with the phases.

    Published: 2026-11-12 · Data verified against supplier specification: 2026-11-12

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Interface relay | 2CO | 8 A | coil 24 V DC | plug-in / PCB | Finder 40.52.9.024.0000
    Code: 40.52.9.024.0000

    Finder 40.52.9.024.0000 – interface relay with 2CO contacts (8 A) and 24 V DC coil. For control signal isolation, contact multiplication and control of contactor and valve coils in automation panels.

    Price 2.96 € VAT incl.
    ( 2.45 € VAT excl. )
    Network plug | RJ45 connector (8P8C) | for UTP CAT 6e cable | unshielded | through-plug | transparent
    Code: WT117

    This RJ45 Cat.6 UTP modular plug is a high-quality 8P8C unshielded network connector type, designed for Cat.6 UTP (Unshielded Twisted Pair) cables. The special straight-through design makes cable termination easier and more convenient, as the wires can be threaded through the plug, allowing a visual check of the wire arrangement before crimping the connector.

    Price 0.20 € VAT incl.
    ( 0.17 € VAT excl. )
    Solar PV cable | H1Z2Z2-K | 1x4 mm² | black | 1.5 kV DC | EN 50618 | Dca | IEMMEQU HAR
    Code: H1Z2Z2K

    The cable is designed for connecting photovoltaic (solar energy) systems and interconnecting solar modules. This cable offers excellent resistance to ultraviolet (UV) rays, ozone, atmospheric effects, and temperature fluctuations. A durable and flexible single-core copper cable with double insulation ensures long service life and safe use even in the most challenging outdoor conditions. Suitable for installation both indoors and outdoors.

    Price 0.98 € VAT incl.
    ( 0.81 € VAT excl. )
    Interface relay | 2CO | 8 A | coil 24 V DC | plug-in | Schneider Electric RSB2A080BD
    Code: RSB 2A080BD

    Schneider Electric RSB2A080BD – interface relay with 2CO contacts (8 A) and 24 V DC coil. For control signal isolation, contact multiplication and control of contactor and valve coils in automation panels.

    Price 2.94 € VAT incl.
    ( 2.43 € VAT excl. )
    Interface relay | 2CO | 10 A | coil 24 V DC | plug-in | OMRON LY2N 24 V DC
    Code: LY2N 24VDC

    OMRON LY2N 24 V DC – interface relay with 2CO contacts (10 A) and 24 V DC coil. For control signal isolation, contact multiplication and control of contactor and valve coils in automation panels.

    Price 6.05 € VAT incl.
    ( 5.00 € VAT excl. )
    Relay socket | Finder 55.32 / 55.34 | 10 A | 250 V | DIN 35 mm | Finder 94.04SPA
    Code: 94.04SPA

    Finder 94.04SPA – socket for Finder 55.32 / 55.34 relays, mounted on DIN rail. Screw terminals; the relay can be replaced without disconnecting wires.

    Price 3.03 € VAT incl.
    ( 2.50 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information