Products catalog

  • Gel T-branch joint | 1 × 95–240 mm² | branch 1 × 50–120 mm² | without connectors | 0.6/1 kV | 250 × 143 × 46 mm | IP68 | SHARK 435/S | SH1435

    Code: SH1435

    SHARK 435/S (SH1435) is a branch (T) joint pre-filled with silicone gel for single-core 0.6/1 kV cables: main conductor 1 × 95–240 mm², branch 1 × 50–120 mm². Connectors are not included – choose them according to cross-section and conductor material. Housing 250 × 143 × 46 mm, protection IP68 (IPX8).

  • Gel T-branch joint | 1 × 95–240 mm² | branch 1 × 50–120 mm² | without connectors | 0.6/1 kV | 250 × 143 × 46 mm | IP68 | SHARK 435/S | SH1435

    SHARK 435/S (SH1435) is a branch (T) joint pre-filled with silicone gel for single-core 0.6/1 kV cables: main conductor 1 × 95–240 mm², branch 1 × 50–120 mm². Connectors are not included – choose them according to cross-section and conductor material. Housing 250 × 143 × 46 mm, protection IP68 (IPX8).

    Key idea:
    Joints on large single-core cables are common in distribution networks, lighting lines and industry. The gel-filled housing insulates the connector or lug of your choice and seals it against water without resin, while still allowing it to be reopened for inspection.
    Sealing
    IP68 (IPX8)
    Cores
    1 × 95–240 mm²
    Dimensions
    250 × 143 × 46 mm
    Voltage
    0.6/1 kV

    How it works

    The cable sheath and core insulation are stripped to the length given in the instructions, the cores are joined in the terminal block or connector and tightened (with the supplied Allen key where specified).

    The joint is pressed into the gel-filled housing between the internal ribs and the housing is snapped shut. As it closes, the gel is displaced and surrounds the cores and the cable sheath at both ends, forming a tight barrier against water and dirt.

    The result is a double-insulated joint that can be laid directly in the ground, in a duct, overhead or under water. Cable ties through the slots in the housing secure the cables and reduce pull on the joint.

    Why choose SHARK 435/S?
    The joint is ready in a few minutes without mixing resin, waiting for curing or heating. The gel has no shelf life, and the joint can be opened for checks or changes.

    Technical specifications

    Product typePre-filled gel T-branch joint without connectors
    Manufacturer / seriesSHARK (Etelec, Italy)
    ModelSHARK 435/S
    CodeSH1435
    Main cable (cores × cross-section)1 × 95–240 mm²
    Branch1 × 50–120 mm²
    Connectors includedNone – connectors are selected separately; kit contains gel shell, cable ties, instructions
    ConductorsAccording to the chosen connectors
    Rated voltage0.6/1 kV
    Dimensions (L × W × H)250 × 143 × 46 mm
    Degree of protectionIP68 (IPX8)
    Operating temperature−20…+90 °C
    HousingPolypropylene (PP), blue, UV resistant, self-extinguishing (EN 60695-2-11)
    FillingTransparent non-toxic silicone gel
    InstallationDirect burial, underground, overhead, cable ducts, submerged
    StandardsEN 50393, EN 60695-2-11, CEI 20-37/2-1, CEI 20-37/4; RoHS
    Re-enterableYes
    Shelf lifeUnlimited

    Main features

    • Pre-filled with gel – no resin and no curing time.
    • Re-enterable – contacts can be checked and reworked.
    • Transparent silicone gel – you can see that the gel has sealed the cores.
    • Double insulation – gel and housing insulate the joint together.
    • UV-resistant PP housing – suitable outdoors and overhead.
    • Cable tie fixing – less pulling load on the joint.

    Where is it used?

    • Street and area lighting branches to poles or luminaires
    • Underground cable routes between buildings
    • Pumps, wells, fountains, ponds
    • Cable repair after damage during excavation
    • Damp cable ducts and shafts
    • 0.4 kV networks of industrial and infrastructure sites

    Use by need

    For the electrician.
    A quick, sealed joint or branch on site without resin or special tools.
    For the home or country-house owner.
    A reliable buried cable joint to garden lights, gate automation or a pump.
    For the utility engineer / contractor.
    A re-enterable joint that can be inspected without replacing the insulation.

    Practical example

    If a new luminaire has to be fed from an underground lighting line, the main cable is not cut – the branch is connected with a connector, the joint is pressed into the SHARK 435/S gel and the housing is closed. The line stays continuous and the branch is sealed.

    Pros

    • Ready to use – no resin, pouring or heating
    • Sealed against water and dust (IP68 / IPX8)
    • Can be opened for inspection and changes
    • Non-toxic gel with no shelf life
    • Suitable for burial, overhead, ducts and submersion

    Cons / limitations

    • Only for 0.6/1 kV and lower-voltage cables
    • Cable cross-section and number of cores must match the joint size
    • Connectors are not included and must be purchased separately
    • Operating temperature up to +90 °C

    Safety and installation notes

    • Carry out all work with the supply switched off and verified dead.
    • Follow the manufacturer's stripping length – no bare conductor should protrude from the connector.
    • Tighten terminals to the specified torque; a loose contact heats up.
    • After closing, check that the gel has been displaced and surrounds the cable at both ends.
    • Do not use the joint for larger cross-sections or more cores than specified.

