Humidity controller | 0–99 % RH | direct output 10 A / 1500 W | 220 V AC | Taxnele XH-W3005
Code: ES-W3005-220Price 25.41 € VAT incl.( 21.00 € VAT excl. )XH-W3005 digital humidity controller with LED display and probe on cable: 0–99 % RH, 0.1 % RH setting step. Powered by 220 V AC, direct output up to 10 A / 1500 W – for humidifying or dehumidifying.
-
Humidity controller | 0–99 % RH | direct output 10 A / 1500 W | 220 V AC | Taxnele XH-W3005
The Taxnele XH-W3005 is a digital humidity controller module with an LED display and an external humidity probe on a cable. It measures relative humidity at 0–99 % RH and switches a humidifier, dehumidifier or fan on and off between two set points. Supply 220 V AC, direct output up to 10 A / 1500 W.
Key point:
A simple way to automate a small humidifier or fan without a separate controller or programming. The output is not a dry contact: when the relay closes, the same mains voltage that powers the module is passed to the load. Supplier limit is 1500 W; inductive loads need a contactor.Measuring range
0–99 % RHSetting step
0.1 % RHSupply
220 V ACMax. load
10 A / 1500 WHow it works
The module is fixed in a closed enclosure or panel, and the probe cable is routed into the controlled space. Mains voltage goes to the 2 power terminals via a circuit breaker, the load to the 2 output terminals. Wiring by a qualified electrician.
UP sets the switch-on point, DOWN the switch-off point: hold for about 3 s until the value flashes, then adjust in 0.1 % RH steps. If the switch-on point is lower than the switch-off point, the controller humidifies; if higher, it dehumidifies.
The gap between the two points works as hysteresis, so small fluctuations do not cause rapid switching. Humidity stays within your set band without manual intervention.
Why choose the XH-W3005?
One small module replaces manual control of a mains humidifier or fan. Actual humidity is always on the display, set points change with two buttons, and larger loads are switched via a contactor.Technical specifications
Product type Digital humidity controller (hygrostat), open module Manufacturer / model Taxnele XH-W3005 (ES-W3005-220) Measured value Relative air humidity (no temperature measurement) Measuring range 0–99 % RH Measuring accuracy ±2 % RH (according to supplier data) Setting step 0.1 % RH Supply voltage 220 V AC (suppliers state 110–220 V AC) Output type Direct: the relay passes the supply voltage to the load (not a dry contact) Max. load 10 A relay, up to 1500 W (supplier limit) Modes Humidify / dehumidify – set by the relation of switch-on and switch-off points Display / control LED display, 2 buttons (UP / DOWN) Probe External humidity probe on cable, approx. 1 m (according to supplier data) Dimensions 60 × 45 × 31 mm Mounting hole spacing 73 mm Weight approx. 65–68 g Housing Open board type, no IP rating – install in an enclosure or panel Main functions
- Humidify and dehumidify modes – the mode follows from which set point is higher; no separate menu.
- Two separate set points – switch-on and switch-off values are set independently, so you choose the band (hysteresis).
- 0.1 % RH setting step – set points can be set precisely.
- LED display – shows actual relative humidity, and the set points while adjusting.
- External probe on cable – measures where needed while the module stays in a dry enclosure.
- 10 A direct output – supply voltage is passed to the load without an extra relay (up to 1500 W).
- Factory reset – UP and DOWN together, display shows “888”.
How does it differ from similar products?
STC-3028 (21501–21503) Measures and controls both temperature and humidity with two separate outputs. The XH-W3005 controls humidity only but is simpler and more compact. Plastim PHG02 (531) Mechanical DIN-rail hygrostat, 10–90 % RH, 10 (5) A contact, no display and no probe on cable. The XH-W3005 shows humidity digitally and measures via a probe. SONOFF SNZB-02DR2 (18621) Wireless Zigbee T/RH sensor with LCD, no relay output – control only via a Zigbee hub. The XH-W3005 works standalone and switches the load itself. Other XH-W3005 versions Same module, different supply and load limit: 12 V DC – up to 120 W (20484) and 24 V DC – up to 240 W (20485). Choose the version by load voltage. Where is it used?
- Greenhouses and seedling rooms – ultrasonic humidifier
- Mushroom growing rooms and boxes
- Incubators and hatching boxes
- Cellars and storerooms – extract fan or dehumidifier (via contactor)
- Terrariums and paludariums
- Electrical panels – switching a heater or fan on at high humidity
- Small drying and storage rooms
Use by need
For beginners.
Just connect supply and load and set two points. For humidifying, the switch-on point is lower and the switch-off point higher, e.g. 55 and 65 % RH.For experienced installers.
The output carries mains voltage, not a dry contact. For motors, compressors and larger loads use a contactor – the module then drives only the coil.For engineers / designers.
