Product Catalog
- Security and Surveillance Systems | accessories
- Lighting solutions for industrial | commercial | residential | outdoor environments | accessories
-
Automation and Control Systems
- Automation control accessories
- Control components for automation and control systems
- Signal converters | controllers for automation control | for control systems
- Touchscreens | panels for automation control | control systems
- Automatic Circuit Breakers for Direct Current (DC) Circuits with Integrated Overload, Short-Circuit, and Voltage Stabilization Protection Functions
-
Automation and Electrical Control Components | Contactors | Relays | SSR | Accessories
- Mini contactors for electric motor control
- Contactors | Electrical starters | For equipment control
- Electronic solid-state (SSR) contactors
- Contactors with enclosure and control buttons | for electrical equipment control
- Electromechanical thermal relays | electrical equipment protection
- Control coils for contactors | starters | electrical equipment control
- Adapters-converters for relays and contactors
- Additional contacts | Accessories for contactors
- Modular impulse relays | lighting | electrical circuit control
- Industrial solid state relays | electrical load control
- Intermediate relays for automation | for PLC and electrical control panels
- Automation control | Data transmission | Low current
- Industrial measurement | counting | detection systems for conveyors
- Panel heaters | protection for electrical equipment against moisture and cold
- Converters-transformers from single-phase to three-phase voltage
- Silicone strip heaters | electric heating solutions for industry
- Heating elements for liquids | water | oils | food heating
- Heating elements | igniters | for stoves | boilers | heaters
- Insulation Monitoring & Power Supply Equipment for Medical IT Systems
- Smart Automated Products | Control | Transmission | Detection
- Electrical distribution and installation
- Solar Energy Generation and Management Equipment
- HVAC control solutions for heating and ventilation
- Accessories for cars
- Workplace Safety | Electrical Safety Equipment | LOTO
- Technical maintenance | service equipment | fire protection solutions
- Emergency safety | hygiene | sanitary solutions
- Other products
- Quality used products
Automation and Electrical Control Components | Contactors | Relays | SSR | Accessories
-

Not sure which contactor, thermal overload relay or SSR you need? The selection guide gives you a 30-second table for motors up to 45 kW, categories AC-1 / AC-3, the thermal overload relay setting and the SSR cooling calculation. -
Read more
Contactor, relay and SSR guide: utilization category AC-1 / AC-3, coil voltage, thermal overload relay and solid-state relays
This guide gives you quick contactor selection by motor power and load type, five solution levels from a modular contactor to an enclosed motor starter, an explanation of utilization categories AC-1 / AC-3 / AC-7a and the selection rules for thermal overload relays and SSRs with a calculation. It also contains a matrix of all products in the group, a checklist, wrong-solution diagrams and practical questions and answers. The group includes mini and power contactors up to 400 A, reversing contactors, modular contactors for DIN rail, enclosed motor starters with push buttons, thermal overload relays, control coils, auxiliary contacts and interlocks, impulse (latching) relays, solid-state relays (SSR), interface relays, sockets and relay modules. Exact parameters are given in each product description.
Colour key: ■ information · ■ benefit, solution · ■ ⚠ check · ■ ⚡ safety, mistakes
Contents: In 30 seconds · Solution levels · What do you need? · How it works · Selection rules · Calculation · Selection matrix · What to check · Mistakes · Wrong solutions · Faults and fixes · FAQ · Related guides · Sources☝ ELSprendimai recommends: selection in 30 seconds →
Know the motor power or the load current? The table shows the contactor and thermal overload relay straight away.Selection in 30 seconds: contactor and thermal overload relay for a 400 V three-phase motor
Find the row that matches the motor power. The rated current is indicative (4-pole motor, 400 V) – take the exact value from the motor rating plate. The contactor is selected by its AC-3 current, the thermal overload relay so that its setting range covers the motor In.
