Products catalog

  • Ring cable lug | 50mm² | M8 | crimp | T-50/8 | 010510

    Code: 010510

    Ring cable lug designed for reliable and safe connection of copper conductors to electrical equipment, distribution cabinets, grounding systems, contactors, circuit breakers, and other electrical installation components. The lug is manufactured from high-quality electrolytic copper and coated with a tin layer, which ensures better electrical contact, protection against corrosion, and long service life even under demanding operating conditions.  

  • Ring cable lug | 50mm² | M8 | crimp | T-50/8 | 010510

    T-50/8 – crimp ring cable lug 50 mm² for a copper conductor with a stud hole for an M8 bolt. Used to terminate a cable or wire end and connect it reliably to a terminal, busbar or device bolt.

    Key idea:
    The lug is selected by two values: conductor cross-section (50 mm²) and the size of the bolt it is connected to (M8). Lugs of this cross-section are typically used in distribution boards, incomers, inverters and battery circuits. A correctly crimped lug forms a mechanically strong, low-resistance connection.
    Conductor cross-section
    50 mm²
    Stud hole
    M8
    Connection
    crimp
    Series / marking
    T-50/8

    Operating principle

    Insulation is stripped from the conductor to the depth of the lug barrel and the strands are pushed fully into the barrel.

    The barrel is crimped with a crimping tool using a die for 50 mm². During crimping the barrel deforms together with the conductor – a solid joint is formed without a screw contact on the strands.

    The ring part with the M8 hole is bolted to the terminal or busbar, and the crimp area is insulated with heat-shrink tubing.

    Why choose T-50/8?
    An exact cross-section and bolt combination (50 mm² / M8) – no need to enlarge the hole or crimp a wrong-size lug, so the joint stays reliable throughout its service life.

    Technical specifications

    Product typeCrimp ring cable lug
    Marking / codeT-50/8 / 010510
    SeriesT
    Conductor cross-section50 mm²
    Stud hole (bolt)M8
    Conductorcopper
    Connection methodcrimping

    Main functions

    • Conductor termination – the 50 mm² conductor is secured and does not splay under the bolt.
    • Crimped joint – strong mechanical and electrical connection without an extra screw on the strands.
    • M8 stud hole – fits an M8 bolt or stud directly.
    • T series – lugs of one type across the whole range of cross-sections and bolt sizes.
    • Easy identification – cross-section and bolt size are given in the marking T-50/8.

    Where is it used?

    • Distribution and incoming panels
    • Earthing busbars
    • Inverters and solar plants
    • Battery and UPS circuits
    • Motor and compressor supply
    • Generator connection

    Use by need

    For the installing electrician.
    One clear 50 mm² / M8 combination – fewer errors when building a panel.
    For the equipment repair technician.
    A damaged or overheated lug is replaced with a product of the same size.
    For the designer and buyer.
    The complete T series – from small to large cross-sections.

    Practical application

    If a 50 mm² copper cable has to be connected in a panel to a busbar or device with an M8 bolt, use T-50/8: strip the insulation, push the conductor into the barrel, crimp with a 50 mm² die and insulate the joint with heat-shrink tubing.

    Advantages

    • Exact cross-section and bolt combination
    • Reliable crimped joint
    • Suitable for copper conductors
    • Consistent series system
    • Compact ring part

    Disadvantages / limitations

    • Uninsulated – the crimp area must be insulated with heat-shrink tubing
    • Requires a crimping tool and the correct die
    • Not suitable for aluminium conductors – use bimetallic lugs
    • A lug of the wrong cross-section will not form a reliable joint

    Safety and installation notes

    • Install only with the voltage disconnected and its absence verified
    • Use a die intended for 50 mm²
    • Push the conductor to the end of the barrel, leave no protruding strands
    • Do not crimp several conductors in one lug unless intended
    • Tighten the bolt to the torque specified by the equipment manufacturer
    • After installation, check that the joint does not heat up under load

    Quick selection guide

    50 mm²
    M8
    crimp
    T
    for copper
    Suitable when you need:
    • to terminate a 50 mm² copper conductor
    • to connect to an M8 bolt or stud
    • a durable crimped joint in a panel or device
    Check before use:
    • whether the conductor cross-section is exactly 50 mm²
    • whether the terminal bolt is M8
    • whether you have the right crimping tool and die
    • whether the conductor is copper (bimetallic lugs for aluminium)
    Important reminder: A lug does not replace insulation of the joint – cover the crimp area with heat-shrink tubing.

