Products catalog

  • Industrial switched interlocked socket | 1×16 A 5P 400 V 6h | surface-mounted, horizontal | IP54 | IK08 | Famatel 25120

    Code: 25120
    Barcode: 8429760281498

    Surface-mounted Famatel 25120 CEE 16 A 5P (3P+N+PE) 400 V 6h socket with switch and mechanical interlock, horizontal layout. IP54, IK08, padlockable switch. No protective devices – breaker and 30 mA RCD in the board.

  • Industrial switched interlocked socket | 1×16 A 5P 400 V 6h | surface-mounted, horizontal | IP54 | IK08 | Famatel 25120

    Famatel 25120 is a surface-mounted industrial CEE 16 A 5P 400 V socket with an integrated switch and mechanical interlock in a horizontal enclosure. It is fixed to a wall or structure. The plug is locked while the switch is ON, and once the plug is removed the switch is locked.

    Key point:
    Pulling a three-phase plug under load draws an arc and burns the contacts. In this socket the plug cannot be removed while the switch is ON, and the switch cannot be turned on without a plug. The IP54, IK08 enclosure suits workshops, garages and sheltered outdoor locations.
    Socket
    1×CEE 16 A 5P 400 V 6h
    Protection
    IP54, IK08
    Interlock
    mechanical, with switch
    Mounting
    surface, horizontal

    How it works

    The socket is supplied in its own enclosure and fixed to a wall or structure. The supply cable enters the enclosure and the conductors are connected to screw terminals.

    After the plug is inserted and the switch set to ON, the plug is locked and cannot be withdrawn. With the switch OFF the plug can be removed, after which the switch is locked.

    The switch can be padlocked in the ON or OFF position (the manufacturer recommends ON only for special applications). There are no protective devices in the socket – the breaker and RCD are in the board.

    Why choose Famatel 25120?
    Instead of a separate socket and a separate switch you get one product in which switching is tied to the plug. This reduces contact burning and risk when non-electricians connect a compressor, concrete mixer or workshop machine.

    Technical specifications

    Product type Surface-mounted industrial socket with switch and mechanical interlock (horizontal layout)
    Manufacturer / model Famatel / 25120
    Socket CEE 16 A, 5P (3P+N+PE), 6h
    Rated voltage 400 V (380–415 V), 50/60 Hz
    Protective devices none (no breaker, RCD or fuses)
    Degree of protection IP54 (splash-proof)
    Impact resistance IK08
    Materials ABS body, PA6 contact carrier, nickel-plated brass contacts
    Terminals screw
    Interlock mechanical; padlockable in ON and OFF
    Insulation resistance / dielectric strength > 10 MΩ / 2.5 kV
    Glow-wire test 850 °C (live-part supports), 650 °C (other parts)
    Operating temperature −25…+40 °C
    Mounting surface, on a wall or structure
    Standards IEC/EN 60309-1, IEC/EN 60309-2; Low Voltage Directive 2014/35/EU

    Main functions

    • Mechanical interlock – the plug cannot be withdrawn while the switch is ON.
    • Integrated switch – equipment is switched on and off locally, not with the plug.
    • Switch locked without plug – an empty socket stays de-energised.
    • Padlock option – unauthorised switching can be prevented.
    • CEE 16 A 5P 6h – standard 400 V connection to EN 60309-2.
    • IP54 and IK08 – against dust, splashes and moderate impacts.
    • Surface enclosure – no separate mounting box needed.

    How does it differ from similar products?

    Famatel 26012 (8484) Same 16 A interlocked socket, but in a vertical enclosure.
    Famatel 25127 (8482) 32 A version – for higher-power equipment.
    SEZ BZS1653 (583) SEZ 16 A socket with switch-disconnector and interlock – alternative from another manufacturer.
    Scame 405.3287 (2382) 32 A switched interlocked socket, IP66/IP67 – for wash-down and outdoor locations.

    Where is it used?

    • Workshops and production halls
    • Garages and car services
    • Warehouses and logistics centres
    • Farm and utility buildings
    • Connection points for compressors, pumps and fans
    • Construction sites (supplied from a site board)
    • Sheltered outdoor locations

    Use by need

    For beginners.
    This is a switched socket: insert the plug first, then switch on. Remove the plug only after switching off.
    For experienced installers.
    Screw terminals, nickel-plated brass contacts. Seal the cable entry and check phase rotation for three-phase motors.
    For power engineers / designers.
    The product complies with IEC/EN 60309-1/-2. There are no protective devices – provide the line breaker (max 16 A) and a 30 mA RCD in the board.

    Practical use

    In a workshop a Famatel 25120 is installed next to the workstation, supplied with 5×2.5 mm² cable from a board with a 16 A breaker and 30 mA RCD (cable size confirmed by the designer for length and installation method). It feeds a compressor, concrete mixer or workshop machine: the operator inserts the plug, switches on, and when finished switches off and only then removes the plug.

    Pros / advantages

    • Mechanical interlock – the plug is never pulled under load
    • Integrated switch to control the socket
    • IP54 and IK08
    • Padlockable in ON and OFF
    • Surface enclosure – no separate box needed
    • Glow-wire test 850 °C

    Cons / limitations

    • No breaker or RCD – protection must be in the board.
    • IP54 – not for water jets; for wash-down areas choose Scame 405.3287 (2382), IP66/IP67.
    • Single socket only – for several loads choose a combined socket box.
    • Dimensions and switch utilisation category are not given in the manufacturer data – check before design.