Motor 400 V In ≈ AC-3 contactor and thermal overload relay in the group up to 2.2 kW 5 A contactor 6 A · 7 A; relay 4.5–6.5 A 3–4 kW 6.5–8.5 A contactor 9 A · 9 A; relay 6–8.5 A · 7.5–11 A 5.5 kW 11 A contactor 12 A · 12 A; relay 10–14 A 7.5 kW 15 A contactor 16 A · 18 A; relay 13–19 A 11 kW 22 A contactor 25 A, coil 100–250 V AC/DC · 25 A; relay 18–25 A 15 kW 29 A contactor 32 A · 32 A; relay 24–32 A 18.5 kW 35 A contactor 38 A · 38 A; relay 29–42 A 22 kW 42 A contactor 50 A · 50 A; relay 36–52 A 30 kW 57 A contactor 65 A; relay 45–63 A 37 kW 70 A contactor 80 A; relay 60–80 A 45 kW 84 A contactor 95 A; relay 80–93 A Rule: the contactor AC-3 current ≥ motor In; the thermal overload relay is set exactly to the motor In from the rating plate. The thermal overload relay must fit a contactor of the same series (or via an adapter frame). Short-circuit protection requires fuses or a circuit breaker – see the fuse guide.Solution levels: from a modular contactor to an enclosed motor starter
Each next level is designed for a heavier load or adds protection. Choose the level by the load, not by price.
Level 1. Modular contactor in the panel
Heating, water heater, lighting, tariff switching at home.- modular contactors 2P / 4P, 16–63 A
- models with manual control for servicing
Level 2. Mini contactor
Control cabinets, small pumps and fans up to 7.5 kW.- mini contactors 6–16 A
- 24 V DC coil directly from a PLC
Level 3. Power contactor + thermal overload relay
Pumps, compressors, conveyors 4–200 kW.- power contactors AC-3 9–400 A
- thermal overload relay matched to motor In
Level 4. Enclosed motor starter
Standalone motor in a workshop or on a farm, no panel.- starter with relay and push buttons IP54
- reversing – rotation in both directions
Level 5. SSR for frequent switching
Heating elements with a PID controller, extruders, furnaces.- solid-state relays with heat sink
- current margin ×2
What do you need? Quick selection
Situation Solution Where to look Switch a three-phase motor on and off AC-3 power contactor + thermal overload relay; or a ready-made enclosed motor starter Contactors, thermal overload relays, starters The motor must run in both directions Reversing contactor with mechanical and electrical interlock reversing mini 9 A, reversing starter, interlocks Electric heating, water heater, heating cable Modular contactor rated AC-1 / AC-7a; for frequent control – SSR Modular, SSR Lighting groups controlled from several places Impulse (latching) relay; for large groups – modular contactor Impulse relays, staircase relay guide A PLC output must control a larger load Interface relay or a contactor with a 24 V DC coil and surge suppressor Interface relays, interface relay guide Temperature controller with PID or SSR output DC–AC solid-state relay with heat sink SSR relays A contactor coil has burnt out Control coil of the same series and voltage Control coils More signalling contacts are needed Top- or side-mounted auxiliary contacts Auxiliary contacts Switching capacitor stages Special capacitor contactors with pre-charge resistors Compensation guide How it works: contactor, relay and SSR
A contactor is an electromagnetic switch: the control coil pulls in the armature and closes the main contacts. It is designed to switch a load frequently, but it does not protect against overload or short circuit – that requires a thermal overload relay and a fuse or circuit breaker. A solid-state relay (SSR) switches with semiconductors: no sparks and no wear, silent and fast, but it heats up and, when off, lets a small leakage current through.
