    Promfactor PF-FRV132 (FRV13 2) – three-phase voltage monitoring relay 208–480 V AC: phase sequence, phase loss, U>/U<, asymmetry 5–20 %, 1 C/O 8 A, for DIN rail.

  • Three-phase voltage monitoring and phase sequence relay | 3F | 208–480V AC | U>/U< | asymmetry 5–20% | 1 C/O 8A | DIN | IP20 | FRV13 2 | Promfactor Baltic | PF-FRV132

    PF-FRV132 (manufacturer designation FRV13 2) is a Promfactor Baltic three-phase voltage monitoring relay that monitors L1, L2, L3 voltage, phase sequence, phase loss and asymmetry. Selectable rated voltage 208–480 V AC (10 values), adjustable overvoltage (105–125 % Un) and undervoltage (75–95 % Un) limits, asymmetry 5–20 % and delays 0.1–10 s; output – 1 changeover contact 8 A/250 V (AC1), DIN rail mounting, IP20.

    Key idea:
    The relay is placed ahead of the control circuit of three-phase equipment and allows it to operate only when the network is healthy: correct phase sequence, all phases present, voltage within limits and phases not excessively unbalanced. When a fault occurs, the contact de-energises the contactor coil or signals the controller – the motor does not start in the reverse direction and does not run on two phases.
    Rated voltage Un
    208–480 V AC (10 values), 50/60 Hz
    Monitoring
    U>, U<, phase sequence, phase loss, asymmetry
    Output
    1 C/O, 8 A / 250 V (AC1)
    Installation
    DIN (TH35), IP20

    Operating principle

    The relay is mounted on a TH35 DIN rail, the phases of the monitored network are connected to terminals L1, L2, L3 (wires 0.5–2.5 mm², tightening torque 0.5 Nm), and the changeover contact is wired into the contactor coil or controller input circuit. The knobs are used to set the rated voltage Un, the overvoltage and undervoltage limits, asymmetry and delays.

    The relay continuously measures the three-phase voltage within the operating range of 165–528 V AC. If U> (105–125 % Un) is exceeded or the voltage drops below U< (75–95 % Un), the contact switches over after the set delay (adjustable 0.1–10 s or fixed 2 s); the asymmetry limit is adjustable 5–20 % or fixed 8 %. Incorrect phase sequence or phase loss disconnects the output within ≤0.5 s; hysteresis is fixed at 2 %.

    Result – a three-phase motor or other equipment is switched on only when the network is healthy and is switched off when a fault occurs until the parameters return to normal.

    Benefits PF-FRV132?
    A single 3-phase relay combines five protections – overvoltage, undervoltage, phase sequence, phase loss and asymmetry – with adjustable limits and delays and 10 rated voltage values from 208 to 480 V, making it suitable for 3 × 400 V as well as 3 × 230 V or 480 V networks.

    Technical specifications

    Product type Three-phase voltage monitoring and phase sequence relay
    Manufacturer / code Promfactor Baltic / PF-FRV132 (FRV13 2)
    Barcode 4772151003204
    Monitored phases L1, L2, L3
    Rated voltage Un 208 / 220 / 230 / 240 / 380 / 400 / 415 / 440 / 460 / 480 V AC
    Frequency 50/60 Hz
    Operating voltage range 165–528 V AC
    Overvoltage limit U> 105–125 % Un
    Undervoltage limit U< 75–95 % Un
    Asymmetry adjustable 5–20 % or fixed 8 %
    U> / U< delay adjustable 0.1–10 s or fixed 2 s
    Phase sequence / phase loss delay ≤0.5 s
    Delay tolerance ±10 % + 0.1 s
    Hysteresis fixed 2 %
    Setting knob tolerance 1 % of full scale
    Output contacts 1 C/O (changeover)
    Contact load AC1 8 A / 250 V
    Insulation voltage Ui 415 V
    Endurance, electrical / mechanical 10⁵ / 10⁶ cycles
    Wire cross-section 0.5–2.5 mm²; tightening torque 0.5 Nm
    Installation DIN rail TH35
    Degree of protection IP20
    Pollution degree 3
    Altitude above sea level up to 2000 m
    Operating temperature -5…+40 °C
    Storage temperature -10…+50 °C
    Standards EN/IEC 60730-1, EN/IEC 60730-2-7

