Ring cable lug | 1.5mm² | M6 | crimp | T-1,5/6 | 010120
Code: 010120Price 0.13 € VAT incl.( 0.11 € VAT excl. )-
Ring cable lug | 1.5mm² | M6 | crimp | T-1,5/6 | 010120
T-1,5/6 – crimp ring cable lug 1.5 mm² for a copper conductor with a stud hole for an M6 bolt. Used to terminate a cable or wire end and connect it reliably to a terminal, busbar or device bolt.
Key idea:
The lug is selected by two values: conductor cross-section (1.5 mm²) and the size of the bolt it is connected to (M6). Small cross-section lugs are used in control circuits, panels and equipment connections. A correctly crimped lug forms a mechanically strong, low-resistance connection.Conductor cross-section
1.5 mm²Stud hole
M6Connection
crimpSeries / marking
T-1,5/6Operating principle
Insulation is stripped from the conductor to the depth of the lug barrel and the strands are pushed fully into the barrel.
The barrel is crimped with a crimping tool using a die for 1.5 mm². During crimping the barrel deforms together with the conductor – a solid joint is formed without a screw contact on the strands.
The ring part with the M6 hole is bolted to the terminal or busbar, and the crimp area is insulated with heat-shrink tubing.
Why choose T-1,5/6?
An exact cross-section and bolt combination (1.5 mm² / M6) – no need to enlarge the hole or crimp a wrong-size lug, so the joint stays reliable throughout its service life.Technical specifications
Product type Crimp ring cable lug Marking / code T-1,5/6 / 010120 Series T Conductor cross-section 1.5 mm² Stud hole (bolt) M6 Conductor copper Connection method crimping Main functions
- Conductor termination – the 1.5 mm² conductor is secured and does not splay under the bolt.
- Crimped joint – strong mechanical and electrical connection without an extra screw on the strands.
- M6 stud hole – fits an M6 bolt or stud directly.
- T series – lugs of one type across the whole range of cross-sections and bolt sizes.
- Easy identification – cross-section and bolt size are given in the marking T-1,5/6.
Where is it used?
- Control and automation panels
- Earthing and equipotential bonding conductors
- Motor and pump terminals
- Heating and ventilation equipment connections
- Auxiliary circuits of solar plants and inverters
- Production equipment repair
Use by need
For the installing electrician.
One clear 1.5 mm² / M6 combination – fewer errors when building a panel.For the equipment repair technician.
A damaged or overheated lug is replaced with a product of the same size.For the designer and buyer.
The complete T series – from small to large cross-sections.Practical application
If a 1.5 mm² copper cable has to be connected in a panel to a busbar or device with an M6 bolt, use T-1,5/6: strip the insulation, push the conductor into the barrel, crimp with a 1.5 mm² die and insulate the joint with heat-shrink tubing.Advantages
- Exact cross-section and bolt combination
- Reliable crimped joint
- Suitable for copper conductors
- Consistent series system
- Compact ring part
Disadvantages / limitations
- Uninsulated – the crimp area must be insulated with heat-shrink tubing
- Requires a crimping tool and the correct die
- Not suitable for aluminium conductors – use bimetallic lugs
- A lug of the wrong cross-section will not form a reliable joint
Safety and installation notes
- Install only with the voltage disconnected and its absence verified
- Use a die intended for 1.5 mm²
- Push the conductor to the end of the barrel, leave no protruding strands
- Do not crimp several conductors in one lug unless intended
- Tighten the bolt to the torque specified by the equipment manufacturer
- After installation, check that the joint does not heat up under load
Quick selection guide
1.5 mm²M6crimpTfor copperSuitable when you need:- to terminate a 1.5 mm² copper conductor
- to connect to an M6 bolt or stud
- a durable crimped joint in a panel or device
Check before use:- whether the conductor cross-section is exactly 1.5 mm²
- whether the terminal bolt is M6
- whether you have the right crimping tool and die
- whether the conductor is copper (bimetallic lugs for aluminium)
Important reminder: A lug does not replace insulation of the joint – cover the crimp area with heat-shrink tubing.FAQ
How do I choose a ring lug?
By the conductor cross-section (1.5 mm²) and the bolt size (M6) – both must match.Is it suitable for aluminium cable?
No – bimetallic (Al/Cu) lugs are used for aluminium conductors.Which tool is used for crimping?
Crimping pliers or a hydraulic press with a 1.5 mm² die.Can it be fitted to a larger bolt?
No – the M6 hole is only for an M6 bolt; choose another lug for a different bolt.Does it need insulating?
Yes – the lug is uninsulated; cover the crimp area with heat-shrink tubing.What is the difference between the T and TCD series?
The TCD series is made to DIN 46235; T is another series in this group. Both are crimp lugs for copper conductors.Ring cable lug | 1.5mm² | M6 | crimp | T-1,5/6 | 010120
T-1,5/6 – crimp ring cable lug 1.5 mm² M6 for terminating copper conductors and connecting them to panels, busbars and equipment terminals.
Published: 2026-11-12 · Parameters according to the supplier's specification: 2026-11-12
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1m | BlackCode: AXMK 4x120AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C.
Price 15.13 € VAT incl.( 12.50 € VAT excl. )Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1000m | BlackCode: SKU#165996553256573221AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C.
Sold by the drum, i.e. the minimum order quantity is 1000 metres.
Delivery time: up to 6 weeks.
Price 11.04 € VAT incl.( 9.12 € VAT excl. )Electrical distribution enclosure | surface-mounted | plastic | 700x500x245 mm | IP65 | IK08 | with mounting plate | FAMATEL MAGNA 39157Code: 39157FAMATEL MAGNA 39157 is a sealed, surface-mounted plastic enclosure measuring 700x500x245 mm for mounting distribution and automation equipment outdoors or in damp rooms. The ABS housing has double insulation, a white door with a lock, and a height-adjustable metal mounting plate – equipment is installed on the plate, while the housing protects it from dust, water jets and impacts.
Price 153.48 € VAT incl.( 126.84 € VAT excl. )