Products catalog

  • Axial exhaust fan with backdraft damper | D100 | 100 m³/h | 220V | 145x130x49 mm | short flange | plastic | white | IPX4

    Code: ESLP24389

    Axial exhaust fan with backdraft damper, Ø100 mm: 100 m³/h, 40 Pa, 35 dB(A), 14 W, IPX4. Backdraft damper blocks back-draught. Wall or ceiling mounting. Short 49 mm flange and removable wave panel.

  • Axial exhaust fan with backdraft damper | D100 | 100 m³/h | 220V | 145x130x49 mm | short flange | plastic | white | IPX4

    Axial exhaust fan with backdraft damper for a Ø100 mm duct or wall opening – for removing moisture, odours and stale air from a bathroom, toilet, kitchen or storeroom. The short 49 mm flange allows installation in a shallow opening, and the wave-design front panel can be removed without screws.

    Key point:
    Rated capacity 100 m³/h, static pressure 40 Pa, noise 35 dB(A), power 14 W. The backdraft damper closes the duct when the fan stops, so cold air and odours do not come back from the shaft. The short flange solves the problem when wall or duct depth is limited.
    Mounting diameter
    Ø100 mm
    Capacity
    100 m³/h
    Noise
    35 dB(A)
    Feature
    backdraft damper

    How it works

    The fan is inserted into a Ø100 mm duct or wall opening and mounted on a wall or ceiling. Supply: 220–240 V, 50 Hz. The short 49 mm flange allows installation in a shallow opening without deepening the wall, and the rib-reinforced housing also suits uneven surfaces such as relief tiles. The fan is switched by an external switch – a separate one or together with the lighting.

    When switched on, the impeller extracts air into the ventilation duct: rated capacity 100 m³/h, static pressure 40 Pa, power 14 W, current 0.06 A. The backdraft damper closes automatically when the fan is off and keeps cold air, odours and dust from coming back into the room.

    The result is a room that dries faster, a lower risk of condensation and mould, and a duct that stays closed while the fan is off.

    Why choose ESLP24389?
    The backdraft damper blocks back-draught from the duct – relevant in apartment blocks with a shared shaft and in the cold season. The wave panel can be removed without screws, so cleaning is easy.

    Technical specifications

    Product type Axial exhaust fan with backdraft damper
    Product code ESLP24389
    Duct diameter Ø100 mm
    Air flow 100 m³/h
    Static pressure 40 Pa
    Noise level 35 dB(A)
    Power 14 W
    Current consumption 0.06 A
    Supply 220–240 V / 50 Hz
    Protection rating IPX4
    Dimensions 145×130×49 mm
    Flange length 49 mm (short)
    Housing plastic, white
    Housing design rib-reinforced
    Front panel wave design, removable without screws
    Control by an external switch
    Backdraft damper built-in, closes when the fan stops
    Mounting wall or ceiling

    Main functions

    • Backdraft damper – closes when the fan stops, so cold air, odours and dust do not come back into the room.
    • Short 49 mm flange – installs where the opening depth is limited.
    • Wave panel without screws – removed for cleaning without tools.
    • 100 m³/h capacity – sufficient for air exchange in a bathroom, toilet or storeroom.
    • IPX4 protection – protection against water splashes from any direction (protection against solids not specified).
    • Wall or ceiling mounting – flexible fit to the room.
    • 14 W power – low running costs.

    How the models in this series differ

    • ESLP24388 – basic model · 100 m³/h
    • ESLP24389 – backdraft damper · 100 m³/h – this model
    • ESLP24390 – damper + pull-cord switch · 100 m³/h
    • ESLP24391 – damper + timer · 100 m³/h
    • ESLP24392 – damper + timer + humidity sensor · 100 m³/h

    Where is it used?

    • Bathrooms and showers
    • Toilets
    • Kitchens
    • Storerooms and walk-in wardrobes
    • Basements and utility rooms
    • Sanitary rooms in offices and small commercial premises
    • Renovated homes with shallow ventilation openings

    Use by need

    For apartment block residents.
    The backdraft damper keeps odours and cold air from the shared shaft out.
    For electricians.
    Short 49 mm flange – no need to deepen the wall opening, and the housing also fits on relief tiles.
    For designers.
    For renovation projects with limited mounting depth and textured finishes – 100 m³/h, 40 Pa.

    Practical use

    If a bathroom measures 2.0 × 2.5 m with a 2.5 m ceiling (about 12.5 m³), the rated flow of 100 m³/h would theoretically change the air about 8 times per hour; in practice the flow will be lower due to duct length, bends and grilles. In an apartment block the backdraft damper will keep the neighbours' odours from the shared shaft out while the fan is off.

