Panel-mounted | smart | digital power factor controller | 6 steps | 110-480VAC | IP30/51 | Lifasa | MASTER06
Code: MASTER06Price 253.25 € VAT incl.( 209.30 € VAT excl. )Lifasa MASTER06 – 6-step automatic power factor (cos φ) controller with network analyser functions. Supply 110–480 V AC, measurement via 1 or 3 CTs (/5 A or /1 A), 17 configurable alarms, temperature and leakage monitoring, RS-485 Modbus RTU. Front 144 × 144 mm.
-
Panel-mounted | smart | digital power factor controller | 6 steps | 110-480VAC | IP30/51 | Lifasa | MASTER06
Lifasa MASTER Control Var 06 is a 6-step automatic power factor (cos φ) controller for capacitor banks. It measures network parameters, switches capacitor steps automatically via contactors and features built-in network analyser functions.
Key idea:
MASTER06 is the right choice when maintaining cos φ alone is not enough: you need to see harmonics, capacitor condition and cabinet temperature, and transfer data to SCADA via Modbus. It is an advanced-class controller for medium-sized capacitor banks.Steps
6 relay outputsPower supply
110–480 V AC ±10 %Current measurement
1 or 3 CTs, /5 A or /1 ACommunication
RS-485, Modbus RTUOperating principle
The controller is mounted in the cabinet door (panel mounting). Voltage is connected to the phases, and current is measured via one or three current transformers (CTs) installed at the incoming supply so that they measure the entire site load, including the capacitors.
Based on the measured reactive power, the controller switches steps on and off via capacitor contactors using its 6 relay outputs. The FCP algorithm selects the step combination that minimises the number of switching operations, extending the service life of contactors and capacitors.
The result: cos φ is kept within the set limits, while network parameters, harmonics, alarms and the switching count of each step are visible on the display and via Modbus.
Why choose MASTER06?
A single device does the job of both a controller and a network analyser: you see not only cos φ but also the reasons why compensation is not working (harmonics, overheating, a failed step). This shortens troubleshooting and helps protect the capacitors.Technical specifications
Product type Automatic power factor (cos φ) controller Manufacturer / model Lifasa / MASTER Control Var, MASTER06 Number of steps (relays) 6 Supply voltage 110–480 V AC ±10 %, 45–65 Hz Voltage measurement up to 525 V AC (phase–phase), up to 300 V AC (phase–N) Current measurement 1 or 3 current transformers, secondary /5 A or /1 A (CTs not included) Measurement accuracy voltage and current ±1 %; cos φ ±2 % ±1 digit Temperature measurement 0–80 °C, ±3 °C Leakage current monitoring 10 mA – 1 A (primary), with a WGC series transformer Outputs relay outputs for steps, alarm relay (changeover contact), fan relay, 2 NPN digital outputs 24 V DC / 50 mA Inputs 2 digital Alarms 17 fully configurable cos φ targets up to 4 different values for different time periods Communication RS-485, Modbus RTU Degree of protection (EN 60529) IP51 when mounted, IP30 when not mounted (according to the latest manufacturer data) Front dimensions 144 × 144 mm Mounting panel (cabinet door) Operating temperature −20 … +60 °C, relative humidity up to 95 % non-condensing Electrical safety installation category III, class II (EN 61010-1) Standards IEC 62053-23, IEC 61326-1, EN 61010-1, UL 508 Key functions
- Automatic cos φ control – steps are switched according to the actual reactive power, without operator intervention
- FCP algorithm – minimum number of switching operations – longer service life of contactors and capacitors
- 1 or 3 CTs – with three CTs it also measures unbalanced loads correctly
- Network analyser functions – voltage, current, harmonics, active, reactive and apparent power on one display
- Temperature and leakage monitoring – gives early warning of an overheated cabinet or a failing step
- Up to 4 cos φ targets – different targets for daytime, night-time or weekends
- Modbus RTU – data and alarms are transferred to SCADA or a building management system
Where is it used?