AC-3motorsSquirrel-cage motors: starting and switching off while running. The main category for motor contactors.AC-1resistiveHeaters and slightly inductive loads (cos φ ≥ 0.95). The current is higher than AC-3.AC-7a / AC-7bhouseholdFor modular contactors (IEC 61095): AC-7a – household resistive loads, AC-7b – household motors.SSRcontactlessFrequent switching, PID control, silent operation. Requires cooling and a current margin.Feature Modular contactor Mini / power contactor Enclosed motor starter SSR Typical load heating, lighting motors, pumps standalone motor heating elements Category AC-7a / AC-1 AC-3, AC-1 AC-3 with thermal overload relay AC-51 (resistive) Current 16–63 A 6–400 A 0.1–95 A 10–120 A Mounting DIN rail, 18 mm modules DIN rail or mounting plate wall-mounted IP54 heat sink or mounting plate Switching life medium high (mechanical) high unlimited (no contacts) Isolation galvanic galvanic galvanic no – leakage current ⚡ Safety. An SSR that is off does not isolate the circuit: voltage remains on the load terminals and a leakage current of a few mA flows. Before working, isolate the line with a circuit breaker or switch disconnector. A contactor is not a disconnector either – it does not provide safe isolation for repairs.Selection rules: 6 steps
1. Utilization category by load
For motors – the AC-3 current (AC-4 for frequent inching or reversing while running). For heating – AC-1. For modular contactors – AC-7a (heating) and AC-7b (motors). For LED lighting, take the high inrush current into account – see the manufacturer’s lamp tables or choose with a margin.2. Current and power
Contactor AC-3 current ≥ motor In from the rating plate. For a 400 V motor the indicative current is about 2 A per kW. For a resistive three-phase load I = P / (√3 × 400 V): 9 kW ≈ 13 A.3. Coil voltage and type
The coil voltage must match the control circuit: 24 V AC, 24 V DC, 230 V AC or 400 V AC. AC and DC coils are not interchangeable (except universal AC/DC coils). When driving from a PLC, fit a surge suppressor (RC or varistor).4. Auxiliary contacts and interlocks
Signalling or a self-holding (latching) circuit requires NO / NC auxiliary contacts. For reversing – a mechanical interlock and an electrical interlock via NC contacts.5. Thermal overload relay
The range must cover the motor In, the setting – exactly In (not the maximum). Class 10 – for normal starting; for heavy starting (fans with a high moment of inertia) – class 20. The relay must fit the contactor series.6. SSR margin and cooling
SSR current – 1.5–2 times the load current. Every ampere produces about 1–1.5 W of heat, so from ~10 A a heat sink is essential. Control type: DC–AC (3–32 V DC control), AC–AC or DC–DC. For a resistive load – zero-cross switching.Calculation: 7.5 kW motor and a heater with an SSR
The two most common examples: direct-on-line starting of a three-phase motor and a single-phase heating element with a temperature controller.
Step Calculation Result Motor 7.5 kW, 400 V, In from the rating plate 15 A on the plate In = 15 A AC-3 contactor ≥ 15 A 16–18 A Thermal overload relay range covers 15 A 13–19 A, set to 15 A Heater 3 kW, 230 V I = 3000 / 230 13 A SSR current with margin 13 A × 2 25–40 A SSR heat 13 A × ~1.2 W/A ≈ 16 W → heat sink Conclusion: for the 7.5 kW motor – an 18 A contactor and a 13–19 A thermal overload relay set to 15 A. For the 3 kW heater – a 40 A SSR with heat sink or a 40 A SSR on a separate heat sink. Short-circuit protection is selected separately – fuse guide, circuit breaker guide.Selection matrix: all products in the group
Choose a situation – the matching rows will be highlighted:
Product Type Key data When to choose Note Mini contactors 6 · 9 · 12 · 16 A mini contactor 3P coil 230 V AC; 2.2–7.5 kW control cabinets, small motors 7 · 9 · 12 · 16 A · 9 A, 24 V DC · 16 A, 24 V DC mini contactor S00 (Siemens) coil 230 V AC or 24 V DC PLC-controlled motors 6 · 9 · 12 · 16 A reversing mini contactor with interlock; coil 230 V AC rotation in both directions 12 A, 24 V DC · reversing 9 A, 24 V DC mini contactor with DC coil coil 24 V DC directly from a PLC output with surge suppressor Power contactors 18 · 25 · 32 · 50 · 80 · 100 · 200 · 400 A AC-3 power contactor IEC 60947-4-1; various coils pumps, compressors, conveyors coil voltage – in the product name 32 · 38 · 50 · 65 · 95 A power contactor (Siemens) coil 230 V AC industrial motors 25 · 38 · 40 A power contactor (ABB AF) universal coil 100–250 V AC/DC unstable control voltage 4P, AC-1 20 A 4-pole contactor coil 230 V AC heating, switching Enclosed motor starters 0.25–15 kW · 4 kW · 18.5 kW, IP54 · 45 kW, IP54 starter with thermal overload relay and push buttons ready-made kit