    Quick selection guide

    1 × 95–240 mm²
    branch 1 × 50–120 mm²
    without connectors
    0.6/1 kV
    250 × 143 × 46 mm
    IP68
    SHARK 435/S
    SH1435
    Suitable when you need:
    • To join or branch a cable tightly in the ground, outdoors or in water
    • Fast installation without resin or curing time
    • The option of reopening the joint later
    Check before use:
    • Number of cores and cross-section
    • Conductor material (Cu / Al) and connector suitability
    • Cable diameter and joint size
    Important reminder: The joint does not replace overload and short-circuit protection – the line must be protected by a circuit breaker or fuses, and outdoor circuits by an RCD.

    FAQ

    Do I need to add resin or gel?
    No, the joint is already filled with gel and ready to use.
    Can the joint be buried directly in the ground?
    Yes, the manufacturer specifies direct burial, ducts, overhead and submersion.
    Can it be opened later?
    Yes, the housing can be opened, the joint checked and closed again.
    Are connectors included?
    No, the connector or terminal must be chosen separately.
    What voltage is it for?
    For 0.6/1 kV low-voltage cables.
    Does the gel have a shelf life?
    No, the gel has no expiry date and is non-toxic.

    Gel T-branch joint | 1 × 95–240 mm² | branch 1 × 50–120 mm² | without connectors | 0.6/1 kV | 250 × 143 × 46 mm | IP68 | SHARK 435/S | SH1435

    Gel T-branch joint | 1 × 95–240 mm² | branch 1 × 50–120 mm² | without connectors | 0.6/1 kV | 250 × 143 × 46 mm | IP68 | SHARK 435/S | SH1435 – a sealed, quick-to-install solution for electrical connections outdoors, underground and in damp locations. Available at elsprendimai.eu – ELSprendimai has checked the technical data and will help you choose the right size.

    Published: 2026-11-18 · Data checked against manufacturer and supplier data: 2026-11-18

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Terminal block | electrical wire connector | spring-loaded | lever-operated | 5x0.08-2.5mm² | max. 4mm² | WAGO | 222-415 | 4044918464956
    Code: 4044918464956

    Installation spring terminal connector with foldable levers, designed for fast, reliable and tidy electrical wire connection without screws or additional tools. This terminal block is especially useful when performing electrical installation, lighting, junction box, automation or renovation work, where wires need to be quickly connected, disconnected or inspected. 

    Price 0.52 € VAT incl.
    ( 0.43 € VAT excl. )
    CYKY-L 5G10 | 5×10 mm² | Copper power cable | 450/750 V | black | 1 m | Lietkabelis
    Code: 91951013

    CYKY-L 5G10 (5×10 mm²) – 450/750 V copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. AB Lietkabelis, price per 1 m.

    Price 8.67 € VAT incl.
    ( 7.17 € VAT excl. )
    Modular three-phase smart energy meter with relay | 60 A | 3×230/400 V | Wi-Fi Tuya | remote control | U/I protection | RS485 | DIN | Tomzn TO-DTS238
    Code: TO-DTS238

    Three-phase DIN meter with a built-in relay for 3×230/400 V networks up to 60 A. Via Wi-Fi and the Tuya app it shows U, I, P, PF, frequency and imported / exported energy separately, and lets you switch the supply on / off remotely, set a timer and configure voltage / overload protection. It also has RS485 Modbus RTU; intended for non-billing (internal) metering.

    Price 145.20 € VAT incl.
    ( 120.00 € VAT excl. )
    Single-cable membrane entry flange | for Ø86 mm hole | cable Ø55–70 mm | flange Ø123.1 mm | grey | IP67 | HT Hi Tech Polymers | HTX-1
    Code: Sandariklis HTX-1

    HTX-1 is a membrane entry flange for one thick power cable Ø55–70 mm. It fits a round Ø86 mm hole in the enclosure wall, flange diameter Ø123.1 mm. Sealing rating is IP67 according to the latest manufacturer's sheet.

    Price 21.78 € VAT incl.
    ( 18.00 € VAT excl. )
    Cable gland with locknut and gasket | PG7 | for cable Ø3–6.5 mm | grey | IP68 | 4772124000810
    Code: 00810

    Plastic PG7 cable gland with locknut and gasket for routing Ø3–6.5 mm round cables into distribution boards and junction boxes. Provides IP68 sealing when correctly installed.

    Price 0.20 € VAT incl.
    ( 0.17 € VAT excl. )
    Flexible copper cable H03VV-F | 3G0.75 mm² | 300/300 V | round | black | 1 m | Lietkabelis
    Code: 91530702

    H03VV-F 3G0.75 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a black PVC sheath, 300/300 V. Sold by the metre.

    Cores: L, N, PE. Indicative current ≈ 6 A – for light appliances indoors.

    Price 0.54 € VAT incl.
    ( 0.44 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information