
Three-phase voltage and phase monitoring relay | 3F | 220–460 V (L-L) | U> / U< | phase sequence | DIN | VEXEN | PCR3
Code: PCR3Price 39.59 € VAT incl.( 32.72 € VAT excl. )The VEXEN PCR3 is a three-phase network monitoring relay with an output contact for motors, pumps and automation panels.
-
Three-phase voltage and phase monitoring relay | 3F | 220–460 V (L-L) | U> / U< | phase sequence | DIN | VEXEN | PCR3
The VEXEN PCR3 is a three-phase network monitoring relay with an output contact for motors, pumps and automation panels. It detects phase loss and other network faults – depending on the model also wrong phase sequence, asymmetry or voltage deviations.
Key point:
The biggest dangers for a three-phase motor are a lost phase, wrong phase sequence or high asymmetry – the motor overheats or runs backwards. A monitoring relay disconnects the motor via a contactor before it fails.Voltage limits
U> +2…+20 % Un · U< −2…−20 % UnNetwork / supply
3FFunctions
phase sequence, asymmetryHow it works
The relay is connected to phases L1, L2, L3 (and N, depending on the model) and monitors network parameters according to the selected rated voltage Un.
When a fault is detected, the output contact switches over and disconnects the motor or other equipment via a contactor; short fluctuations are filtered by the delay.
When the parameters return to normal, the contact automatically returns to the operating state.
Why choose the VEXEN PCR3?
A compact way to protect a three-phase motor or pump against phase loss and other network faults.Technical specifications
Product type Three-phase voltage and phase monitoring relay (control type – with contact) Manufacturer / code VEXEN / PCR3 Rated voltage Un (selectable) 220 / 230 / 240 / 380 / 400 / 415 / 440 / 460 V (L-L) Measured voltage 176–552 V Frequency 45–65 Hz Overvoltage limit U> (factory) +2…+20 % Un Undervoltage limit U< (factory) −2…−20 % Un Phase asymmetry threshold 8 % Phase failure threshold 70 % Un Voltage trip delay 0.1–10 s Hysteresis 2 % Measuring accuracy ≤ 1 % Degree of protection IP40 / IP20 Operating temperature −20…+55 °C Dimensions 90 × 18 × 64 mm Weight 64 g Standards EN 60255-1, IEC 60947-5-1 Mounting DIN 35 mm Main functions
- Phase loss detection – the motor does not run on two phases.
- Overvoltage monitoring U> – reacts to excessive voltage.
- Undervoltage monitoring U< – reacts to low voltage.
- Phase sequence monitoring – the motor is not started with swapped phases.
- Asymmetry monitoring – reacts to unequal phase voltages.
- Phase loss monitoring – disconnects when a phase is lost.
Where is it used?
- Three-phase motors with contactor
- Borehole and drainage pumps
- Compressors, fans, conveyors
- Refrigeration equipment, refrigerated trucks
- Agricultural and construction site equipment
- Automation panels
Use by need
For the automation installer.
Phase monitoring in the contactor control circuit.For a farm or workshop owner.
The pump and compressor are protected against a lost phase.For the electrician.
A compact relay for the motor panel.Practical use
A borehole pump or compressor is controlled by a contactor. If one phase is lost or the phases are swapped after repairs, the VEXEN PCR3 prevents the motor from running – the contactor is disconnected.Pros
- Monitoring of phase loss and other faults
- Compact
- Suitable for contactor control
- DIN mounting
Cons / limitations
- High-power loads must be connected via a contactor
- Does not protect against lightning surges
- Does not replace a motor protection circuit breaker
Safety and installation notes
- Install only after disconnecting the supply; work must be done by a qualified electrician.
- Connect high-power loads only via a contactor.
- Check the phase sequence before start-up.
- Set the rated voltage Un according to the network.
Quick selection guide
3F220–460 V (L-L)U> / U<phase sequenceSuitable when you need:- to protect a three-phase motor or pump
- to monitor phase sequence and phase loss
Check before use:- the network voltage matches the relay's Un
- contactor coil current ≤ contact current
Important reminder: the relay does not replace a motor protection circuit breaker and a thermal overload relay.FAQ
Can a motor be connected directly through the relay?
No – via a contactor.Is a neutral needed?
Depends on the model – see the technical table.What does it protect against?
Phase loss and, depending on the model, wrong sequence, asymmetry or voltage deviations.Does it protect against lightning?
No – an SPD is needed for that.Does it reset automatically?
Yes, when the parameters return to normal.Does it replace a thermal overload relay?
No.Three-phase voltage and phase monitoring relay | 3F | 220–460 V (L-L) | U> / U< | phase sequence | DIN | VEXEN | PCR3
VEXEN PCR3 – protection of three-phase motors and pumps against phase loss and network faults.
Published: 2026-11-13 · Data verified against the manufacturer's datasheet: 2026-11-13
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Electrical distribution | modular enclosure | box | distribution board | 36 modules (2x18) | 432x448x161mm | transparent door | waterproof | surface-mounted | plastic | IP65 | Legrand | PLEXO | 601986 | 3245066019864Code: 601986Hermetic electrical distribution enclosure designed for the safe installation of modular electrical devices in both indoor environments and more demanding outdoor or industrial conditions. This is a high-quality IP65 protection class electrical box adapted to protect automation, protection, and electrical distribution equipment from dust, moisture, water splashes, and mechanical impact.
Price 87.95 € VAT incl.( 72.69 € VAT excl. )













