    Code: A9K02102

    Schneider Electric Acti9 K60N is a high-quality miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. This 1-pole (1P), 2A rated current circuit breaker with a C-trip characteristic ensures reliable protection in residential, commercial, and industrial electrical distribution boards.

    The Acti9 series is one of Schneider Electric's most popular protection equipment lines, valued for its durability, reliability, and compliance with strict European standards. The K60N model is designed to protect cables, control circuits, automation systems, signalling lines, and other low-power electrical loads. 

  • Technical Specifications
    Manufacturer: Schneider Electric
    Series: Acti9
    Model: K60N
    Product type: Miniature Circuit Breaker (MCB)
    Poles: 1P
    Number of protected poles: 1
    Rated current (In): 2A
    Tripping characteristic: C
    Network type: AC
    Rated operational voltage (Ue): 230V AC
    Network frequency: 50/60 Hz
    Short-circuit breaking capacity (Icn): 6000A (6kA)
    Service short-circuit breaking capacity (Ics): 6000A
    Magnetic tripping threshold: 5–10 × In
    Protection technology: Thermal-magnetic
    Insulation voltage (Ui): 440V AC
    Impulse withstand voltage (Uimp): 4kV
    Energy limitation class: 3
    Mounting: DIN rail
    Number of modules: 1 module (18 mm)
    Width: 18 mm
    Height: 81 mm
    Depth: 70 mm
    Colour: White (RAL9003)
    Mechanical endurance: 20,000 cycles
    Electrical endurance: 20,000 cycles
    Protection rating: IP20
    Protection rating inside enclosure: IP40
    Operating temperature: -25°C to +70°C
    Storage temperature: -40°C to +70°C
    Certifications: VDE, OVE
    Standard: EN/IEC 60898-1
    Functions
    Overload protection: Thermal tripping mechanism protects cables and equipment against prolonged overcurrent.
    Short-circuit protection: Magnetic mechanism quickly disconnects the circuit in case of a short circuit.
    Manual operation: Allows safe switching on, switching off, or isolating the electrical circuit during maintenance work.
    Fast switching: Contact closing is independent of handle operation speed, ensuring reliable performance.
    Comb busbar compatibility: Suitable for Schneider Electric Biconnect distribution systems.
    DIN rail mounting: Quick and convenient installation in standard electrical distribution boards.
    Applications

    For household users: Suitable for protecting low-power electrical circuits such as alarm systems, intercoms, control transformers, automation circuits, low-power lighting systems, and gate automation. The 2A rating is generally used for dedicated protection or control circuits rather than general household wiring.

    For electricians: Reliable choice for distribution board assembly, automation circuit protection, control cabinets, signalling and auxiliary circuits, and low-power electrical loads. The compact 18 mm width allows easy integration into new or existing panels.

    For engineers and designers: Suitable for industrial automation systems, control cabinets, PLC control circuits, process protection circuits, and machine electrical schematics. The 6kA breaking capacity allows use in many standard distribution systems.

    Advantages
    Schneider Electric Acti9 professional series
    Reliable overload and short-circuit protection
    6kA short-circuit breaking capacity
    C characteristic suitable for most control and automation circuits
    Long service life – 20,000 mechanical and electrical cycles
    Easy DIN rail installation
    Compatible with Biconnect comb busbars
    Certified according to EN/IEC 60898-1
    Compact 18 mm width
    Disadvantages
    2A rated current is not suitable for higher-power electrical loads
    No contact position indicator
    No integrated residual current protection (RCD function)
    IP20 protection requires installation inside an enclosed distribution board
    Frequently Asked Questions (FAQ)

    1. What does the C characteristic mean?

    C-curve circuit breakers trip at 5–10 times the rated current. They are suitable for circuits where temporary inrush currents may occur, such as automation and control equipment.

    2. Is this breaker suitable for a household lighting circuit?

    Usually not. A 2A rating is relatively low and is typically used for control, signalling, or specialised low-power circuits rather than general lighting.

    3. Does this circuit breaker protect against electrical leakage?

    No. This is an MCB circuit breaker that only protects against overloads and short circuits. Residual current protection requires an RCD or RCBO device.

    4. Can it be installed in a standard DIN rail enclosure?

    Yes. The breaker is designed for installation on a standard 35 mm DIN rail and occupies one 18 mm module space. 