- Automatic capacitor banks in factories and production halls
- Substations and distribution boards with several transformers
- Sites with unbalanced loads (many single-phase consumers)
- Retrofitting old capacitor banks by replacing an outdated controller
- Medium-voltage compensation equipment (as specified by the manufacturer)
- Sites where compensation needs to be monitored remotely
Use by need
For capacitor bank builders.
One model suits a wide range of cabinets – the CT ratio, phases and steps are set in the menu, with no rewiring needed.For the site energy manager.
It measures not only cos φ but also harmonics and temperature, so a fault can be spotted before a capacitor burns out.For automation / SCADA integrators.
Modbus RTU over RS-485 allows the compensation status and alarms to be displayed in a common control system.Practical application
If an old controller at a factory keeps "hunting" between steps and the capacitors run hot, MASTER06 with three CTs will show whether the load is unbalanced and what the current harmonics are. Then, instead of blindly replacing capacitors, you can decide whether correctly configuring the steps is enough or whether the cabinet needs detuning reactors.Pros
- Built-in network analyser functions
- 1 or 3 CTs, /5 A or /1 A
- 17 configurable alarms and a dedicated alarm relay
- Temperature and leakage current monitoring
- Up to 4 cos φ targets for different time periods
- RS-485 Modbus RTU
- Wide supply range 110–480 V AC
Cons / limitations
- More expensive than basic controllers – for a small cabinet with no monitoring needs a simpler model (e.g. MCE ADV) is sufficient
- CTs and WGC transformers must be purchased separately
- Dust and moisture protection only from the front, when mounted
- Full functionality requires configuration know-how
Safety and installation notes
- Before any work, disconnect the power supply and make sure the capacitors are discharged
- The CT secondary circuit must never be left open – short-circuit the CT terminals before disconnecting the controller
- Install the CTs at the incoming supply so that they measure the entire load, including the capacitors
- Protect the power supply and relay circuits with the fuses specified by the manufacturer
- Use the relay outputs to switch contactor coils only, never capacitors directly
Quick selection guide
6 steps110–480 V ACCT /5 A or /1 ARS-485 Modbus144 × 144 mmSuitable when you need:- automatic cos φ control in a medium or large cabinet
- monitoring of harmonics, temperature and step condition
- transfer of compensation data to SCADA
Check before use:- whether 6 steps are enough (for a larger cabinet – MASTER12)
- the CT ratio and quantity (1 or 3)
- the contactor coil voltage and relay load
- whether there are high harmonics on site – if so, a cabinet with detuning reactors is required
Important reminder: A controller does not replace correctly selected capacitors and detuning reactors – if harmonics are high, a better controller alone will not solve the problem.FAQ
Does MASTER06 work with a single current transformer?
Yes, 1 or 3 CTs can be used; with three, unbalanced loads are measured more accurately.Is the current transformer included?
No, a CT with a /5 A or /1 A secondary is purchased separately according to the incoming supply current.Can it be connected to SCADA?
Yes, via the RS-485 port using the Modbus RTU protocol.What is the difference between MASTER06 and MASTER12?
Only the number of steps: MASTER06 has 6 steps, MASTER12 has 12.Does the controller measure harmonics?
Yes, it has built-in network analyser functions, including harmonic measurement.Can a different cos φ be set for night-time?
Yes, up to 4 cos φ targets can be set for different time periods.Disclaimer. This description is based on manufacturer data and is provided for information only. Final selection, connection and commissioning must be carried out by a qualified electrician in accordance with the site design and applicable requirements. UAB „Elektrotechnikos sprendimai“ accepts no liability for selection or connection carried out solely on the basis of this description.Lifasa MASTER06 – 6-step smart cos φ controller
Lifasa MASTER06 automatically controls 6 capacitor steps, measures via 1 or 3 CTs, monitors harmonics, temperature and leakage, and transfers data via RS-485 Modbus RTU. Suitable for new and retrofitted capacitor banks.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products