  • Single-phase voltage relay | 1F | 63 A | U> 230–300 V | U< 160–210 V | DIN | ESYRVP-4

    Code: ESYRVP-4

    The ESYRVP-4 is a single-phase digital voltage relay for DIN-rail mounting in a distribution board.

  • Single-phase voltage relay | 1F | 63 A | U> 230–300 V | U< 160–210 V | DIN | ESYRVP-4

    The ESYRVP-4 is a single-phase digital voltage relay for DIN-rail mounting in a distribution board. The full load of the protected circuit passes through its contact, so it directly disconnects an apartment, a house circuit or a single appliance. When the voltage leaves the set limits, the relay disconnects the load and reconnects it once the voltage is back to normal.

    Key point:
    A broken neutral in a three-phase supply or a sustained over- or undervoltage is the most common cause of damage to expensive appliances. A power relay disconnects such voltage before boiler electronics, a fridge or a computer are harmed.
    Load current
    63 A
    Voltage limits
    U> 230–300 V · U< 160–210 V
    Network / supply
    1F, 230 V AC, 50/60 Hz
    Functions
    U> / U<, auto reconnect

    How it works

    The relay is installed after the main circuit breaker: phase and neutral to the input, the protected load to the output. A microcontroller continuously measures the mains voltage and shows it on the display.

    When the voltage leaves the set U> / U< limits, the load is disconnected after the set delay.

    When the parameters return to normal, the load is reconnected after the set delay. For compressors set a delay of at least 3 min.

    Why choose the ESYRVP-4?
    One power relay protects all appliances connected after it against a broken neutral and voltage fluctuations, without an additional contactor.

    Technical specifications

    Product type Single-phase digital voltage relay (power type – load through the relay)
    Manufacturer / code ESYRVP-4
    Network 1F, 230 V AC, 50/60 Hz
    Rated current 63 A
    Overvoltage limit U> (factory) 230–300 V
    Undervoltage limit U< (factory) 160–210 V
    Display / indication LED
    Operating temperature −25…+55 °C
    Mounting DIN 35 mm

    Main functions

    • Power relay – the full load passes through the relay, no additional contactor needed.
    • Over- and undervoltage protection – appliances are disconnected when the neutral breaks or the network fails.
    • Digital display or indication – the status is visible at once.

    Where is it used?

    • Apartment and house supplies (after the main circuit breaker)
    • Boiler and heat pump electronics
    • Fridges, freezers, air conditioners
    • Country houses with a weak network
    • Offices, servers, security systems
    • Rental properties and unattended sites

    Use by need

    For the home or apartment owner.
    One device protects all appliances against a broken neutral and voltage surges.
    For the electrician.
    Simple installation after the main circuit breaker, limits set with buttons.
    For the country house owner.
    On a weak network the real voltage is visible and equipment does not cycle needlessly.

    Practical use

    A house has a three-phase supply with single-phase equipment distributed among the phases. If the neutral contact burns out, the voltage on one phase rises to 300–380 V – the ESYRVP-4 disconnects the load before the boiler controller and power supplies burn out, and after the neutral is restored the equipment is switched on after the set delay.

    Pros

    • Full load through the relay
    • Adjustable limits and delays
    • Automatic reconnection
    • Compact DIN housing

    Cons / limitations

    • Does not protect against lightning and short surges – an SPD is needed
    • Does not replace a circuit breaker or RCD
    • Single-phase – a three-phase house needs a relay per phase
    • IP20 – dry board only
    • The manufacturer does not publish a full datasheet – parameters per supplier specification

    Safety and installation notes

    • Install only after disconnecting the supply and checking that no voltage is present; work must be done by a qualified electrician.
    • Upstream – a circuit breaker with a current not higher than the relay's rated current.
    • Do not swap phase and neutral.
    • Install the surge protective device (SPD) before the relay.
    • For compressors set a switch-on delay of at least 3 min.

    Quick selection guide

    1F
    63 A
    U> 230–300 V
    U< 160–210 V
    Suitable when you need:
    • to protect an apartment, house or circuit against a broken neutral
    • to protect a boiler, fridge, electronics
    • to see the mains voltage
    Check before use:
    • main circuit breaker current ≤ 63 A
    • whether a surge protective device (SPD) is installed
    Important reminder: a voltage relay does not replace a surge protective device, a circuit breaker or an RCD.

    FAQ

    Does the relay protect against lightning?
    No – a surge protective device (SPD) protects against lightning impulses.
    What current should I choose?
    The relay's rated current must be at least that of the upstream circuit breaker – the ESYRVP-4 suits a breaker up to 63 A.
    What switch-on delay should I set?
    For compressors at least 3 min; 10–30 s is enough for electronics and lighting.
    Why does the relay trip often?
    Most likely the limits are too narrow for a weak network – measure the mains voltage first.
    Is it suitable for a three-phase house?
    Yes – a relay is installed on each phase supplying the protected equipment, or choose a three-phase relay.
    Does the relay replace an RCD?
    No – only a residual current device (RCD) protects people from electric shock.

    Single-phase voltage relay | 1F | 63 A | U> 230–300 V | U< 160–210 V | DIN | ESYRVP-4

    ESYRVP-4 – protection against a broken neutral, overvoltage and undervoltage for a single-phase circuit.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Single-phase voltage relay | 1F | 63 A | U> 270 V | U< 170 V | DIN | ESAVP-63
    Code: ESAVP-63

    The ESAVP-63 is a single-phase digital voltage relay for DIN-rail mounting in a distribution board.

    Price 32.50 € VAT incl.
    ( 26.86 € VAT excl. )
    Terminal clamp | electrical wire connector | universal | 2x0.2-4mm² | for all wire types | WAGO | 221-412 | 4050821808435
    Code: WAGO 221-412

    The WAGO 221-412 connector is one of the most popular and reliable electrical wire connection solutions in the world. It is designed for fast, safe, and professional connection of various types of copper conductors without the need for additional tools.

    Thanks to the patented CAGE CLAMP® technology and convenient orange levers, this connector allows quick connection of solid, stranded, and flexible conductors. The transparent housing enables visual inspection of the connection quality, while its compact dimensions allow easy installation in junction boxes, distribution boards, luminaires, and various automation equipment.

    The WAGO 221 series is widely used in residential, commercial, and industrial applications where reliable, standards-compliant, and long-lasting wire connections are required. 

    Price 0.30 € VAT incl.
    ( 0.25 € VAT excl. )
    Modular | Digital Voltage Monitoring Relay | 1F | 63A | 230V | DIN | ETVPS1-63C
    Code: ETVPS1-63C
    This relay is designed to protect single-phase 230 V electrical installations and connected devices from overvoltage, undervoltage, and overcurrent. It is a practical solution for homes, workshops, farm facilities, technical rooms, and electrical panels where automatic monitoring of network parameters is required.
    Price 30.25 € VAT incl.
    ( 25.00 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information