    FAQ

    How do I choose a ring lug?
    By the conductor cross-section (50 mm²) and the bolt size (M8) – both must match.
    Is it suitable for aluminium cable?
    No – bimetallic (Al/Cu) lugs are used for aluminium conductors.
    Which tool is used for crimping?
    Crimping pliers or a hydraulic press with a 50 mm² die.
    Can it be fitted to a larger bolt?
    No – the M8 hole is only for an M8 bolt; choose another lug for a different bolt.
    Does it need insulating?
    Yes – the lug is uninsulated; cover the crimp area with heat-shrink tubing.
    What is the difference between the T and TCD series?
    The TCD series is made to DIN 46235; T is another series in this group. Both are crimp lugs for copper conductors.

    Ring cable lug | 50mm² | M8 | crimp | T-50/8 | 010510

    T-50/8 – crimp ring cable lug 50 mm² M8 for terminating copper conductors and connecting them to panels, busbars and equipment terminals.

    Published: 2026-11-12 · Parameters according to the supplier's specification: 2026-11-12

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    CYKY-J 5G16 | 5×16 mm² | Copper power cable | 0.6/1 kV | black | 1 m | NKT
    Code: C520218

    CYKY-J 5G16 (5×16 mm²) – 0.6/1 kV copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. NKT, price per 1 m.

    Price 15.00 € VAT incl.
    ( 12.40 € VAT excl. )
    Copper installation cable NYM-J | 5×2.5 mm² | 300/500 V | white | 1 m | Lietkabelis KH05VV-U 5G2.5
    Code: 92052501

    NYM-J 5×2.5 mm² (KH05VV-U 5G2.5) – AB Lietkabelis copper installation cable with solid class 1 conductors, PVC insulation and a white PVC sheath, 300/500 V. For fixed installation inside buildings: in walls, under plaster, in conduits and trunking. Sold by the metre.

    5 cores (L1, L2, L3, N, PE) for three-phase 400 V installation with neutral: three-phase sockets, cookers, sub-boards and mixed loads.

    Price 2.38 € VAT incl.
    ( 1.97 € VAT excl. )
    CYKY-L 5G10 | 5×10 mm² | Copper power cable | 450/750 V | black | 1 m | Lietkabelis
    Code: 91951013

    CYKY-L 5G10 (5×10 mm²) – 450/750 V copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. AB Lietkabelis, price per 1 m.

    Price 8.67 € VAT incl.
    ( 7.17 € VAT excl. )
    Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1m | Black
    Code: AXMK 4x120

    AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C. 

    Price 15.13 € VAT incl.
    ( 12.50 € VAT excl. )
    Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1000m | Black
    Code: SKU#165996553256573221

    AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C.  

    Sold by the drum, i.e. the minimum order quantity is 1000 metres.

    Delivery time: up to 6 weeks. 

    Price 11.04 € VAT incl.
    ( 9.12 € VAT excl. )
    Aluminium power cable | 4x150mm² | AXMK | Class 2 | 500m | black
    Code: SKU#165996595240116261

    Aluminium power cable AXMK 4×150 mm², designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black PVC outer sheath resistant to UV radiation. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, pipes, and concrete. Maximum operating temperature – 90 °C.  

    Sold by the drum, i.e. the minimum order quantity is 500 metres.

    Delivery time: up to 6 weeks. 

    Price 14.52 € VAT incl.
    ( 12.00 € VAT excl. )
  • Subscribtion to new arrivals