    Main functions

    • Phase sequence monitoring – prevents a three-phase motor from starting in reverse after mains switching or repair.
    • Phase loss detection – disconnects the output within ≤0.5 s so that the motor does not run on two phases and overheat.
    • Overvoltage protection U> – the 105–125 % Un limit protects the equipment against increased voltage.
    • Undervoltage protection U< – the 75–95 % Un limit protects motors against overload during voltage drops.
    • Asymmetry monitoring – the limit, adjustable 5–20 % or fixed 8 %, detects phase imbalance.
    • Adjustable delays – 0.1–10 s or fixed 2 s – short voltage fluctuations do not cause nuisance tripping.
    • 10 rated voltage values – from 208 to 480 V – one model for various three-phase networks.
    • Changeover contact 8 A – 1 C/O is suitable for de-energising a contactor coil or sending a signal to a controller.
    • Hysteresis 2 % – the relay switches over stably and does not chatter at the limit.

    Where is it used?

    • Three-phase motors of pumping stations and borehole pumps
    • Compressors, refrigeration and heat pump equipment
    • Lifts, hoists, cranes and conveyors where the direction of rotation matters
    • Control panels of ventilation units and smoke extraction fans
    • Mobile and temporary sites supplied via plug-in connections or a generator
    • Farm and production workshop equipment in rural networks with voltage fluctuations
    • Industrial automation control panels as incomer power quality monitoring

    On-demand operation

    For pump and compressor installers.
    phase sequence and phase loss monitoring (≤0.5 s) protects the motor against running in reverse and on two phases.
    For the control panel manufacturer.
    10 rated voltage values from 208 to 480 V allow the same relay to be used in projects for different countries and networks.
    For farm or workshop energy engineers.
    adjustable U>/U< limits and asymmetry 5–20 % with a 0.1–10 s delay disconnect the equipment only in the event of a real network fault.

    Practical application

    If phases may be swapped or one of them lost in a 3 × 400 V borehole pump panel after grid works, then PF-FRV132 with Un = 400 V, U< 85 %, asymmetry 8 % and a 2 s delay will de-energise the contactor coil via its 8 A contact, and in the event of phase loss or a sequence change – within ≤0.5 s.

    Application guide: how it is used in practice

    PF-FRV132 can be adapted to different three-phase sites – only the settings and what the contact controls change:

    Site What is connected Result Installer's note
    Borehole or sewage pump L1, L2, L3 from the pump incomer; C/O contact to the contactor coil The pump does not start in the event of incorrect phase sequence or phase loss Set the delay to 2–5 s so that it does not react to short surges
    Compressor / refrigeration unit Incomer phases; contact in the control circuit Protection against undervoltage and asymmetry Set U< according to the voltage permitted by the compressor manufacturer
    Hoist or conveyor Motor circuit phases; contact to the safety circuit Reverse movement is not permitted Check the sequence after each cable or plug change
    Site with a generator Phases downstream of the changeover switch; contact to the controller input The controller receives a signal about the network quality Increase the delay if the generator voltage fluctuates
    Production workshop panel Incomer phases; contact to the alarm system or BMS Network faults are detected and signalled Set the asymmetry threshold according to the most sensitive equipment

    How to select a Promfactor voltage monitoring relay

    Network / monitored parameters Recommended model
    1-phase, 230 V, voltage monitoring FRV11 (single-phase voltage monitoring relay 230 V, 50/60 Hz)
    Voltage monitoring with digital setting FRV15 4 (digital voltage monitoring relay)
    3-phase, 208–480 V, U>/U<, phase sequence, phase loss, asymmetry PF-FRV132 (FRV13 2 – three-phase voltage monitoring relay, 1 C/O 8 A) ← this model
    1-phase, voltage and current, up to 63 A FRVA1S-63A (single-phase voltage and current monitoring relay)
    1-phase, voltage and current, up to 63 A FRVA1-63A (single-phase voltage and current monitoring relay)
    3-phase, voltage and current, up to 63 A FRVA3-63A (three-phase voltage and current monitoring relay)
    Rule: if you need to control a contactor or send a signal about the state of the three-phase network – choose PF-FRV132 (output – 1 C/O 8 A/250 V, not a power circuit); if a load up to 63 A must be disconnected directly while also monitoring current – FRVA series; for single-phase networks – FRV11 or FRVA1.
    When to choose another solution: for single-phase networks – FRV11; digital relay – FRV15 4; voltage and current monitoring with direct disconnection up to 63 A – FRVA1S-63A, FRVA1-63A, three-phase – FRVA3-63A; for motor starting with a thermal overload relay – SKM series motor starters in boxes.