standalone motor without a panel relay range – to match the motor 0.37 · 0.75 · 2.2 · 3 kW enclosed reversing starter with thermal overload relay and push buttons rotation in both directions Thermal overload relays 4.5–6.5 · 6–8.5 · 7.5–11 · 10–14 · 13–19 · 18–25 · 24–32 A thermal overload relay up to 32 A 1NO + 1NC; mounts on the contactor motors up to 15 kW fits contactors of the same series 29–42 · 36–52 · 45–63 · 60–80 · 80–93 A thermal overload relay up to 93 A 1NO + 1NC motors 15–45 kW adapter frames – sold separately Modular contactors and impulse relays 2P 16 A · 2P 25 A · 4P 25 A · 4P 40 A · 4P 63 A modular contactor coil 230 V AC; DIN heating, water heater, lighting 2P 25 A · 2P 25 A modular with manual control AUTO / 0 / 1 selector servicing, emergency control 2P 20 A, 24 V AC · 2P 25 A, 24 V AC modular with 24 V coil coil 24 V AC thermostats, BMS 2 CO, with memory · 1P 16 A · electronic, 16 A impulse (latching) relay push-button control lighting from several places Solid-state relays (SSR) 10 · 25 · 40 · 60 · 80 · 120 A SSR DC–AC, 1-phase control 3–32 V DC; 24–480 V AC PID controllers, heating heat sink required 25 · 40 · 60 · 100 A SSR DC–AC with heat sink LED indication quick installation without a separate heat sink 25 · 40 · 25 A, sealed SSR AC–AC AC voltage control control by a 230 V signal 25 · 25 · 25 A SSR DC–DC load up to 60–200 V DC DC motors, valves, LEDs Accessories and repair control coils 24–400 V contactor coil same series replacing a burnt-out coil 1NO+1NC · 1NO · 1NO · 2NO+2NC auxiliary contacts top- or side-mounted signalling, self-holding circuit to match the contactor series 16 A · 63–125 A · AF09–AF38 mechanical interlock for reversing assemblies reversing, mains / generator 12–250 V · 24–48 V · 12–225 V DC surge suppressor RC or varistor for the coil protection of PLCs and electronics interface relays · sockets · relay modules control relays 6–10 A contacts signal amplification All products in the group – mini contactors, power contactors, enclosed motor starters, thermal overload relays, modular contactors, impulse relays, SSR, SSR contactors, coils, accessories and adapters.
⚠ What to check before buying
- Load type: motor (AC-3), heating (AC-1 / AC-7a), lighting or a DC load.
- The motor rated current from the rating plate – not just the power in kW.
- Coil voltage and type: 24 V AC, 24 V DC, 230 V AC, 400 V AC.
- Number of auxiliary contacts: NO / NC for signalling and a self-holding circuit.
- Thermal overload relay range and compatibility with the contactor series.
- For reversing – mechanical and electrical interlock.
- SSR – control signal (DC or AC), current margin ×1.5–2 and a heat sink.
- Mounting: DIN rail, mounting plate or IP54 enclosure; space in the panel.
✗ The most common mistakes
Mistake Consequence and how to avoid it A motor switched by a modular contactor sized on its AC-1 current The starting current welds the contacts. For motors – an AC-3 contactor. Thermal overload relay set to maximum The motor overheats without tripping. Set it exactly to the motor In. Contactor without short-circuit protection A short circuit welds the contacts or destroys the contactor. Upstream of it – fuses or a circuit breaker. 230 V AC coil connected to 24 V DC (or vice versa) The contactor does not pull in or the coil burns out. Coil – to match the control voltage. Reversing without an interlock ⚡ Both contactors close together – phase-to-phase short circuit. Mechanical + electrical interlock. SSR without a heat sink Overheats and fails within a few minutes. Heat sink and current margin. SSR treated as safe isolation ⚡ An SSR that is off passes leakage current, voltage on the terminals. For repairs – isolate with a circuit breaker. PLC output without a surge suppressor Coil overvoltages damage PLC outputs. RC or varistor surge suppressor. Wrong solutions: wrong and correct
⚠ The diagrams are illustrative. They are not wiring diagrams. Control and power circuits must be selected and installed by a certified electrician according to the design and the manufacturer’s instructions. UAB „Elektrotechnikos sprendimai“ accepts no liability for the connection or installation of equipment.1. Contactor for a motor: AC-1 or AC-3
Diagram. A modular contactor is designed for a resistive (AC-1) or household (AC-7a) load – the motor starting current (6–8 In) can weld its contacts. For a motor – an AC-3 contactor with a thermal overload relay and short-circuit protection upstream of it.
2. Thermal overload relay setting
Diagram. The thermal overload relay is set exactly to the motor rated current from the rating plate. If it is set to maximum, a sustained overload is not tripped and the motor windings overheat.