    Pros

    • Built-in backdraft damper
    • Short 49 mm flange for shallow openings
    • Panel removable without screws
    • Rib-reinforced housing
    • Noise 35 dB(A)
    • Low consumption – 14 W
    • Wall or ceiling mounting

    Cons / limitations

    • No timer or humidity sensor – switch-controlled; with timer: ESLP24391
    • 35 dB(A) – more audible than the 25–30 dB(A) compact ESLP189xx series models
    • IPX4 – splash protection, not protection against water jets or immersion
    • The rated 100 m³/h flow is given without duct resistance; in a long duct it is lower
    • No heat recovery – room air is exhausted

    Safety and installation notes

    • Disconnect the power before installation and make sure the circuit is de-energised.
    • Protect the bathroom circuit with a 30 mA residual current device (RCD).
    • IPX4 means splash protection: under HD 60364-7-701, at least IPX4 is required in zones 1 and 2, and installation in zone 0 (inside a bath or shower tray) is not allowed.
    • Make sure the backdraft damper opens and closes freely – the duct or sealant must not press on it.
    • Mains installation must be carried out by a qualified electrician.

    Quick selection guide

    Ø100 mm
    100 m³/h
    35 dB(A)
    14 W
    IPX4
    backdraft damper
    Flange 49 mm
    Suitable when you need:
    • To extract moisture and odours from a bathroom or toilet
    • To stop cold air and odours coming back from the duct
    • To install in a shallow opening (49 mm flange)
    Check before use:
    • Whether the duct or opening diameter is Ø100 mm
    • Whether there is room for the 145×130×49 mm housing
    • Whether the opening is deep enough for the 49 mm flange
    • Whether a 220–240 V supply is available at the opening
    • Whether the room has an air inlet path (gap under the door or a grille)
    Important reminder: The fan does not replace continuous mechanical ventilation or a heat recovery unit – it extracts air only while running.

    FAQ

    How is the fan switched on?
    By an external switch – a separate one or together with the lighting.
    Does the fan have a backdraft damper?
    Yes, the built-in damper closes when the fan stops.
    What duct diameter does ESLP24389 fit?
    A Ø100 mm duct or wall opening.
    Can it be mounted in the ceiling?
    Yes, the fan is mounted on a wall or ceiling.
    Is it suitable for a bathroom?
    Yes, the housing is IPX4, but do not install it in zone 0 and protect the circuit with a 30 mA RCD.
    What is the short flange for?
    The 49 mm flange allows the fan to be installed where the opening or duct depth is limited.

    Axial exhaust fan with backdraft damper | D100 | 100 m³/h | 220V | 145x130x49 mm | short flange | plastic | white | IPX4

    ESLP24389 is a Ø100 mm axial exhaust fan with backdraft damper: 100 m³/h, 40 Pa, 35 dB(A), 14 W, IPX4. Short 49 mm flange and removable wave panel – for shallow mounting openings.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Shut-off damper for round air duct | for ventilation | air handling systems | D100 | silver | galvanized steel | 100USO
    Code: 04963

    Round duct shut-off damper, designed to shut off, restrict, or regulate airflow in round air ducts. The damper is used in supply, exhaust, or recirculation air systems where simple and efficient control of air movement within premises is required.

    Due to its galvanized steel construction, the product is resistant to corrosion, durable, and suitable for use in residential, commercial, and technical ventilation systems. Manual operation allows easy airflow adjustment without the need for an additional electric actuator or automation system. 

    Price 6.50 € VAT incl.
    ( 5.37 € VAT excl. )
    Flexible aluminum air duct | for ventilation | ventilation systems | D100mm | 3m | white | LAO100B
    Code: 23033

    Flexible aluminium air duct - a reliable and universal solution for professional and residential ventilation systems. Designed to connect ventilation elements, fans, heat recovery components or other air distribution units.

    Due to its low weight, high flexibility and resistance to high temperatures, the duct ensures quick installation, tightness and long-term operation even in more demanding conditions. The white surface blends aesthetically in technical and visible installation areas. 

    Price 7.20 € VAT incl.
    ( 5.95 € VAT excl. )
    Duct centrifugal fan | D125 | 370 m³/h | 52 W | 230 V | 310 Pa | plastic housing | white | 15622
    Code: 15622

    Duct centrifugal fan 15622: D125, up to 370 m³/h, 310 Pa, 52 W, 230 V, plastic housing.

    Price 93.17 € VAT incl.
    ( 77.00 € VAT excl. )
    Supply air ventilation damper in the wall | with filter | mineral wool thermal insulation with foil | D125 | 0,45m | white | 12,5TOV045-01
    Code: 23041

    Wall supply air valve Ø125 mm / 450 mm with filter, non-return valve and foil-faced mineral wool insulation. Restores fresh air supply in apartments, houses and offices, dampens street noise, while the foil protects the wool from moisture and dust.

    Price 31.45 € VAT incl.
    ( 25.99 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information