  • Ring cable lug | 16mm² | M5 | crimp | T-16/5 | 010310

    Code: 010310
  • Ring cable lug | 16mm² | M5 | crimp | T-16/5 | 010310

    T-16/5 – crimp ring cable lug 16 mm² for a copper conductor with a stud hole for an M5 bolt. Used to terminate a cable or wire end and connect it reliably to a terminal, busbar or device bolt.

    Key idea:
    The lug is selected by two values: conductor cross-section (16 mm²) and the size of the bolt it is connected to (M5). Lugs of this cross-section are typically used in distribution boards, incomers, inverters and battery circuits. A correctly crimped lug forms a mechanically strong, low-resistance connection.
    Conductor cross-section
    16 mm²
    Stud hole
    M5
    Connection
    crimp
    Series / marking
    T-16/5

    Operating principle

    Insulation is stripped from the conductor to the depth of the lug barrel and the strands are pushed fully into the barrel.

    The barrel is crimped with a crimping tool using a die for 16 mm². During crimping the barrel deforms together with the conductor – a solid joint is formed without a screw contact on the strands.

    The ring part with the M5 hole is bolted to the terminal or busbar, and the crimp area is insulated with heat-shrink tubing.

    Why choose T-16/5?
    An exact cross-section and bolt combination (16 mm² / M5) – no need to enlarge the hole or crimp a wrong-size lug, so the joint stays reliable throughout its service life.

    Technical specifications

    Product typeCrimp ring cable lug
    Marking / codeT-16/5 / 010310
    SeriesT
    Conductor cross-section16 mm²
    Stud hole (bolt)M5
    Conductorcopper
    Connection methodcrimping

    Main functions

    • Conductor termination – the 16 mm² conductor is secured and does not splay under the bolt.
    • Crimped joint – strong mechanical and electrical connection without an extra screw on the strands.
    • M5 stud hole – fits an M5 bolt or stud directly.
    • T series – lugs of one type across the whole range of cross-sections and bolt sizes.
    • Easy identification – cross-section and bolt size are given in the marking T-16/5.

    Where is it used?

    • Distribution and incoming panels
    • Earthing busbars
    • Inverters and solar plants
    • Battery and UPS circuits
    • Motor and compressor supply
    • Generator connection

    Use by need

    For the installing electrician.
    One clear 16 mm² / M5 combination – fewer errors when building a panel.
    For the equipment repair technician.
    A damaged or overheated lug is replaced with a product of the same size.
    For the designer and buyer.
    The complete T series – from small to large cross-sections.

    Practical application

    If a 16 mm² copper cable has to be connected in a panel to a busbar or device with an M5 bolt, use T-16/5: strip the insulation, push the conductor into the barrel, crimp with a 16 mm² die and insulate the joint with heat-shrink tubing.

    Advantages

    • Exact cross-section and bolt combination
    • Reliable crimped joint
    • Suitable for copper conductors
    • Consistent series system
    • Compact ring part

    Disadvantages / limitations

    • Uninsulated – the crimp area must be insulated with heat-shrink tubing
    • Requires a crimping tool and the correct die
    • Not suitable for aluminium conductors – use bimetallic lugs
    • A lug of the wrong cross-section will not form a reliable joint

    Safety and installation notes

    • Install only with the voltage disconnected and its absence verified
    • Use a die intended for 16 mm²
    • Push the conductor to the end of the barrel, leave no protruding strands
    • Do not crimp several conductors in one lug unless intended
    • Tighten the bolt to the torque specified by the equipment manufacturer
    • After installation, check that the joint does not heat up under load

    Quick selection guide

    16 mm²
    M5
    crimp
    T
    for copper
    Suitable when you need:
    • to terminate a 16 mm² copper conductor
    • to connect to an M5 bolt or stud
    • a durable crimped joint in a panel or device
    Check before use:
    • whether the conductor cross-section is exactly 16 mm²
    • whether the terminal bolt is M5
    • whether you have the right crimping tool and die
    • whether the conductor is copper (bimetallic lugs for aluminium)
    Important reminder: A lug does not replace insulation of the joint – cover the crimp area with heat-shrink tubing.

    FAQ

    How do I choose a ring lug?
    By the conductor cross-section (16 mm²) and the bolt size (M5) – both must match.
    Is it suitable for aluminium cable?
    No – bimetallic (Al/Cu) lugs are used for aluminium conductors.
    Which tool is used for crimping?
    Crimping pliers or a hydraulic press with a 16 mm² die.
    Can it be fitted to a larger bolt?
    No – the M5 hole is only for an M5 bolt; choose another lug for a different bolt.
    Does it need insulating?
    Yes – the lug is uninsulated; cover the crimp area with heat-shrink tubing.
    What is the difference between the T and TCD series?
    The TCD series is made to DIN 46235; T is another series in this group. Both are crimp lugs for copper conductors.

    Ring cable lug | 16mm² | M5 | crimp | T-16/5 | 010310

    T-16/5 – crimp ring cable lug 16 mm² M5 for terminating copper conductors and connecting them to panels, busbars and equipment terminals.

    Published: 2026-11-12 · Parameters according to the supplier's specification: 2026-11-12

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Electrical distribution enclosure | surface-mounted | plastic | 700x500x245 mm | IP65 | IK08 | with mounting plate | FAMATEL MAGNA 39157
    Code: 39157

    FAMATEL MAGNA 39157 is a sealed, surface-mounted plastic enclosure measuring 700x500x245 mm for mounting distribution and automation equipment outdoors or in damp rooms. The ABS housing has double insulation, a white door with a lock, and a height-adjustable metal mounting plate – equipment is installed on the plate, while the housing protects it from dust, water jets and impacts.

    Price 153.48 € VAT incl.
    ( 126.84 € VAT excl. )
    Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1m | Black
    Code: AXMK 4x120

    AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C. 

    Price 15.13 € VAT incl.
    ( 12.50 € VAT excl. )
    Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1000m | Black
    Code: SKU#165996553256573221

    AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C.  

    Sold by the drum, i.e. the minimum order quantity is 1000 metres.

    Delivery time: up to 6 weeks. 

    Price 11.04 € VAT incl.
    ( 9.12 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information