Temporary construction site distribution board | 40 A | with circuit breakers and residual current device | 1×CEE 400 V + 2×CEE 230 V sockets | metal | surface-mounted | 410×300×180 mm | IP44 | SKLS40
Code: SKLS40Price 163.35 € VAT incl.( 135.00 € VAT excl. )A 40 A metal surface-mounted construction site distribution board with installed circuit breakers, a residual current device and three industrial CEE sockets – one 3-phase 400 V (red) and two single-phase 230 V (blue). The enclosure has a door with a lock, IP44 protection.
-
Temporary construction site distribution board | 40 A | with circuit breakers and residual current device | 1×CEE 400 V + 2×CEE 230 V sockets | metal | surface-mounted | 410×300×180 mm | IP44 | SKLS40
A 40 A metal surface-mounted construction site distribution board with installed circuit breakers, a residual current device and three industrial CEE sockets – one 3-phase 400 V (red) and two single-phase 230 V (blue). The enclosure has a door with a lock, IP44 protection.
Key idea:
This is a ready temporary power point that only needs to be fixed to a wall and connected to the supply. The metal enclosure with a lockable door protects the devices against unauthorised persons and mechanical damage on site.Rated current
40 ASockets
1×CEE 400 V + 2×CEE 230 VProtection
circuit breakers + RCDEnclosure
metal, IP44How it works
The board is surface-mounted on a wall or structure and supplied from a 3-phase 230/400 V network. The supply cable is connected to the board inlet.
The installed circuit breakers protect socket groups against overload and short circuit, while the residual current device disconnects the supply in the event of earth leakage.
The result is a lockable metal distribution point supplying 3-phase and single-phase site equipment.
Why choose SKLS40?
Overcurrent and earth leakage protection are combined in one enclosure, so there is no need to buy and install separate devices. The metal enclosure with a lock suits locations where unauthorised persons may access the board.Technical specifications
Product type Temporary construction site supply / distribution board with sockets and protection Code SKLS40 Rated current 40 A Rated voltage 230/400 V Frequency 50 Hz 3-phase sockets 1× industrial CEE 400 V (red) Single-phase sockets 2× industrial CEE 230 V (blue) Protective devices circuit breakers (overload, short circuit), residual current device Enclosure metal, with door and lock Mounting surface-mounted Dimensions (H×W×D) 410 × 300 × 180 mm Degree of protection IP44 Main functions
- Circuit breakers – protect socket groups and cables against overload and short circuit.
- Residual current device – disconnects the supply in case of earth leakage and reduces the risk of electric shock.
- 3-phase CEE 400 V socket – for mixers, cutting machines and other 3-phase equipment.
- Two CEE 230 V sockets – for single-phase tools and lighting with industrial plugs.
- Lockable metal enclosure – protection against unauthorised persons and mechanical impact.
- IP44 – suitable for outdoor use on construction sites.
Where is it used?
- Residential construction sites
- Renovation projects
- Temporary lighting and tool supply
- Farms and seasonal work
- Temporary workshops
- Technical zones at events
Use by need
For the contractor.
A lockable board that can be left unattended on site.For the electrician.
A ready board with protection – only the supply needs to be connected.For the farm owner.
Safe temporary 3-phase and single-phase power for seasonal work.Practical application
If a house under renovation needs power for a concrete mixer and several single-phase tools and the site is left overnight, this board can be fixed to the wall, the equipment connected via CEE plugs and the door locked.Pros
- Circuit breakers and RCD already installed
- Metal enclosure with door and lock
- 3-phase and single-phase CEE sockets
- IP44 for outdoor conditions
- Compact surface mounting
Cons / limitations
- The single-phase sockets are CEE 230 V, so domestic Schuko plugs need an adapter
- Only one 3-phase socket
- Total load limited to 40 A
- The metal enclosure must be reliably earthed
Safety and installation notes
- Connection must be made by a qualified electrician; earth the enclosure.
- Select the supply cable cross-section and protection for a 40 A load.
- Test the RCD with the TEST button before work.
- Keep the door closed and locked when the board is left unattended.
- Do not connect equipment with damaged cables or plugs.
Quick selection guide
230/400 V40 A1×CEE 400 V2×CEE 230 VMCB + RCDmetalIP44surface-mountedSuitable when you need:- A lockable temporary site supply
- Ready protection without assembling a board
- 3-phase and single-phase power in one place
Check before use:- That the equipment plugs are CEE type
- That the total current does not exceed 40 A
- That the supply line and earthing match the board rated current
Important reminder: The board is not an energy metering board – if a meter is required on site, choose a metering board.FAQ
Does the board have an RCD?
Yes, it has installed circuit breakers and a residual current device.How many 3-phase sockets are there?
One industrial CEE 400 V socket.Can Schuko plugs be connected?
Not directly – the single-phase sockets are CEE 230 V, an adapter is needed.Is the enclosure lockable?
Yes, the metal enclosure has a door with a lock.What is the rated current?
40 A.Is it suitable outdoors?
Yes, the board has IP44 protection.Temporary construction site distribution board | 40 A | with circuit breakers and residual current device | 1×CEE 400 V + 2×CEE 230 V sockets | metal | surface-mounted | 410×300×180 mm | IP44 | SKLS40
SKLS40 – a 40 A metal temporary construction site board with circuit breakers, an RCD and CEE 400 V and 230 V sockets, a lockable enclosure and IP44 protection.
Published: 2026-11-15 · Data verified against the supplier specification: 2026-11-15
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.Mounting typeSurface mount typeThe IP protection class indicates the device's resistance to environmental factors.

The first digit indicates protection against dust and solid objects.
The second digit indicates protection against moisture.First digit values:
X — Untested;
0 — No protection;
1 — Protected against solid objects larger than 50 mm;
2 — Protected against solid objects larger than 12.5 mm;
3 — Protected against solid objects larger than 1 mm;
4 — Protected against solid objects larger than 1 mm;
5 — Dust protected;
6 — Totally dustproof.
Second digit values:X — Untested;
0 — No protection;
1 — Protected against vertically falling water drops;
2 — Protected against water drops falling at a 15º angle;
3 — Protected against rain falling at a 60º angle;
4 — Protected against water splashes;
5 — Protected against water jets;
6 — Protected against large amounts of water;
7 — Protected against short-term immersion in water up to 1 meter deep;
8 — Protected against long-term immersion in water up to 3 meters deep.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Three-phase electricity meter | 5(10) A via current transformers | 3×230/400 V | CT connection | 1 tariff | active energy | GAMA 300 | ELGAMA-ELEKTRONIKA G3A.147-230.C110Code: G3A.147-230.C110A Lithuanian-made three-phase active energy meter connected via x/5 A current transformers – for metering large supplies and feeders. Class B to EN 50470-3, 1 tariff, internal clock, LCD. Panel housing with three-point mounting.
Price 152.15 € VAT incl.( 125.74 € VAT excl. )CYKY-L 5G4 | 5×4 mm² | Copper power cable | 450/750 V | black | 1 m | LietkabelisCode: 91950413CYKY-L 5G4 (5×4 mm²) – 450/750 V copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. AB Lietkabelis, price per 1 m.
Price 3.45 € VAT incl.( 2.85 € VAT excl. )
















