Products catalog

  • Axial exhaust fan with backdraft damper and pull-cord switch | D150 | 210 m³/h | 230V | 211x195x81 mm | plastic | white | IPX4

    Code: ESLP22949

    Ø150 mm axial exhaust fan with automatic backdraft damper and pull-cord switch: 210 m³/h, 40 dB(A), 10 W, IPX4. Mounts in a wall, ceiling or duct and is switched directly at the unit.

  • Axial exhaust fan with backdraft damper and pull-cord switch | D150 | 210 m³/h | 230V | 211x195x81 mm | plastic | white | IPX4

    Axial exhaust fan for a Ø150 mm opening with a built-in backdraft damper and pull-cord switch. Designed to remove moisture and odours from a bathroom, toilet, storeroom or other small room when you want to switch the fan on directly at the unit – without a separate wall switch.

    Key point:
    The pull-cord switch simplifies the installation: a 230 V supply to the fan is enough, and it is switched on by pulling the cord. When the fan stops, the backdraft damper closes the duct, so cold air and odours are not drawn in from the shaft. Rated capacity is 210 m³/h, noise level 40 dB(A).
    Mounting diameter
    Ø150 mm
    Capacity
    210 m³/h
    Noise
    40 dB(A)
    Power
    10 W

    How it works

    The fan is inserted into a Ø150 mm duct or wall opening and fixed with a flange fixing ring and mounting brackets. Supply is 230 V AC and control is by the built-in pull-cord switch, so no separate wall switch is needed.

    When switched on, the impeller extracts air into the ventilation duct (up to 210 m³/h in free-air conditions, max. pressure 40 Pa). The air flow opens the backdraft damper; when the fan stops, the damper closes and blocks back-draught.

    The result is a bathroom that dries faster, a lower risk of mould and a room that does not take in cold air from the shaft while the fan is off.

    Why choose ESLP22949?
    One unit does three jobs: it extracts air, it is switched by a pull cord with no extra wiring, and it closes the duct when idle. This is convenient in renovation work when you do not want to install a new wall switch.

    Technical specifications

    Product type Axial exhaust fan with backdraft damper and pull-cord switch
    Product code ESLP22949
    Mounting diameter Ø150 mm
    Supply voltage 230 V AC
    Power 10 W
    Air flow (capacity) 210 m³/h
    Maximum pressure 40 Pa
    Noise level 40 dB(A)
    Dimensions 211×195×81 mm
    Protection rating IPX4
    Control built-in pull-cord switch
    Backdraft damper built-in, closes when the fan stops
    Housing moisture-resistant plastic, white
    Mounting wall, ceiling or duct; a flange fixing ring and mounting brackets
    Front cover removable

    Main functions

    • Pull-cord switch – switched on and off directly at the fan, no additional switch or cable to it needed.
    • Automatic backdraft damper – the duct closes when the fan stops, keeping cold air and odours out of the room.
    • 210 m³/h capacity – sufficient for air exchange in a small bathroom, toilet or storeroom.
    • 40 dB(A) noise level – suitable for living spaces.
    • IPX4 housing – protected against water splashes, suitable for damp rooms.
    • Versatile mounting – in a wall, ceiling or directly in a duct.
    • Removable front cover – easy to dust and to inspect the impeller.

    How the models in this series differ

    • D100 · 105 m³/h – 32 Pa · 25 dB(A) · 8.4 W · 152×141×70 mm
    • D120 · 160 m³/h – 35 Pa · 30 dB(A) · 10 W · 182×168×69 mm
    • D120 · 190 m³/h – 40 Pa · 30 dB(A) · 10 W · 182×168×69 mm
    • D150 · 210 m³/h – 40 Pa · 40 dB(A) · 10 W · 211×195×81 mm – this model

    Where is it used?

    • Bathrooms and showers
    • Toilets
    • Storerooms and walk-in wardrobes
    • Basements and utility rooms
    • Laundry and drying rooms
    • Small sanitary rooms in offices and workshops
    • Country houses and seasonal homes

    Use by need

    For apartment owners.
    Replaces an old fan without a new wall switch – a power supply at the opening is enough.
    For electricians.
    Standard Ø150 mm diameter, 230 V connection and pull-cord control – less wiring work.
    For country house owners.
    The backdraft damper keeps cold air in the duct when the house is unheated or the fan is off.

    Practical use

    If a bathroom measures 2.0 × 2.5 m with a 2.5 m ceiling (about 12.5 m³), the rated flow of 210 m³/h would theoretically change the air about 17 times per hour. In practice the flow will be lower due to duct length, bends and grilles, so for a long or winding duct a higher-capacity model of this series is worth choosing.

