  • Ring cable lug | 120mm² | M16 | crimp | TCD-120/16 | DIN 46235 | 005730

    Code: 005730
  • Ring cable lug | 120mm² | M16 | crimp | TCD-120/16 | DIN 46235 | 005730

    TCD-120/16 – crimp ring cable lug 120 mm² for a copper conductor with a stud hole for an M16 bolt. Made to DIN 46235 – a standardised type of compression lug for copper conductors. Used to terminate a cable or wire end and connect it reliably to a terminal, busbar or device bolt.

    Key idea:
    The lug is selected by two values: conductor cross-section (120 mm²) and the size of the bolt it is connected to (M16). Large cross-section lugs are used for power cables at transformers, switch-disconnectors, busbars and incoming devices. A correctly crimped lug forms a mechanically strong, low-resistance connection.
    Conductor cross-section
    120 mm²
    Stud hole
    M16
    Connection
    crimp
    Series / marking
    TCD-120/16 (DIN 46235)

    Operating principle

    Insulation is stripped from the conductor to the depth of the lug barrel and the strands are pushed fully into the barrel.

    The barrel is crimped with a crimping tool using a die for 120 mm² (hexagonal dies are used for DIN 46235 lugs). During crimping the barrel deforms together with the conductor – a solid joint is formed without a screw contact on the strands.

    The ring part with the M16 hole is bolted to the terminal or busbar, and the crimp area is insulated with heat-shrink tubing.

    Why choose TCD-120/16?
    An exact cross-section and bolt combination (120 mm² / M16) – no need to enlarge the hole or crimp a wrong-size lug, so the joint stays reliable throughout its service life.

    Technical specifications

    Product typeCrimp ring cable lug
    Marking / codeTCD-120/16 / 005730
    SeriesTCD
    Conductor cross-section120 mm²
    Stud hole (bolt)M16
    Conductorcopper
    Connection methodcrimping
    StandardDIN 46235

    Main functions

    • Conductor termination – the 120 mm² conductor is secured and does not splay under the bolt.
    • Crimped joint – strong mechanical and electrical connection without an extra screw on the strands.
    • M16 stud hole – fits an M16 bolt or stud directly.
    • DIN 46235 – standardised dimensions make it easy to choose the crimping die.
    • Easy identification – cross-section and bolt size are given in the marking TCD-120/16.

    Where is it used?

    • Transformer substations and switchgear
    • Switch-disconnectors and power switches
    • Busbar systems
    • High-power incomers
    • Generator and power factor correction connections
    • Industrial power circuits

    Use by need

    For the installing electrician.
    One clear 120 mm² / M16 combination – fewer errors when building a panel.
    For the equipment repair technician.
    A damaged or overheated lug is replaced with a product of the same size.
    For the designer and buyer.
    The DIN 46235 marking makes it easy to specify the lug precisely.

    Practical application

    If a 120 mm² copper cable has to be connected in a panel to a busbar or device with an M16 bolt, use TCD-120/16: strip the insulation, push the conductor into the barrel, crimp with a 120 mm² die and insulate the joint with heat-shrink tubing.

    Advantages

    • Exact cross-section and bolt combination
    • Reliable crimped joint
    • Suitable for copper conductors
    • Standardised to DIN 46235
    • Compact ring part

    Disadvantages / limitations

    • Uninsulated – the crimp area must be insulated with heat-shrink tubing
    • Requires a crimping tool and the correct die
    • Not suitable for aluminium conductors – use bimetallic lugs
    • A lug of the wrong cross-section will not form a reliable joint

    Safety and installation notes

    • Install only with the voltage disconnected and its absence verified
    • Use a die intended for 120 mm²
    • Push the conductor to the end of the barrel, leave no protruding strands
    • Do not crimp several conductors in one lug unless intended
    • Tighten the bolt to the torque specified by the equipment manufacturer
    • After installation, check that the joint does not heat up under load

    Quick selection guide

    120 mm²
    M16
    crimp
    TCD DIN 46235
    for copper
    Suitable when you need:
    • to terminate a 120 mm² copper conductor
    • to connect to an M16 bolt or stud
    • a durable crimped joint in a panel or device
    Check before use:
    • whether the conductor cross-section is exactly 120 mm²
    • whether the terminal bolt is M16
    • whether you have the right crimping tool and die
    • whether the conductor is copper (bimetallic lugs for aluminium)
    Important reminder: A lug does not replace insulation of the joint – cover the crimp area with heat-shrink tubing.

    FAQ

    How do I choose a ring lug?
    By the conductor cross-section (120 mm²) and the bolt size (M16) – both must match.
    Is it suitable for aluminium cable?
    No – bimetallic (Al/Cu) lugs are used for aluminium conductors.
    Which tool is used for crimping?
    Crimping pliers or a hydraulic press with a 120 mm² die.
    Can it be fitted to a larger bolt?
    No – the M16 hole is only for an M16 bolt; choose another lug for a different bolt.
    Does it need insulating?
    Yes – the lug is uninsulated; cover the crimp area with heat-shrink tubing.
    What is DIN 46235?
    It is a standard for compression lugs for copper conductors with defined dimensions.

    Ring cable lug | 120mm² | M16 | crimp | TCD-120/16 | DIN 46235 | 005730

    TCD-120/16 – crimp ring cable lug 120 mm² M16 to DIN 46235 for terminating copper conductors and connecting them to panels, busbars and equipment terminals.

    Published: 2026-11-12 · Parameters according to the supplier's specification: 2026-11-12

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Electrical distribution enclosure | surface-mounted | plastic | 700x500x245 mm | IP65 | IK08 | with mounting plate | FAMATEL MAGNA 39157
    Code: 39157

    FAMATEL MAGNA 39157 is a sealed, surface-mounted plastic enclosure measuring 700x500x245 mm for mounting distribution and automation equipment outdoors or in damp rooms. The ABS housing has double insulation, a white door with a lock, and a height-adjustable metal mounting plate – equipment is installed on the plate, while the housing protects it from dust, water jets and impacts.

    Price 153.48 € VAT incl.
    ( 126.84 € VAT excl. )
    Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1m | Black
    Code: AXMK 4x120

    AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C. 

    Price 15.13 € VAT incl.
    ( 12.50 € VAT excl. )
    Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1000m | Black
    Code: SKU#165996553256573221

    AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C.  

    Sold by the drum, i.e. the minimum order quantity is 1000 metres.

    Delivery time: up to 6 weeks. 

    Price 11.04 € VAT incl.
    ( 9.12 € VAT excl. )
  • privacy policy

    Information