3. SSR cooling
Diagram. The SSR semiconductor dissipates about 1–1.5 W of heat per ampere. Without a heat sink a 13 A load produces ~16 W and the relay overheats; on a heat sink with vertical fins the heat is dissipated.
Faults and fixes: symptom → cause → what to do
Symptom Likely cause What to do The contactor hums and vibrates Coil voltage too low, dirty magnetic core Check the control voltage, clean or replace the contactor Contacts welded, the motor does not switch off Contactor undersized (not AC-3), short circuit Replace with a larger AC-3 unit, check the short-circuit protection The thermal overload relay trips frequently Overload, phase loss, setting too low Measure the current, check the phases, set to In Burnt-out coil Wrong voltage, AC coil in a DC circuit Coil to match the control voltage and type The SSR does not switch off Semiconductor broken down after overheating or a short circuit Replace the SSR, add a heat sink and a current margin An LED lamp glows when the SSR is off SSR leakage current Choose a contactor or an interface relay for small LED loads Frequently asked questions
Kibirkštis asks – a young, curious electrician who dares to ask what others won’t. Fazė answers – an experienced engineer.
Kibirkštis
What is the difference between AC-1 and AC-3?
Fazė
AC-1 – a resistive load, e.g. heaters: the contacts switch the rated current. AC-3 – motors: the contacts withstand a starting current 6–8 times higher. The same contactor can have an AC-1 current up to twice its AC-3 current.
Kibirkštis
Can I use a modular contactor for a pump?
Fazė
Only for a small single-phase or three-phase motor, if the manufacturer states an AC-7b or AC-3 current. For most motors a standard contactor with a thermal overload relay is a better choice.
Kibirkštis
How do I set a thermal overload relay?
Fazė
Exactly to the motor rated current from its rating plate. For example, for a 7.5 kW motor with 15 A – a 13–19 A relay set to 15 A.
Kibirkštis
When should I choose an SSR and when a contactor?
Fazė
SSR – when there are many switching operations (PID, pulse control) and silence and long life are needed. Contactor – for motors, when galvanic isolation is needed and there is no room for cooling.
Kibirkštis
Why does an SSR need a heat sink?
Fazė
The semiconductor has a voltage drop of about 1–1.6 V, so about 1–1.5 W of heat is released per ampere. For a 25 A load that is about 30 W; without a heat sink the relay overheats.
Kibirkštis
Can a 24 V DC coil be connected directly to a PLC?
Fazė
Only if the PLC output current is sufficient for the coil power. More often an interface relay is used, and the coil gets a surge suppressor.
Kibirkštis
Does a contactor protect the motor?
Fazė
No. A contactor only switches. The thermal overload relay protects against overload, and fuses or a circuit breaker against short circuit.Related guides
The control circuit also needs protection, relays, cables and a panel – these guides will help you choose them:- Fuse and fuse switch disconnector guide – short-circuit protection upstream of the contactor
- Circuit breaker guide – circuit protection
- Interface relay guide – signal amplification from PLCs and controllers
- Staircase lighting relay guide – push-button lighting control
- Phase monitoring relay guide – motor protection against phase loss
- Reactive power compensation guide – capacitor contactors
- Cable selection guide – motor and control cables
- All product selection guides
Sources
Standards and manufacturer data used in this guide.
- IEC 60947-4-1 – Contactors and motor starters: utilization categories AC-1, AC-3, AC-4
- IEC 60947-4-3 – Semiconductor controllers and contactors for non-motor loads (AC-51)
- IEC 61095 – Electromechanical contactors for household purposes (AC-7a, AC-7b)
- IEC 60947-5-1 – Control circuit devices and switching elements
- Manufacturer technical data in the product descriptions – contactors, thermal overload relays, SSRs
Published: 2026-11-04 · Data checked against manufacturer specifications: 2026-11-04
Disclaimer. This guide, its diagrams and calculations are for information only – they are not a design, wiring diagram or installation instructions. Contactors, relays and SSRs must be selected, connected and commissioned by a qualified, certified electrical professional in accordance with the design, the manufacturer’s instructions and applicable legislation. UAB „Elektrotechnikos sprendimai“ accepts no liability for the selection, connection, installation or operation of equipment based on this guide, or for any resulting damage.