Accuracy ±2 % RH, no calibration, delay or communication interface. Suited to local ON/OFF control; for BMS or Modbus integration choose Sentera sensors/transmitters from the same group.Practical application
Situation: in a greenhouse seedling room, humidity drops to 40 % RH during the day. Solution: XH-W3005 220 V AC version with an ultrasonic humidifier, switch-on at 55 % RH, switch-off at 65 % RH (humidify mode). Result: the humidifier starts automatically, and humidity stays within 55–65 % RH without manual intervention.Pros / advantages
- Only two set points – set up in a minute, no menu.
- Humidifying and dehumidifying with one module.
- Direct output – no extra relay needed for a small humidifier or fan.
- Probe on cable – the module stays in a protected enclosure.
- 0.1 % RH setting step and clear LED reading.
- Compact: 60 × 45 × 31 mm.
Cons / limitations
- Measures humidity only – no temperature control. For both values choose the STC-3028.
- The output is not a dry contact – it cannot directly control a circuit of a different voltage.
- No calibration, delay or minimum off-time – for compressor dehumidifiers set a wider band and use a contactor.
- Open board-type housing with no IP rating – only inside an enclosure or panel.
- Accuracy ±2 % RH, no communication interface. For integration choose Sentera Modbus sensors.
Safety and installation notes
- ⚡ Installation by a qualified electrician only. Disconnect the supply before work and verify it is dead.
- ⚡ The board is open – terminals and tracks are at mains voltage. Install the module only in a closed, non-conductive enclosure or panel so it cannot be touched.
- ⚡ Protect the circuit with a circuit breaker of up to 10 A and, where installation rules require it, a 30 mA residual current device.
- ⚡ The output carries mains voltage. Do not apply power while the output is unconnected or wired incorrectly (supplier warning).
- ⚡ Use a contactor for motors, compressors and larger loads. The supplier recommends not exceeding 50 % of the maximum values in continuous operation.
- ☝ Not in bathroom zones 0–2 (HD 60364-7-701). Do not immerse the probe in water and protect it from splashes.
Quick selection guide
Measures: humidity only, 0–99 % RHSupply: 220 V ACOutput: direct, 10 A / 1500 WMounting: in enclosure or panelSuitable when you need:- to keep humidity within a set band automatically
- to control a small humidifier or fan
- simple ON/OFF control without programming
- to measure humidity away from where the module is mounted
Check before choosing:- Does the load stay within 1500 W?
- Is a contactor planned for inductive loads?
- Will a qualified electrician install it?
- Do you have a closed enclosure or panel for the module?
Important reminder: ⚡ The output carries mains voltage, not a dry contact. The module does not control temperature and has no protective housing – closed enclosure only.☝ Elsprendimai.eu recommends:- Digital thermostat-hygrostat STC-3028 – STC-3028 – when you need to control both temperature and humidity with two outputs.
- Plastim PHG02 – Plastim PHG02 – mechanical DIN hygrostat for panels, no display.
- Temperature and humidity sensor selection guide – Group selection guide – sensors, transmitters and hygrostats in one place.
- Contactors and relays – Contactors and relays – for inductive and larger loads.
FAQ
Does the XH-W3005 measure temperature?
No. The module measures and controls relative humidity only. It is sometimes wrongly called a temperature and humidity controller.How do I set humidifying or dehumidifying?
There is no separate mode. If the switch-on point (UP) is lower than the switch-off point (DOWN), it humidifies; if higher, it dehumidifies.Is the output a dry contact?
No. It is a direct output: when the relay closes, the mains voltage that powers the module is passed to the load.Why 1500 W if the relay is 10 A?
1500 W is the supplier's maximum load for the 220 V AC version. For continuous operation the supplier recommends not exceeding 50 % of the maximum values.Can the reading be calibrated or a delay set?
Supplier data shows no calibration, delay or set-point limit functions. Only a factory reset is available (UP and DOWN together, “888”).How long is the probe cable?
According to supplier data, approx. 1 m. Plan the module position within this distance from the measuring point.Sources: XH-W3005 supplier product descriptions (Sigmanortec, bbiri-centre, ManoMano, Riverwood, Reptile Garden, AideePen). Checked 2026-10-19.
Humidity controller Taxnele XH-W3005 220 V AC
The Taxnele XH-W3005 220 V AC is a digital humidity controller with a probe on cable: 0–99 % RH, 0.1 % RH step and a 10 A / 1500 W direct output. It controls humidifiers, dehumidifiers and fans, with the module installed in an enclosure or panel.
Published: 2026-10-19 · Data verified against the supplier's data: 2026-10-19
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
IP surveillance camera | Turret | 4 MP | 2.8 mm | IR 30 m | WDR 120 dB | PoE | IP66 | Hikvision DS-2CD2345FWD-ICode: DS-2CD2345FWD-IHikvision DS-2CD2345FWD-I is a 4 MP (2688 × 1520) turret camera with a 1/2.5" sensor, 120 dB WDR and IR up to 30 m. Line-crossing, intrusion and unattended-object detection, H.265+, PoE 802.3af, microSD up to 128 GB, IP66.