    Safety and installation notes

    • ⚡ Installation and connection by a qualified electrician only, with the supply disconnected.
    • ⚡ Protect the line with a circuit breaker sized to the cable (max 16 A) and a 30 mA RCD – the socket has no protective devices.
    • This is a 400 V three-phase socket: it must not be supplied or used from a single-phase line.
    • The switch controls the socket only and does not replace the line isolating device in the board.
    • On construction sites supply the socket only from a site distribution board (HD 60364-7-704).
    • IP54 applies only with the lid closed or a suitable plug inserted and the cable entry sealed.
    • Do not bypass the interlock or pull the plug with the switch ON.

    Quick selection guide

    CEE 16 A 5P 6h
    400 V, 50/60 Hz
    IP54, IK08
    Switch and interlock
    Suitable when you need:
    • to connect three-phase equipment safely without arcing at the plug
    • local on/off switching at the machine
    • the option to padlock the socket
    Check before choosing:
    • that the equipment plug is CEE 16 A 5P 6h
    • that the board has a breaker (max 16 A) and a 30 mA RCD
    • that a horizontal enclosure suits your mounting location
    • that the location is not hit directly by water jets
    Important reminder: The socket has no breaker, RCD or fuses – line protection is installed in the board. The switch controls the socket only and does not replace the line isolating device.
    ☝ Elsprendimai.eu recommends:

    FAQ

    How does the interlock work?
    After the plug is inserted and the switch set to ON, the plug is locked. With the switch OFF the plug can be removed, and then the switch is locked.
    Is there a breaker or RCD inside?
    No. Protection is a breaker (max 16 A) and a 30 mA RCD in the board.
    Can it be connected to a single-phase line?
    No. This is a 400 V 5P socket for three-phase equipment; single-phase equipment needs a 230 V socket.
    Can it be locked?
    Yes, the switch can be padlocked in the ON or OFF position.
    Is it suitable outdoors?
    IP54 protects against splashes; outdoors install it under a shelter and seal the cable entry.
    What is the difference between horizontal and vertical?
    The enclosure layout differs; electrical ratings are the same. This model has a horizontal layout.

    Sources: Famatel product page and technical data sheet (25116 family), declaration of conformity listing code 25120; distributor page suministroselectricos.es for 25120. Checked 2026-10-20.

    Famatel 25120 – 16 A 5P switched interlocked socket, IP54

    Surface-mounted Famatel 25120 CEE 16 A 5P 400 V socket with switch and mechanical interlock, IP54, IK08 – for workshops, garages and warehouses.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Cable | rubber | 3x2.5 | 450/750 V AC | flexible | H07RN-F 3x2.5
    Code: H07RN-F 3x2.5

    Flexible heavy-duty rubber cable H07RN-F with EPR insulation and polychloroprene (PCP) sheath. Withstands chemical, mechanical and thermal stress – for construction sites, ports, drainage, water treatment, industrial cold stores and mobile equipment.

    Price is per 1 m.

    Price 2.25 € VAT incl.
    ( 1.86 € VAT excl. )
    Cable gland with locknut and gasket | PG7 | for cable Ø3–6.5 mm | grey | IP68 | 4772124000810
    Code: 00810

    Plastic PG7 cable gland with locknut and gasket for routing Ø3–6.5 mm round cables into distribution boards and junction boxes. Provides IP68 sealing when correctly installed.

    Price 0.20 € VAT incl.
    ( 0.17 € VAT excl. )
    Industrial socket box | 4×16 A 5P 400 V | with holder | IP44 | SEZ ROS 1601 D
    Code: ROS1601 4xIE1653-

    SEZ socket box with 4×CEE 16 A 5P outlets, IP44 (outlets IP54), with a holder for portable use. No MCBs or RCD inside – protection is installed in the supply board.

    Price 27.71 € VAT incl.
    ( 22.90 € VAT excl. )
    Single-cable membrane entry flange | for Ø86 mm hole | cable Ø55–70 mm | flange Ø123.1 mm | grey | IP67 | HT Hi Tech Polymers | HTX-1
    Code: Sandariklis HTX-1

    HTX-1 is a membrane entry flange for one thick power cable Ø55–70 mm. It fits a round Ø86 mm hole in the enclosure wall, flange diameter Ø123.1 mm. Sealing rating is IP67 according to the latest manufacturer's sheet.

    Price 21.78 € VAT incl.
    ( 18.00 € VAT excl. )
    Terminal | connector paste for contacts | reduces oxidation | 35.3g | WAGO | ALU PLUS | 249-130 | for connecting aluminium and copper wires
    Code: 4017332133890

    Contact paste designed to protect aluminum conductors from oxidation and ensure a reliable electrical connection. This special paste allows aluminum and copper conductors to be safely and efficiently connected within the same connector, making it particularly useful when renovating older electrical installations where aluminum wiring is commonly found.

    Aluminum naturally oxidizes, and the resulting oxide layer increases contact resistance, causes connection heating, and may become a source of electrical faults. By using WAGO ALU-PLUS, the oxidation layer is reduced, electrical conductivity is improved, and the service life of the connection is significantly extended. 

    Price 2.83 € VAT incl.
    ( 2.34 € VAT excl. )
    Wire connector | universal electrical terminal | 5x0.2–4mm² | for all conductor types | WAGO | 221-415 | 4055143234658
    Code: WAGO 221-415

    WAGO 221-415 is a universal 5-conductor wire connector designed for fast and reliable connection of different conductor types. It is suitable for 0.2–4 mm² conductors, including solid, stranded and flexible wires. The transparent housing and lever design make wire insertion, inspection and reconnection easy.

    Price 0.57 € VAT incl.
    ( 0.47 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information