Dosimeter-radiometer with temperature sensor | 0…65000 μR/h | −40…+70 °C | 1-Wire | for D105 pulse analyzer | smart-MAIC | DR-20
Code: DR-20Dosimeter-radiometer for remote real-time monitoring of gamma background level, accumulated dose and ambient temperature. Connects to the D105 1-Wire input (not RS485) and is powered with 5 V from the D105. Range 0…65000 μR/h, data refreshed every 10 s.
-
Dosimeter-radiometer with temperature sensor | 0…65000 μR/h | −40…+70 °C | 1-Wire | for D105 pulse analyzer | smart-MAIC | DR-20
The DR-20 is a dosimeter-radiometer with a built-in temperature sensor, designed for continuous radiation background monitoring via the smart-MAIC D105 pulse analyzer. According to the manufacturer, it measures gamma background level, accumulated dose and ambient temperature in real time.
Key point:
A handheld dosimeter shows the situation only at the moment you measure. The DR-20 measures continuously, and the D105 sends the data, refreshed every 10 s, to the cloud – creating a continuous background history and allowing a notification when the level rises. It connects to the 1-Wire input and is powered from the D105, so no additional power supply is needed.Range
0…65000 μR/hTemperature
−40…+70 °CRefresh
every 10 sInterface to D105
1-Wire (not RS485)Connection to D105 and integration
- 1-Wire input (terminal 4) – The yellow wire (1-Wire) connects to D105 terminal 4. The DR-20 occupies the entire 1-Wire input – it cannot be combined with DS18b20, DHT22 or D280.
- Power (terminals 6 and 1) – Red wire – terminal 6 (+5 V DC from the D105), white – terminal 1 (GND). The green wire (TX UART) is not used with the D105 – it is intended for third-party devices (UART 9600 baud, 5 V).
- Configuration and data – In the D105 “Counter config” settings select the radiation sensor, wait 15 s and press “Refresh” in the “Current Data” window. T1 – temperature, T2 – μR/h, T3 – pulses per minute.
How it works
The device is fixed at the monitored location – indoors, under a canopy or in an outdoor enclosure – and connected to the D105 with three wires (5 V, GND, 1-Wire). The green UART wire is insulated.
The DR-20 registers ionising radiation particles, counts them per minute, converts the count into exposure dose rate (μR/h) and measures temperature at the same time. Data is refreshed every 10 s.
In the smart-MAIC cloud you see radiation background and temperature curves and history, and can set a notification or D105 relay action when the background exceeds your threshold. Data is also available via API and MQTT.
Why choose the DR-20?
It turns the D105 into a permanent radiation background monitoring station: no separate power supply, with cloud history and notifications. It is a simple way to have your own objective background data instead of occasional measurements.Technical specifications
Product type Dosimeter-radiometer with temperature sensor Manufacturer / model smart-MAIC / DR-20 Radiation background range 0…65000 μR/h Temperature range −40…+70 °C Data refresh every 10 s Output signal D105 1-Wire / TX UART (9600 baud, 5 V) Power supply 5 V DC (from D105 terminal 6) Operating temperature −40…+70 °C Operating humidity 0…95 % RH Dimensions (L × H × W) 125 × 20 × 85 mm Weight 120 g Connection to D105 1-Wire input, terminal 4; GND – 1, +5 V – 6; green TX wire not used Data channels T1 – °C, T2 – μR/h, T3 – pulses/min Key functions
- Continuous gamma background measurement – a continuous history, not occasional readings.
- Wide range 0…65000 μR/h – from natural background to high levels.
- Temperature in the same device – an extra parameter without a separate sensor.
- Refresh every 10 s – fast response to changes.
- Notifications and relay – an alert or equipment switching when the threshold is exceeded.
- UART output – can be connected to third-party controllers without a D105.
How does it differ from similar products?
- DS18b20 – Measures temperature only, but with ±0.5 °C accuracy and up to 5 pcs on one input; in the DR-20 temperature is an extra parameter alongside radiation.
- D280 – Also connects to the 1-Wire input and measures temperature, humidity and pressure; it does not measure radiation. One D105 takes either the D280 or the DR-20.
- D105 Solar – Measures solar irradiance (W/m²) via RS485 – this is light energy, not ionising radiation.
Where is it used?
- Municipal and community environmental monitoring
- Civil protection and emergency preparedness facilities
- School and university physics laboratories
- Scrap metal yards (indicative background monitoring)
- Private houses and country homes
- Weather stations together with other D105 sensors
Use by need
For municipalities and communities.
Continuous, publicly available background data – objective information for residents without manual measurements.For physics teachers.
Real radiation background measurements in the cloud – material for lessons on natural background and its variation.For civil protection specialists.
A notification if the background suddenly rises – a faster decision on whether further checks are needed.Practical use
If you want continuous radiation background data at your site, mount the DR-20 in an outdoor enclosure and connect it to the D105 1-Wire input. Then set a notification in the cloud, for example when the background exceeds 50 μR/h, and you will be alerted if the level rises unexpectedly.Pros
- Continuous gamma background monitoring with history
- Wide range 0…65000 μR/h
- Temperature in the same device
- 5 V power from the D105, no extra unit
- Refresh every 10 s
- Additional UART output for other devices
Cons / limitations
- Occupies the entire D105 1-Wire input – cannot be combined with DS18b20, DHT22 or D280.
- The manufacturer does not state measurement error – this is a monitoring device, not a metrological instrument.
- Designed for gamma background; radon concentration requires a dedicated radon monitor.
- Not compatible with RS485 – connects only via 1-Wire or UART.
Safety and installation notes
- Connect the sensor only with the D105 power switched off.
- Insulate the green TX UART wire – it is not used with the D105.
- Follow the wire colours: red – terminal 6, white – 1, yellow – 4.
- Outdoors, mount in a protective enclosure – operating humidity up to 95 % RH, no direct water.
- Do not move the device often – the history is comparable only at the same location.
Quick selection guide
0…65000 μR/h−40…+70 °C1-Wire, every 10 s5 V from the D105Suitable when you need:- continuous radiation background monitoring
- a notification when the background rises
- background and temperature history in the cloud
Check before use:- that the D105 1-Wire input is free
- that the mounting point is protected from direct water
- that you do not need a metrologically approved instrument
Important reminder: The DR-20 works with the D105 via 1-Wire (not RS485) and is not intended for occupational exposure records – where regulations require personal dosimetry, use certified instruments.FAQ
Which D105 input does the DR-20 connect to?
To the 1-Wire input (terminal 4), not to RS485.What is the green TX UART wire for?
For third-party devices (UART 9600 baud, 5 V); it is not used with the D105.Is a separate power supply needed?
No, the DR-20 is powered with 5 V DC from D105 terminal 6.How to convert μR/h to μSv/h?
Approximately 100 μR/h ≈ 1 μSv/h.Can a DS18b20 be connected at the same time?
No, the DR-20 occupies the entire 1-Wire input.How often is data refreshed?
Every 10 s, and it is sent to the cloud according to the D105 data interval.DR-20 dosimeter-radiometer for the smart-MAIC D105 analyzer
The DR-20 continuously measures gamma background 0…65000 μR/h and temperature −40…+70 °C, connects to the D105 1-Wire input and is powered with 5 V. Background history and notifications in the smart-MAIC cloud.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Carbon dioxide (CO2) sensor | 0…5000 ppm | ±50 ppm | RS485 | for D105 pulse analyzer | smart-MAIC | CO2-5000Code: CO2-5000Price 65.63 € VAT incl.( 54.24 € VAT excl. )Price 115.66 € VAT incl.( 95.59 € VAT excl. )