    Pros

    • Built-in automatic backdraft damper
    • Pull-cord control – no separate switch needed
    • Quiet operation – 40 dB(A)
    • Low consumption – 10 W
    • Wall, ceiling or duct mounting
    • IPX4 splash protection

    Cons / limitations

    • No timer or humidity sensor – switched on and off manually
    • The rated 210 m³/h flow is given without duct resistance; in a long duct it is lower
    • Designed for small and medium rooms, not for central ventilation systems
    • No heat recovery – room air is exhausted

    Safety and installation notes

    • Disconnect the power before installation and make sure the circuit is de-energised.
    • Protect the bathroom circuit with a 30 mA residual current device (RCD).
    • IPX4 means splash protection, not immersion: do not install directly above a bath or shower tray (zone 0) and follow the zone requirements of HD 60364-7-701.
    • Make sure the backdraft damper opens and closes freely – the duct or sealant must not press on it.
    • The cord must hang freely and must not wrap around the housing.
    • Mains installation must be carried out by a qualified electrician.

    Quick selection guide

    Ø150 mm
    210 m³/h
    40 dB(A)
    10 W
    IPX4
    Pull-cord switch
    Suitable when you need:
    • To extract moisture from a bathroom or toilet
    • To switch the fan without a separate wall switch
    • To stop cold air coming back from the duct
    Check before use:
    • Whether the duct or opening diameter is Ø150 mm
    • Whether there is room for the 211×195×81 mm housing
    • Whether a 230 V supply is available at the opening
    • Whether the room has an air inlet path (gap under the door or a grille)
    Important reminder: The fan does not replace continuous mechanical ventilation or a heat recovery unit – it extracts air only while switched on.

    FAQ

    Do I need a separate wall switch?
    No, the fan is switched on and off with the built-in pull-cord switch.
    What is the backdraft damper for?
    When the fan stops it closes the duct so that cold air and odours do not enter the room.
    What duct diameter does ESLP22949 fit?
    A Ø150 mm duct or wall opening.
    Can it be mounted in the ceiling?
    Yes, the fan can be mounted in a wall, ceiling or duct.
    Does it have a timer or humidity sensor?
    No, this model is controlled only by the pull-cord switch.
    Is it suitable for a bathroom?
    Yes, the housing is IPX4, but install it outside zone 0 and protect the circuit with a 30 mA RCD.

    Axial exhaust fan with backdraft damper and pull-cord switch | D150 | 210 m³/h | 230V | 211x195x81 mm | plastic | white | IPX4

    ESLP22949 is a Ø150 mm axial exhaust fan with an automatic backdraft damper and pull-cord switch: 210 m³/h, 40 dB(A), 10 W, IPX4. Designed for bathrooms, toilets and other small rooms where the fan is to be controlled directly at the unit.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Flexible aluminum air duct | for ventilation | ventilation systems | D100mm | 3m | white | LAO100B
    Code: 23033

    Flexible aluminium air duct - a reliable and universal solution for professional and residential ventilation systems. Designed to connect ventilation elements, fans, heat recovery components or other air distribution units.

    Due to its low weight, high flexibility and resistance to high temperatures, the duct ensures quick installation, tightness and long-term operation even in more demanding conditions. The white surface blends aesthetically in technical and visible installation areas. 

    Price 7.20 € VAT incl.
    ( 5.95 € VAT excl. )
    Duct centrifugal fan | D125 | 370 m³/h | 52 W | 230 V | 310 Pa | plastic housing | white | 15622
    Code: 15622

    Duct centrifugal fan 15622: D125, up to 370 m³/h, 310 Pa, 52 W, 230 V, plastic housing.

    Price 93.17 € VAT incl.
    ( 77.00 € VAT excl. )
    Supply air ventilation damper in the wall | with filter | mineral wool thermal insulation with foil | D125 | 0,45m | white | 12,5TOV045-01
    Code: 23041

    Wall supply air valve Ø125 mm / 450 mm with filter, non-return valve and foil-faced mineral wool insulation. Restores fresh air supply in apartments, houses and offices, dampens street noise, while the foil protects the wool from moisture and dust.

    Price 31.45 € VAT incl.
    ( 25.99 € VAT excl. )
    Shut-off damper for round air duct | for ventilation | air handling systems | D100 | silver | galvanized steel | 100USO
    Code: 04963

    Round duct shut-off damper, designed to shut off, restrict, or regulate airflow in round air ducts. The damper is used in supply, exhaust, or recirculation air systems where simple and efficient control of air movement within premises is required.

    Due to its galvanized steel construction, the product is resistant to corrosion, durable, and suitable for use in residential, commercial, and technical ventilation systems. Manual operation allows easy airflow adjustment without the need for an additional electric actuator or automation system. 

    Price 6.50 € VAT incl.
    ( 5.37 € VAT excl. )
  • privacy policy