    Pros

    • Five protections in one relay: U>, U<, phase sequence, phase loss, asymmetry
    • 10 rated voltage values from 208 to 480 V
    • Adjustable limits and delays 0.1–10 s or fixed
    • Fast response to phase loss and incorrect sequence – ≤0.5 s
    • Changeover contact 8 A / 250 V (AC1)
    • Mounting on a TH35 DIN rail

    Cons / limitations

    • Contact 8 A / 250 V – does not switch power circuits directly, a contactor is required; for direct disconnection up to 63 A – FRVA3-63A
    • Does not monitor current – motor overload requires a thermal overload relay or motor protection circuit breaker
    • Operating temperature only -5…+40 °C – not suitable for an unheated outdoor panel without heating
    • IP20 – install only in a closed panel

    Safety and installation notes

    • Installation and setting must be carried out only by a qualified electrician after disconnecting all three phases.
    • Monitored voltage – up to 480 V AC (operating range 165–528 V); insulation voltage Ui 415 V.
    • Protect the contact circuit with a suitable fuse or circuit breaker; do not exceed 8 A / 250 V (AC1).
    • Before switching on, check that the set Un matches the mains voltage.
    • Install in an enclosed control panel (IP20), operating temperature -5…+40 °C, altitude up to 2000 m.

    Quick selection guide

    3-phase
    208–480 V AC
    Phase sequence
    Asymmetry 5–20 %
    1 C/O 8 A
    DIN
    Suitable when you need:
    • protect a three-phase motor against incorrect phase sequence and phase loss;
    • disconnect equipment in the event of overvoltage, undervoltage or asymmetry;
    • transmit a network status signal to a controller or alarm system.
    Check before use:
    • the rated mains voltage – whether it is among the 208–480 V values;
    • the contactor coil or controller input load – whether it does not exceed 8 A / 250 V AC1;
    • the control panel temperature – whether it stays within -5…+40 °C.
    Important reminder: PF-FRV132 monitors mains voltage and phases, but not current – motor overload protection requires a separate thermal overload relay or motor protection circuit breaker.

    FAQ

    Which networks is PF-FRV132 suitable for?
    For three-phase 50/60 Hz networks with a rated voltage selectable from 10 values between 208 and 480 V AC.
    Does the relay monitor phase sequence?
    Yes, incorrect phase sequence or phase loss disconnects the output within ≤0.5 s.
    What are the overvoltage and undervoltage limits?
    The overvoltage limit is adjustable 105–125 % Un, the undervoltage limit 75–95 % Un.
    How is asymmetry set?
    The asymmetry threshold is adjustable from 5–20 % or a fixed value of 8 % is used.
    What contact does the relay have?
    One changeover contact (1 C/O) rated 8 A / 250 V AC1.
    Can the motor be disconnected directly via the relay?
    No, the contact is intended for a contactor coil or control signal; the power circuit is switched by the contactor.

    Three-phase voltage monitoring and phase sequence relay | 3F | 208–480V AC | U>/U< | asymmetry 5–20% | 1 C/O 8A | DIN | IP20 | FRV13 2 | Promfactor Baltic | PF-FRV132

    Promfactor Baltic PF-FRV132 (FRV13 2) – three-phase voltage monitoring and phase sequence relay 208–480 V AC with U>/U<, phase loss and 5–20 % asymmetry monitoring, delay 0.1–10 s, 1 C/O 8 A contact, for DIN rail – for protecting pumps, compressors and motors.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Terminal clamp | electrical wire connector | universal | 2x0.2-4mm² | for all wire types | WAGO | 221-412 | 4050821808435
    Code: WAGO 221-412

    The WAGO 221-412 connector is one of the most popular and reliable electrical wire connection solutions in the world. It is designed for fast, safe, and professional connection of various types of copper conductors without the need for additional tools.

    Thanks to the patented CAGE CLAMP® technology and convenient orange levers, this connector allows quick connection of solid, stranded, and flexible conductors. The transparent housing enables visual inspection of the connection quality, while its compact dimensions allow easy installation in junction boxes, distribution boards, luminaires, and various automation equipment.

    The WAGO 221 series is widely used in residential, commercial, and industrial applications where reliable, standards-compliant, and long-lasting wire connections are required. 

    Price 0.30 € VAT incl.
    ( 0.25 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information